Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Minerva Stomatol ; 61(6): 273-82, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22669057

RESUMO

AIM: This study verified the effect of polymerizing cycles on the linear dimensional change, hardness and impact strength of denture acrylic resins. METHODS: One hundred and twenty samples (N.=10) each for the Classico and Vipi acrylic resins were made according to the manufacturers' instructions. The polymerization cycles were: 1- water bath at 74 ºC for 9 hr; 2- water bath at 74ºC for 8 hr and temperature increased to 100 ºC for 1 hr; 3- water bath at 74 ºC for 2 hr and temperature increased to 100 ºC for 1 hr; and 4- water bath at 120ºC and 60 pounds pressure for 1 hr. Samples were deflasked after flask cooling and submitted to finishing. Linear distances between referential points in the samples were measured at deflasking and after water storage for 7 and 30 days with a comparator microscope with an accuracy of 0.0005 mm. Knoop hardness test was accomplished in a durometer with a load of 25 gf for 10 sec and an average of three indentations was considered for the sample hardness. Impact strength (kgf/cm²) was measured by the Charpy system with load of 40 kpcm. Data were submitted to ANOVA and Tukey's test (5%). RESULTS: Dimensional changes in the A-B and A-C distances, hardness values and impact strength for Classico and Vipi resins were differently influenced by the polymerization cycles, when deflasking and water storage for 7 and 30 days were considered. CONCLUSION: Linear dimensional change, hardness and impact strength of denture acrylic resins were differently affected by the polymerization cycles.


Assuntos
Resinas Acrílicas , Análise do Estresse Dentário , Bases de Dentadura , Testes de Dureza , Teste de Materiais , Polimerização , Análise de Variância
2.
J Oral Rehabil ; 35(2): 123-7, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18197845

RESUMO

This study evaluated the precision of fit of implant frameworks cast in titanium (cp Ti) and palladium-silver alloy (Pd-Ag), made by the one-piece cast and laser welding techniques. From a metal matrix with five implants, 20 master casts were obtained, to which replicas of implants were incorporated. On these masters 10 frameworks were made for each type of material (cp Ti and Pd-Ag alloy). Half of these were made by the one-piece cast technique and the other half by the laser welding technique. The implant/prosthesis interface was analysed and measured in the vestibular and lingual regions of the central and distal implants with the help of a measuring microscope. The results indicated that in the central cylinders, the Tukey test (P<0.0005) showed a significant difference in the passive fit between the laser-welded frameworks (34.73 microm) and those one-piece cast frameworks (151.39 microm), and as regards materials, the palladium-silver alloy (66.30 microm) showed better results than the titanium (119.83 microm). In the distal cylinders there was no significant difference between the frameworks cast in titanium and palladium-silver by the one-piece technique. However, after laser welding, there was a significant difference for the frameworks cast in titanium (31.37 microm) and palladium-silver (106.59 microm).


Assuntos
Implantes Dentários , Materiais Dentários , Soldagem em Odontologia , Lasers , Ligas Dentárias , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Humanos , Teste de Materiais , Paládio , Prata , Titânio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA