Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz Dent J ; 34(2): 67-74, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37194858

RESUMO

The objective of this work was to evaluate the mechanical performance of Z350 resin composite modified with Bombyx mori cocoons silk nanoparticles for dental applications. Four experimental groups were analyzed G0% = Filtek Z350 resin composite (control); G1% = Filtek Z350 with 1% of silk nanoparticles; G3% = Filtek Z350 with 3% of silk nanoparticles; G5% = Filtek Z350 with 5% of silk nanoparticles. It was employed scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, 3-point flexural strength test, Knoop hardness test, and surface roughness. From 3-point flexural strength tests the control group presented the best results G0% = 113.33 MPa (±23.73). The higher flexural modulus was shown by groups G3% = 29.150 GPa (±5.191) and G5% = 34.101 GPa (±7.940), which are statistically similar. The Knoop microhardness test has shown statistical difference only among the G3% group between the top 80.78 (± 3.00) and bottom 68.80 (±3.62) and no difference between the groups. The roughness test presented no statistical difference between the groups. The incorporation of silk nanoparticles reduced the flexural strength of Z350 resin composite. The surface roughness and microhardness tests showed no changes in any of the groups studied.


Assuntos
Bombyx , Nanopartículas , Animais , Seda , Dureza , Teste de Materiais , Resinas Compostas/química , Propriedades de Superfície , Materiais Dentários/química
2.
Braz. dent. j ; 34(2): 67-74, Mar.-Apr. 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439572

RESUMO

Abstract The objective of this work was to evaluate the mechanical performance of Z350 resin composite modified with Bombyx mori cocoons silk nanoparticles for dental applications. Four experimental groups were analyzed G0% = Filtek Z350 resin composite (control); G1% = Filtek Z350 with 1% of silk nanoparticles; G3% = Filtek Z350 with 3% of silk nanoparticles; G5% = Filtek Z350 with 5% of silk nanoparticles. It was employed scanning electron microscopy, energy dispersive X-ray spectroscopy, X-ray diffraction, 3-point flexural strength test, Knoop hardness test, and surface roughness. From 3-point flexural strength tests the control group presented the best results G0% = 113.33 MPa (±23.73). The higher flexural modulus was shown by groups G3% = 29.150 GPa (±5.191) and G5% = 34.101 GPa (±7.940), which are statistically similar. The Knoop microhardness test has shown statistical difference only among the G3% group between the top 80.78 (± 3.00) and bottom 68.80 (±3.62) and no difference between the groups. The roughness test presented no statistical difference between the groups. The incorporation of silk nanoparticles reduced the flexural strength of Z350 resin composite. The surface roughness and microhardness tests showed no changes in any of the groups studied.


Resumo O objetivo deste trabalho foi avaliar o desempenho mecânico da resina composta Z350 modificada com nanopartículas de seda Bombyx mori cocoons para aplicações odontológicas. Quatro grupos experimentais foram analisados: G0%) Resina Z350 apenas (grupo controle); G1%) Reforço com 1% de nanopartículas de seda; G3%) Reforço com 3% de nanopartículas de seda; e G5%) Reforço com 5% de nanopartículas de seda. Foi empregado microscopia eletrônica de varredura, espectroscopia de energia dispersiva de raios X, difração de raios X, teste de resistência à flexão de 3 pontos, teste de dureza Knoop e rugosidade superficial. Nos testes de resistência à flexão de 3 pontos o grupo controle apresentou melhores resultados G0% = 0.113 GPa (±0.024). O maior módulo de flexão foi demonstrado pelos grupos G3% = 29.151GPa (±5.191) e G5% = 34.102 GPa (±7.94), que são estatisticamente semelhantes. O teste de microdureza Knoop mostrou diferença estatística apenas entre o grupo G3% entre os 80.78 superiores (± 3.00) e os 68.80 inferiores (±3.62). Não há diferença entre os grupos. O teste de rugosidade não apresentou diferença estatística entre os grupos. A incorporação de nanopartículas de seda reduziu a resistência à flexão da resina composta Z350. Os testes de rugosidade superficial e microdureza não apresentaram alterações em nenhum dos grupos estudados.

3.
Braz. dent. j ; 33(3): 99-108, July-Sept. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1384038

RESUMO

Abstract This study showed the synthesis of Glass ionomer cements (GIC) modified with calcium phosphate nanoparticles (nCaP). The nCaP/GIC were submitted to mechanical compression and diametral tensile tests. The biocomposite were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR). Cytotoxicity and cell viability tests were performed on the human bone marrow mesenchymal stem cells using a 3-(4,5-dimethylthiazol-2yl)2,5-diphenyl- tetrazolium-bromide assay and LIVE/DEAD assays. Statistically significant differences were observed for mechanical properties (Kruskal-Wallis, p<0.001), nCaP/GIC showed higher resistance to compression and diametral traction. The SEM analyses revealed a uniform distribution nCaP in the ionomer matrix. The EDX and XRD results indicated that hydroxyapatite and calcium β-triphosphate phases. The FTIR spectra revealed the asymmetric band of ν3PO43- between 1100-1030cm-1 and the vibration band associated with ν1PO43- in 963cm-1 associated with nCaP. The nCaP/GIC presented response to adequate cell viability and non-cytotoxic behavior. Therefore, the new nCaP/GIC composite showed great mechanical properties, non-cytotoxic behavior, and adequate response to cell viability with promising dental applications.


Resumo Este estudo apresenta a síntese de cimentos de ionômero de vidro (GIC) modificados com nanopartículas de fosfato de cálcio (nCaP). Os nCaP / GIC foram submetidos a ensaios mecânicos de compressão e tração diametral. Os biocompósitos foram caracterizados por microscopia eletrônica de varredura (MEV), espectroscopia de energia dispersiva de raios-X (EDX), difração de raios-X (XRD) e espectroscopia de infravermelho com transformada de Fourier (FTIR). Os testes de citotoxicidade e viabilidade celular foram realizados em células-tronco mesenquimais da medula óssea humana usando um ensaio de 3- (4,5-dimetiltiazol-2-il) 2,5-difeniltetrazólio-brometo e ensaios LIVE / DEAD. Diferenças estatisticamente significativas foram observadas para as propriedades mecânicas (Kruskal-Wallis, p <0,001), nCaP / GIC apresentou maior resistência à compressão e tração diametral. As análises de SEM revelaram uma distribuição uniforme de nCaP na matriz do ionômero. Os resultados de EDX e DRX indicaram fases de hidroxiapatita e β-trifosfato de cálcio. Os espectros de FTIR revelaram a banda assimétrica de ν3PO4 3- entre 1100-1030cm-1 e a banda de vibração associada a ν1PO4 3- em 963cm-1 associada a nCaP. O nCaP / GIC apresentou resposta adequada à viabilidade celular e comportamento não citotóxico. Portanto, o novo compósito nCaP / GIC apresentou ótimas propriedades mecânicas, comportamento não citotóxico e resposta adequada à viabilidade celular com promissoras aplicações odontológicas.

4.
Braz Dent J ; 33(3): 99-108, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35766723

RESUMO

This study showed the synthesis of Glass ionomer cements (GIC) modified with calcium phosphate nanoparticles (nCaP). The nCaP/GIC were submitted to mechanical compression and diametral tensile tests. The biocomposite were characterized by scanning electron microscopy (SEM), energy-dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD) and Fourier-transform infrared spectroscopy (FTIR). Cytotoxicity and cell viability tests were performed on the human bone marrow mesenchymal stem cells using a 3-(4,5-dimethylthiazol-2yl)2,5-diphenyl- tetrazolium-bromide assay and LIVE/DEAD assays. Statistically significant differences were observed for mechanical properties (Kruskal-Wallis, p<0.001), nCaP/GIC showed higher resistance to compression and diametral traction. The SEM analyses revealed a uniform distribution nCaP in the ionomer matrix. The EDX and XRD results indicated that hydroxyapatite and calcium ß-triphosphate phases. The FTIR spectra revealed the asymmetric band of ν3PO43- between 1100-1030cm-1 and the vibration band associated with ν1PO43- in 963cm-1 associated with nCaP. The nCaP/GIC presented response to adequate cell viability and non-cytotoxic behavior. Therefore, the new nCaP/GIC composite showed great mechanical properties, non-cytotoxic behavior, and adequate response to cell viability with promising dental applications.


Assuntos
Nanocompostos , Nanopartículas , Durapatita/química , Cimentos de Ionômeros de Vidro/química , Cimentos de Ionômeros de Vidro/toxicidade , Humanos , Teste de Materiais , Nanocompostos/química , Nanocompostos/toxicidade , Nanopartículas/química
5.
Biosci. j. (Online) ; 38: e38055, Jan.-Dec. 2022. ilus, tab
Artigo em Inglês | LILACS | ID: biblio-1396425

RESUMO

To evaluate the effect of ellagic acid on the inhibition of matrix metalloproteinase by analyzing the quality of the adhesive interface with bond strength measures in periods of 24 hours and six months of storage. Method: 40 healthy human third molars were prepared with class I cavities (5x4x3mm). The teeth were divided into four experimental groups: Group 1- without application of ellagic acid and storage time of 24 hours; Group 2- with ellagic acid/24 hours; G3- without ellagic acid/six months; Group 4- with ellagic acid/six months. Then, the cavities were restored with Single Bond Universal adhesive and Z350 composite resin, with and without the previous application of ellagic acid. Subsequently, hourglass-shaped specimens were obtained and subjected to the bond strength (BS) test (n = 10) in a universal testing machine. The bond test was performed after 24 hours and six months of storage. For the standard evaluation (n = 3) the samples were infiltrated with silver nitrate and placed in a developing solution for analysis in a Scanning Electron Microscope (SEM). The data obtained were analyzed with the Kruskal-Wallis non-parametric test, showing a statistically significant difference. Results: The highest bond strength values were found for the 24-hour groups followed by the groups with six months of storage. For nano-infiltration, groups G1 and G2 showed lower infiltration than groups G3 and G4. Conclusion: The previous application of ellagic acid did not affect the BS of the adhesive interface of the adhesive system analyzed, regardless of storage time.


Assuntos
Metaloproteinases da Matriz , Cimentos Dentários , Ácido Elágico
6.
Int. j. odontostomatol. (Print) ; 14(4): 658-663, dic. 2020. tab
Artigo em Inglês | LILACS | ID: biblio-1134554

RESUMO

ABSTRACT: Orthodontic accessories bonding in tooth enamel has been a critical step since the introduction of direct bonding techniques due to the importance of bracket stability. The aim of this study was to evaluate adhesion strength of different adhesive systems used for bracket bonding on dental surface. The present in vitro study was made from the analysis of shear strength of steel and ceramic brackets bonding with six different types of orthodontic adhesives. The brackets were bonded to 120 human extracted first premolar teeth with Orthocem®, Orthocem® + Ambar Universal® primer, Orthobond Plus®, Biofix®, Transbond XT®, Ortholink VLC®. Shear strength tests were performed on a universal testing machine EZ-Test-Shimadzu® and the data were analyzed using ANOVA test with Post-Hoc Bonferroni and 95 % statistical significance (p <0.05). Transbond XT® and Ortholink VLC® resin values showed greater shear resistance for steel brackets bonding and Transbond XT® and Orthobond Plus® adhesives showed better adhesion results for ceramic brackets bonding.


RESUMEN: La unión de accesorios de ortodoncia en el esmalte dental ha sido un paso crítico desde la introducción de las técnicas de unión directa debido a la importancia de la estabilidad del soporte. El objetivo de este estudio fue evaluar la fuerza de adhesión de diferentes sistemas adhesivos utilizados para la unión de brackets en la superficie dental. El presente estudio in vitro se realizó a partir del análisis de la resistencia al corte de brackets de acero y de cerámica unidos con seis tipos diferentes de adhesivos de ortodoncia. Los brackets se unieron a 120 primeros premolares extraídos con los adhesivos Orthocem®, Orthocem® + Ambar Universal® primer, Orthobond Plus®, Biofix®, Transbond XT®, Ortholink VLC®. Las pruebas de resistencia al corte se realizaron en una máquina de prueba universal EZ-Test-Shimadzu® y los datos se analizaron usando la prueba ANOVA con Bonferroni Post-Hoc y 95 % de significación estadística (p <0,05). Los valores de resina Transbond XT® y Ortholink VLC® mostraron una mayor resistencia al corte para la unión de brackets de acero y los adhesivos Transbond XT® y Orthobond Plus® mostraron mejores resultados de adhesión para la unión de brackets cerámicos.


Assuntos
Humanos , Colagem Dentária/métodos , Braquetes Ortodônticos , Cimentos Dentários , Ortodontia , Aço Inoxidável , Teste de Materiais , Cerâmica , Cimentos de Resina , Resistência ao Cisalhamento
7.
J. health sci. (Londrina) ; 21(1)30/04/2019.
Artigo em Inglês | LILACS | ID: biblio-995924

RESUMO

The aim of this study was to evaluate the surface roughness of a silorane and methacrylate-based composite resins subjected to different finishing/polishing techniques. Twelve disk specimens were prepared from each composite resin: P90®, Z350® and Charisma, divided into 12 groups according to the finishing/polishing technique: no finishing/polishing (control); finishing with 1112 FF diamond burs; finishing with 1112 FF diamond burs associated to Enhance/Pogo; finishing with 1112 FF diamond burs associated to Enhance/Pogo/Polishing/Poli I and II pastes/Fotogloss. After initial readouts of surface roughness, the specimens were subjected to mechanical cycling (1.200.000 cycles) and immediately subjected to final roughness readouts. Surface roughness means was statistically analyzed by ANOVA and Tukey-Kramer test (α=0.05). SEM images were realized after finishing/polishing and after mechanical cycling. The P90 composite showed surface roughness values similar to other investigated composites. However, significant difference was observed in finishing/polishing techniques. The diamond burs group showed the highest surface roughness differing from the other composite resins (α < 0.05). Enance/Pogo showed the lowest results, which presented no difference compared to the polishing paste group (α > 0.05). The low-shrink posterior restorative showed similar surface roughness when compared to dimethacrylate composite resins and suitable to posterior restorations. (AU).


O objetivo deste estudo foi avaliar a rugosidade superficial de resinas compostas à base silorano e metacrilato submetidas a diferentes técnicas de acabamento/polimento. Foram preparadas 12 amostras de disco de cada resina composta: P90®, Z350® e Carisma, divididas em 12 grupos de acordo com a técnica de acabamento / polimento: sem acabamento / polimento (controle); acabamento com ponta diamantada 1112 FF; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo; acabamento com ponta diamantada 1112 FF associada a Enhance / Pogo / Polishing / Pastas Poli I e II / Fotogloss. Após as leituras iniciais da rugosidade da superfície, os espécimes foram submetidos a ciclos mecânicos (1.200.000 ciclos) e submetidos imediatamente a leituras de rugosidade final. As medias de rugosidade superfícial foram analisadas estatisticamente por ANOVA e teste de Tukey-Kramer (α = 0,05). As imagens de MEV foram realizadas após o acabamento / polimento e após a ciclagem mecânica. O compósito P90 mostrou valores de rugosidade superficial semelhantes a outros compósitos investigados. Tough, mostrou diferença significativa nas técnicas de acabamento / polimento. O grupo de pontas damantadas apresentou maior rugosidade superficial que diferiu das outras resinas compostas (α <0,05). Enance / Pogo mostrou os menores resultados, que não apresentaram diferença em relação ao grupo de pasta de polimento (α> 0,05). O material restaurador posterior de baixa contração apresentou rugosidade superficial semelhante quando comparado as resinas compostas de dimetacrilato e são restaurações adequadas para região posterior. (AU).

8.
Braz Oral Res ; 32: e95, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30231170

RESUMO

The aim of the present study was to evaluate the prevalence and impact of malocclusion on oral health-related quality of life (OHRQoL) among schoolchildren aged 8 to 10 years and their parents in Diamantina, a town in the southeast of Brazil. A cross-sectional study was conducted with a sample of 390 randomly selected children who were subjected to a clinical oral examination. The Dental Aesthetic Index was used to diagnose malocclusion and the need for orthodontic treatment. The Child Perceptions Questionnaire (CPQ (8-10)) was used to evaluate the impact of malocclusion on OHRQoL. The children's parents answered the Brazilian Economic Criterion Questionnaire for the socioeconomic classification. Data analysis involved the nonparametric Kruskal-Wallis test and Spearman's correlation coefficients. The variables were grouped into a hierarchy of categories ranging from distal to proximal determinants. Poisson regression analysis with robust variance was performed at each level to correlate the total CPQ (8-10) score with the independent variables. The prevalence of malocclusion was 78.7%. Crossbite remained significantly associated with a negative impact on OHRQoL (PR = 1.28; 95%CI:1.17-1.39; p < 0.001). The prevalence of malocclusion was high in the sample investigated and exerted a negative impact on OHRQoL.


Assuntos
Má Oclusão/epidemiologia , Má Oclusão/fisiopatologia , Saúde Bucal/estatística & dados numéricos , Qualidade de Vida , Brasil/epidemiologia , Criança , Estudos Transversais , Cárie Dentária/epidemiologia , Cárie Dentária/fisiopatologia , Estética Dentária , Feminino , Humanos , Índice de Necessidade de Tratamento Ortodôntico , Masculino , Prevalência , Índice de Gravidade de Doença , Fatores Socioeconômicos , Estatísticas não Paramétricas , Inquéritos e Questionários
9.
Braz. j. oral sci ; 16: e17059, jan.-dez. 2017. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-883924

RESUMO

The aim of this study was to evaluate how acid-etching of the cavosurface enamel in Class I resin composite restorations influences the bond strength to the pulpal wall and the restoration, Knoop microhardness and nanoleakage after thermomechanical aging. For this research 76 fresh human molars were selected and restored with Silorane or Clearfil SEBond/Z350XT composite divided in 4 groups (Silorane system restored with or without enamel cavosurface acid-etching and Clearfil SEBond/Z350XT with or without enamel cavosurface acid-etching). To induce artificial aging, samples were subjected to thermomechanical cycling through 200,000 and thermal cycling between 5 and 55 °C with 30 second filling and 15-second drainage steps. Microhardness and microtensile bond strength were evaluated in 32 teeth (n=8) each and nanoleakage evaluation was performed in 12 teeth (n=3). Samples restored by Clearfil SEBond/Z350 XT without cavosurface acid-etching showed significantly lower microtensile bond strength results. The resin composite Z350XT presented higher values of Knoop microhardness. It was observed little or no infiltration for Silorane groups and moderate infiltration for Clearfil SE Bond groups. Acid-etching of the cavosurface enamel during restoration procedure with Clearfil Se Bond resulted in a stronger bond after thermomechanical cycling. Silorane groups showed less infiltration than Clearfil SE Bond groups (AU)


Assuntos
Humanos , Adesivos , Resinas Compostas , Preparo da Cavidade Dentária , Resinas de Silorano , Resistência à Tração
10.
Microsc Res Tech ; 80(8): 943-949, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28488772

RESUMO

AIM: Evaluate the composite-to-enamel bond after passive or active application of self-etching primer systems on polished or pre-etched enamel with phosphoric acid. MATERIALS AND METHODS: Two self-etch adhesives systems (SEAS) were used: Clearfil SE Bond and Easy Bond. Third human molars were divided into 8 groups (N = 10). The crown of each tooth was sectioned into halves and the mesial/distal surfaces were used. The adhesives were actively or passively applied on enamel with or without prior phosphoric-acid etching. Resin composite cylinders were built after adhesive application. After stored in relative humidity for 24 hr/37°C the specimens were subjected to microshear test in universal testing a machine at a crosshead speed of 0.5 mm/minute. The results were analyzed with three-way ANOVA and the Tukey test. The enamel-etching pattern was evaluated under SEM. RESULTS: The 2-step SEAS system presented significantly higher adhesive bond strength means (47.37 MPa) than the 1-step (36.87 MPa). A poor enamel- etching pattern was observed in active mode showing irregular and short resin tags, however there was not compromised the bond strength. CONCLUSION: Active or passive application produced similar values of bond strength to enamel regardless of enamel pretreatment and type of SEAS.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA