Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 57
Filtrar
1.
Int J Dent ; 2024: 1454079, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38966138

RESUMO

Objective: This study aimed to perform a histological evaluation of teeth diagnosed with internal root resorption. Materials and Methods: A descriptive study involved the examination of 50 human teeth extracted due to an unfavorable prognosis for retention in the oral cavity. Teeth were preserved in 10% buffered formalin and subsequently subjected to the decalcification process. Masson-Goldner staining was applied for comprehensive histological assessment. Results: In all the 50 teeth examined, resorption gaps within the dentin tissue were identified, accompanied by the presence of reparative cells in the vicinity of these cavities. Marked structural loss and dentin fragmentation were evident, with regions exhibiting fissures and an absence of dentinal tubules. Conclusions: The histological evaluation of 50 teeth diagnosed with internal dental resorption revealed significant structural alterations, including resorption lacunae, the presence of multinucleated osteoclast-like cells, and reparative connective tissue. These findings highlight the complex and multifaceted nature of internal dental resorption. These histological insights provide a deeper understanding of the pathological processes involved in internal dental resorption and underscore the necessity for early detection and intervention to mitigate tooth loss and preserve dental health.

3.
Dent J (Basel) ; 12(5)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38786518

RESUMO

The integration of wireless sensors with artificial intelligence could represent a transformative approach in restorative dentistry, offering a sophisticated means to enhance diagnostic precision, treatment planning, and patient outcomes. This systematic review was conducted to pinpoint and assess the efficacy of wireless sensors in restorative dentistry. The search methodology followed the guidelines outlined by PRISMA and involved the utilization of prominent scientific databases. Following the final phase of evaluating eligibility, the systematic review included six papers. Five experiments were conducted in vitro, while one was a randomized clinical trial. The investigations focused on wireless sensors for cavity diagnosis, toothbrush forces, facial mask applications, and physiological parameter detection from dental implants. All wireless sensors demonstrated efficacy in achieving the objectives established by each study and showed the validity, accuracy, and reproducibility of this device. The investigations examined in this systematic review illustrate the potential of wireless sensors in restorative dentistry, especially in the areas of caries detection, dental implant systems, face masks, and power brushes. These technologies hold promise for enhancing patient outcomes and alleviating the workload of dental practitioners.

4.
Biomed Res Int ; 2024: 3930130, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38803514

RESUMO

The presence of positive bile culture during intraoperative procedures has been associated with elevated morbidity and mortality rates in hepatobiliopancreatic surgeries, contributing to increased healthcare expenditures. However, the precise impact of bactobilia on the development of postoperative complications remains uncertain due to existing disparities in the published literature. In this retrospective cohort study, we assessed 137 patients who underwent major hepatobiliopancreatic surgery to examine the relationship between intraoperative bile culture outcomes and subsequent postoperative infectious complications. Among patients with bactobilia, a significant 35.1% exhibited systemic or local infectious complications, whereas only 11.1% of those with negative culture results experienced any infectious complications (p = 0.002). Similarly, a notable difference was observed in the incidence of surgical site infections, with 24.3% in the bactobilia group compared to 7.9% in the negative culture group (p = 0.01). A total of 74 monomicrobial cultures with microbiological growth were isolated, predominantly featuring Gram-negative microorganisms, primarily Enterobacteriaceae in 49 cultures. Escherichia coli was identified in 37.8% of positive cultures, while Klebsiella pneumoniae was evident in 21.6%. Gram-positive microorganisms were present in 10 cultures, with Enterococcus emerging as the prevailing species. The logistic regression model identified a positive bile culture as an independent factor significantly associated with infection development (OR: 2.26; 95% confidence interval: 1.23-11; p = 0.02). Considering the limitations of the study, these findings underscore the critical importance of conducting bile cultures during the intraoperative phase to enable vigilant monitoring and prompt management of infectious complications.


Assuntos
Bile , Complicações Pós-Operatórias , Humanos , Masculino , Feminino , Bile/microbiologia , Estudos Retrospectivos , Pessoa de Meia-Idade , Idoso , Complicações Pós-Operatórias/microbiologia , Complicações Pós-Operatórias/epidemiologia , Infecção da Ferida Cirúrgica/microbiologia , Infecção da Ferida Cirúrgica/epidemiologia , Adulto , Escherichia coli/isolamento & purificação
5.
J Oral Rehabil ; 51(7): 1337-1347, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38616519

RESUMO

BACKGROUND: The noteworthy correlation between bite force and masticatory performance emphasizes its significance as a meaningful and objective method for assessing oral function. Furthermore, in the study of bruxism, the measurement of intraoral bite force assumes critical importance. Given the importance of assessing occlusal forces and bite force, this systematic review aims to assess the efficacy of wireless sensors in measuring these forces. METHODS: The search methodology employed in this systematic review adhered to the guidelines outlined by PRISMA. The strategy involved the exploration of various databases, including PubMed/MEDLINE, SCOPUS and SCIELO. An assessment tool was employed to evaluate the bias risk and study quality. RESULTS: This systematic review encompassed six prospective clinical studies involving a total of 89 participants. Wireless sensors for measuring occlusal forces and bite forces were predominantly employed in healthy adults or individuals with bruxism, along with children undergoing orthodontic treatment. All wireless sensors employed in the studies underwent validation and reproducibility assessments, affirming their reliability. The findings indicated that all wireless sensors exhibited efficacy in detecting occlusal forces and bite forces. CONCLUSION: Wireless sensors offer real-time monitoring of occlusal and bite forces, aiding in understanding force distribution and identifying bruxism patterns. Despite limited studies on their application, these sensors contribute to evolving insights. Integration into clinical practice requires careful consideration of factors like calibration and patient compliance. Ongoing research is crucial to address limitations and enhance the efficacy of wireless sensors in measuring occlusal and bite forces and managing bruxism.


Assuntos
Força de Mordida , Bruxismo , Tecnologia sem Fio , Humanos , Bruxismo/fisiopatologia , Bruxismo/diagnóstico , Tecnologia sem Fio/instrumentação , Reprodutibilidade dos Testes , Mastigação/fisiologia
6.
Orthod Craniofac Res ; 2024 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-38372469

RESUMO

OBJECTIVE: To evaluate the efficacy of microchips and 3D microsensors in the measurement of orthodontic forces. METHODS: Through September 2023, comprehensive searches were conducted on PubMed/MEDLINE, SCOPUS and SCIELO without restrictions. RESULTS: After removing duplicate entries and applying the eligibility criteria, 23 studies were included for analysis. All the studies were conducted in vitro, and slightly more than half of them were centred on evaluating orthodontic forces exerted by aligners. Eight utilized microchips as measurement tools, while the remaining studies made use of 3D microsensors for their assessments. In the context of fixed appliances, key findings included a high level of agreement in 3-dimensional orthodontic force detection between simulation results and actual applied forces. Incorporating critical force-moment combinations during smart bracket calibration reduced measurement errors for most components. Translational tooth movement revealed a moment-to-force ratio, aligning with the bracket's centre of resistance. The primary findings in relation to aligners revealed several significant factors affecting the forces exerted by them. Notably, the foil thickness and staging were found to have a considerable impact on these forces, with optimal force transmission occurring at a layer height of 150 µm. Furthermore, the type of material used in 3D-printing aligners influenced the force levels, with attachments proving effective in generating extrusive forces. Deliberate adjustments in aligner thickness were observed to alter the forces and moments generated. CONCLUSIONS: Microchips and 3D sensors provide precise and quantitative measurements of orthodontic forces in in vitro studies, enabling accurate monitoring and control of tooth movement.

7.
Orthod Craniofac Res ; 2024 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-38247223

RESUMO

OBJECTIVE: This study aims to utilize the finite element method (FEM) to compare the dentoalveolar and mandibular effects associated with anterior mandibular repositioning using AdvanSync® (ADV) and Twin Block (TB). METHODS: A patient with Class II skeletal malocclusion and mandibular retrognathism was selected. A TB appliance was subsequently applied. Computed Tomography (CT) scans were acquired at the beginning of treatment (T1) and 8 months later (T2). Concurrently, a numerical TB model was validated through FEM simulations, which were compared with the T2 results. The ADV appliance was virtually simulated to evaluate stress and deformation on the condyle, symphysis, first lower molar and lower central incisors. RESULTS: Both simulations demonstrated significant mandibular advancement. However, ADV led to less incisor proclination and more molar intrusion compared to TB. ADV exhibited increased stress in the lower molar area, while TB had higher stress in the lower incisor region. Stress and deformations in the condyle and mandibular symphysis were similar in both simulations, with the highest stress observed at the condylar neck and the lowest at the upper pole of the condylar head. CONCLUSIONS: Both appliances achieved similar levels of mandibular advancement, with greater proclination of the lower central incisors and more widespread distribution of stress and molar intrusion when using ADV compared to TB.

8.
Dent J (Basel) ; 11(11)2023 Oct 24.
Artigo em Inglês | MEDLINE | ID: mdl-37999009

RESUMO

Porphyromonas gingivalis, Tannerella forsythia, and Treponema denticola, collectively recognized as periodontopathogens within the red complex, have been extensively studied in clinical samples collected from individuals with periodontitis. A lab-on-a-chip (LOC) is a miniature mechanism that integrates various laboratory operations onto a single microchip or a small-scale platform. This systematic review evaluates the application of LOC technology in identifying microorganisms from the red complex. This study adhered to PRISMA recommendations, and the review process encompassed several databases. In the electronic search, a total of 58 reports were found, and ultimately, 10 studies were considered relevant for inclusion. All these studies described effective, rapid, and reliable LOC systems for detecting and amplifying P. gingivalis, T. forsythia, and T. denticola. Compared to traditional methods, the LOC approach demonstrated minimal reagent requirements. Additionally, the results indicated that the amplification process took approximately 2 to 8 min, while detection could be completed in as little as 2 min and 40 s, resulting in a total experimental duration of around 11 min. Integrating miniaturization, speed, accuracy, and automation within microchip platforms makes them promising tools for detecting and amplifying microorganisms associated with the red complex in periodontal diseases.

9.
Medicina (Kaunas) ; 59(10)2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37893437

RESUMO

Background and Objectives: Staphylococcus aureus is a prevalent bacterium capable of inducing various infections, including skin and soft tissue infections, bloodstream infections, pneumonia, and surgical site infections. The emergence of antimicrobial resistance in S. aureus, particularly methicillin-resistant S. aureus, has raised substantial concerns within global healthcare settings. Prior to antibiotic prescription, the ideal approach is antimicrobial susceptibility testing (AST); however, this is frequently perceived as excessively complex and time-intensive. Lab-on-a-chip (LOC) technology holds promise in addressing these challenges and advancing fundamental microbiological research while also aiding in the development of therapeutic strategies. This systematic review aims to evaluate the potential utility of LOC for AST of S. aureus. Materials and Methods: This study adhered to the PRISMA guidelines. Various databases, including SCOPUS, PubMed/MEDLINE, SCIELO, and LILACS, in addition to gray literature sources, were employed in the review process. Results: Sixteen studies were included in this systematic review. All these studies detailed the effectiveness, rapidity, and predictability of LOC systems for assessing S. aureus susceptibility to various antibiotics. When comparing the LOC approach to traditional manual methods, it was evident that LOC requires a minimal quantity of reagents. Furthermore, most studies reported that the entire LOC procedure took 10 min to 7 h, with results being equally accurate as those obtained through traditional AST protocols. Conclusions: The potential application of LOC for AST of S. aureus is emphasized by its ability to provide rapid access to minimum inhibitory concentration data, which can substantially aid in selecting the most suitable antibiotics and dosages for treating challenging infections caused by this microorganism. Moreover, the rapid AST facilitated by LOC holds promise for enhancing the appropriateness and efficacy of therapy in clinical settings.


Assuntos
Staphylococcus aureus Resistente à Meticilina , Infecções Estafilocócicas , Humanos , Staphylococcus aureus , Antibacterianos/farmacologia , Antibacterianos/uso terapêutico , Infecções Estafilocócicas/tratamento farmacológico , Dispositivos Lab-On-A-Chip
10.
Oral Dis ; 2023 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-37837245

RESUMO

OBJECTIVES: To assess the efficacy and adverse events linked to the utilization of fentanyl for perioperative pain management in dentistry. METHODS: This systematic review of randomized clinical trials (RCTs) adhered to the PRISMA guidelines and incorporated various databases. RESULTS: Eleven RCTs studying 674 patients were analyzed. Perioperative pain was predominantly evaluated in patients undergoing surgery for impacted molars, although some studies also included patients with other conditions such as oral submucous fibrosis, maxillary cancer, bony temporomandibular joint ankylosis, irreversible pulpitis, among others. Combined with dexmedetomidine, fentanyl produced enhanced analgesic effects. It demonstrated comparable efficacy when compared to nefopam and nalbuphine. Both intranasal and intravenous administration routes proved equally effective. In four RCTs, the transdermal fentanyl patch outperformed the control group, except in the clinical trial where it was compared to ropivacaine. The main adverse events associated with the use of fentanyl included nausea, vomiting, drowsiness, delirium, and respiratory depression; however, they were like those reported in the comparison groups. CONCLUSIONS: While fentanyl demonstrated satisfactory perioperative analgesic efficacy, there were other alternatives that displayed better or comparable outcomes. Due to the risks and potential for misuse of fentanyl, these alternatives must be considered although adverse events were also reported.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA