Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Prosthodont Restor Dent ; 28(2): 65-74, 2020 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-32031764

RESUMO

This in vitro study evaluated the effect of the application and previous photoactivation of bonding adhesives in lithium disilicate ceramics. This was achieved by analyzing the bond strength of the cement-ceramic interface, nanohardness and elastic modulus of bonding adhesives and resin cements. The bonding adhesives used were Scotchbond Multi-Purpose (SBMP); Scotchbond Multi-Purpose light-cured (SBMP+LC); Single Bond 2 (SB2); Single Bond 2 light-cured (SB2+LC); Single Bond Universal (SBU) and Single Bond Universal light-cured (SBU+LC). After luting the ceramic in composite resin blocks, all specimens were subjected to 10,000 thermocycles. Sticks were obtained for the microtensile bonding strength test and the nanohardness and elastic modulus of the bonding adhesive and resin cements. Data were submitted to one-way ANOVA and Fishers tests (α =0.05). The results indicated that the bonding strength and mechanical properties were influenced by the interaction of the bonding adhesive and resin cement. For the mechanical properties analyzed, no statistically significant differences were observed between the groups. Single Bond Universal was the only system that was effective with or without previous light activation. For the other adhesive systems, Scotchbond Multi- Purpose and Single Bond 2, the previous light activation was necessary to optimize the bonding strength of the adhesive interface.


Assuntos
Colagem Dentária , Cerâmica , Coroas , Lâmpadas de Polimerização Dentária , Cimentos Dentários , Porcelana Dentária , Teste de Materiais , Cimentos de Resina , Resistência à Tração
2.
J Biomech ; 46(7): 1312-20, 2013 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-23518207

RESUMO

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária , Revestimento de Dentadura , Mandíbula/diagnóstico por imagem , Mandíbula/fisiopatologia , Estresse Mecânico , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
3.
J Dent Res ; 90(5): 613-8, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21335537

RESUMO

UNLABELLED: Lipopolysaccharide (LPS) may induce peri-implantitis and implant failure. However, the role of LPS in titanium (Ti) electrochemical behavior remains unknown. We hypothesized that LPS in saliva with different pHs affects Ti corrosion properties. Thirty-six Ti discs (15 mm × 3 mm) were divided into 12 groups according to saliva pH (3, 6.5, and 9) and Escherichia coli LPS concentration (0, 0.15, 15, and 150 µg/mL). Electrochemical tests, such as open circuit potential, potentiodynamic, and electrochemical impedance spectroscopy, were conducted in a controlled environment. Data were evaluated by Pearson correlation and regression analysis (α = 0.05). LPS and pH affected Ti corrosive behavior. In general, lower pH and higher LPS concentration accelerated Ti corrosion. In the control group, the increase of pH significantly reduced the corrosion rate and increased the capacitance of the double layer. In LPS groups, the decrease of pH significantly increased the corrosion rate of Ti. LPS negatively influenced Ti corrosion behavior. ABBREVIATIONS: C(dl), capacitance of double layer; E(corr), corrosion potential; EIS, electrochemical impedance spectroscopy; I(corr), corrosion current density; I(pass), passivation current density; LPS, lipopolysaccharide; OCP, open circuit potential; R(p), polarization resistance; Ti, titanium.


Assuntos
Materiais Revestidos Biocompatíveis/química , Lipopolissacarídeos/química , Titânio/química , Corrosão , Espectroscopia Dielétrica , Capacitância Elétrica , Impedância Elétrica , Eletroquímica , Escherichia coli , Concentração de Íons de Hidrogênio , Modelos Lineares , Teste de Materiais , Análise de Regressão , Saliva Artificial/química , Estatísticas não Paramétricas , Propriedades de Superfície
4.
J Oral Rehabil ; 35(10): 766-74, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18482352

RESUMO

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentulous mandible supporting an overdenture over two unsplinted implants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be concluded that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the mandibular overdenture.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Total , Revestimento de Dentadura , Análise do Estresse Dentário/métodos , Planejamento de Dentadura , Retenção de Dentadura/métodos , Humanos , Teste de Materiais/métodos , Modelos Anatômicos , Estresse Mecânico
6.
Revista da Faculdade de Odontología UFRGS;44(1): 43-46,
em Português | URUGUAIODONTO | ID: odn-17735
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA