Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
J Appl Biomech ; 40(4): 316-322, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38925535

RESUMO

Different forearm postures can modulate corticospinal excitability. However, there is no consensus on whether handedness plays a role in such a mechanism. This study investigated the effects of 3 forearm postures (pronation, neutral, and supination) on the corticospinal excitability of muscles from the dominant and nondominant upper limbs. Surface electromyography was recorded from the abductor digiti minimi, flexor pollicis brevis, and flexor carpi radialis from both sides of 12 right-handed volunteers. Transcranial magnetic stimulation pulses were applied to each muscle's hotspot in both cerebral hemispheres. Motor-evoked potential peak-to-peak amplitude and latency and resting motor threshold were measured. The data were evaluated by analysis of variance. The level of significance was set at 5%. The resting motor threshold was similar for the 3 muscles and both sides. Motor-evoked potential peak-to-peak amplitude from flexor pollicis brevis was lower during supination, and the dominant upper limb latency was longer. The flexor carpi radialis presented lower motor-evoked potential peak-to-peak amplitudes for neutral and shorter latencies during supination. Abductor digiti minimi seemed not to be affected by posture or side. Different muscles from dominant and nondominant sides may undergo corticospinal modulation, even distally localized from a particular joint and under rest.


Assuntos
Eletromiografia , Potencial Evocado Motor , Antebraço , Mãos , Músculo Esquelético , Postura , Tratos Piramidais , Estimulação Magnética Transcraniana , Humanos , Músculo Esquelético/fisiologia , Masculino , Antebraço/fisiologia , Postura/fisiologia , Potencial Evocado Motor/fisiologia , Mãos/fisiologia , Feminino , Tratos Piramidais/fisiologia , Adulto , Lateralidade Funcional/fisiologia , Adulto Jovem
2.
Sensors (Basel) ; 24(8)2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38676026

RESUMO

This work presents a novel multielectrode array (MEA) to quantitatively assess the dose enhancement factor (DEF) produced in a medium by embedded nanoparticles. The MEA has 16 nanocrystalline diamond electrodes (in a cell-culture well), and a single-crystal diamond divided into four quadrants for X-ray dosimetry. DEF was assessed in water solutions with up to a 1000 µg/mL concentration of silver, platinum, and gold nanoparticles. The X-ray detectors showed a linear response to radiation dose (r2 ≥ 0.9999). Overall, platinum and gold nanoparticles produced a dose enhancement in the medium (maximum of 1.9 and 3.1, respectively), while silver nanoparticles produced a shielding effect (maximum of 37%), lowering the dose in the medium. This work shows that the novel MEA can be a useful tool in the quantitative assessment of radiation dose enhancement due to nanoparticles. Together with its suitability for cells' exocytosis studies, it proves to be a highly versatile device for several applications.


Assuntos
Diamante , Eletrodos , Ouro , Nanopartículas Metálicas , Diamante/química , Nanopartículas Metálicas/química , Ouro/química , Prata/química , Platina/química , Doses de Radiação , Humanos , Raios X , Nanopartículas/química
3.
Heliyon ; 10(4): e25781, 2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38390158

RESUMO

Magnetic nanoparticles, such as magnetite (Fe3O4), exhibit superparamagnetic properties below 15 nm at room temperature. They are being explored for medical applications, and the coprecipitation technique is preferred for cost-effective production. This study investigates the impact of synthesis temperature on the nanoparticles' physicochemical characteristics. Two types of magnetic analysis were conducted. Samples T 40, T 50, and T 60 displayed superparamagnetic behavior, as evidenced by the magnetization curves. The experiments verified the development of magnetic nanoparticles with an average diameter of approximately dozens of nanometers, as determined by various measurement methods such as XDR, Raman, and TEM. Raman spectroscopy showed the characteristic bands of the magnetite phase at 319, 364, 499, and 680 cm-1. This was confirmed in the second analysis with the ZFC-FC curves, which showed that the samples' blocking temperatures were below ambient temperature. ZFC-FC curves revealed a similar magnetization of about 30 emu/g when applying a magnetic field of 5 kOe.

4.
Phys Eng Sci Med ; 46(2): 887-896, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-37166586

RESUMO

Navigated transcranial magnetic stimulation (nTMS) is a valuable tool for non-invasive brain stimulation. Currently, nTMS requires fixing of markers on the patient's head. Head marker displacements lead to changes in coil placement and brain stimulation inaccuracy. A markerless neuronavigation method is needed to increase the reliability of nTMS and simplify the nTMS protocol. In this study, we introduce and release MarLe, a Python markerless head tracker neuronavigation software for TMS. This novel software uses computer-vision techniques combined with low-cost cameras to estimate the head pose for neuronavigation. A coregistration algorithm, based on a closed-form solution, was designed to track the patient's head and the TMS coil referenced to the individual's brain image. We show that MarLe can estimate head pose based on real-time video processing. An intuitive pipeline was developed to connect the MarLe and nTMS neuronavigation software. MarLe achieved acceptable accuracy and stability in a mockup nTMS experiment. MarLe allows real-time tracking of the patient's head without any markers. The combination of face detection and a coregistration algorithm can overcome nTMS head marker displacement concerns. MarLe can improve reliability, simplify, and reduce the protocol time of brain intervention techniques such as nTMS.


Assuntos
Neoplasias Encefálicas , Estimulação Magnética Transcraniana , Humanos , Estimulação Magnética Transcraniana/métodos , Reprodutibilidade dos Testes , Mapeamento Encefálico/métodos , Encéfalo
5.
Nanomaterials (Basel) ; 13(3)2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36770395

RESUMO

The development of nanomaterials has drawn considerable attention in nanomedicine to advance cancer diagnosis and treatment over the last decades. Gold nanorods (GNRs) and magnetic nanoparticles (MNPs) have been known as commonly used nanostructures in biomedical applications due to their attractive optical properties and superparamagnetic (SP) behaviors, respectively. In this study, we proposed a simple combination of plasmonic and SP properties into hybrid NPs of citrate-coated manganese ferrite (Ci-MnFe2O4) and cetyltrimethylammonium bromide-coated GNRs (CTAB-GNRs). In this regard, two different samples were prepared: the first was composed of Ci-MnFe2O4 (0.4 wt%), and the second contained hybrid NPs of Ci-MnFe2O4 (0.4 wt%) and CTAB-GNRs (0.04 wt%). Characterization measurements such as UV-Visible spectroscopy and transmission electron microscopy (TEM) revealed electrostatic interactions caused by the opposing surface charges of hybrid NPs, which resulted in the formation of small nanoclusters. The performance of the two samples was investigated using magneto-motive ultrasound imaging (MMUS). The sample containing Ci-MnFe2O4_CTAB-GNRs demonstrated a displacement nearly two-fold greater than just using Ci-MnFe2O4; therefore, enhancing MMUS image contrast. Furthermore, the preliminary potential of these hybrid NPs was also examined in magnetic hyperthermia (MH) and photoacoustic imaging (PAI) modalities. Lastly, these hybrid NPs demonstrated high stability and an absence of aggregation in water and phosphate buffer solution (PBS) medium. Thus, Ci-MnFe2O4_CTAB-GNRs hybrid NPs can be considered as a potential contrast agent in MMUS and PAI and a heat generator in MH.

6.
Molecules ; 27(20)2022 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-36296641

RESUMO

The study of new materials for radiation dosimetry is important to improve the present state of the art and to help in cases of accidents for retrospective dosimetry. Sulfites are compounds that contain a sulfur ion, widely used in the food industry. Due to the significant application of these compounds, sulfites are interesting candidates for accidental dosimetry, as fortuitous radiation detectors. The presence of the SO3- anion enables its detection by electron spin resonance (ESR) spectroscopy. The Dose-Response behavior, signal stability and other spectral features were investigated for sodium sulfite, sodium bisulfite, sodium metabisulfite and potassium metabisulfite, all in crystalline forms. The ESR spectrum of salts presented stability and proportional response with dose, presenting potential for dosimetry applications.


Assuntos
Sais , Sulfitos , Espectroscopia de Ressonância de Spin Eletrônica , Estudos Retrospectivos , Sulfitos/química , Radiometria , Ânions , Enxofre
7.
Pharmaceutics ; 14(9)2022 Sep 08.
Artigo em Inglês | MEDLINE | ID: mdl-36145654

RESUMO

Since magnetic nanoparticles (MNPs) have been used as multifunctional probes to diagnose and treat liver diseases in recent years, this study aimed to assess how the condition of cirrhosis-associated hepatocarcinogenesis alters the biodistribution of hepatic MNPs. Using a real-time image acquisition approach, the distribution profile of MNPs after intravenous administration was monitored using an AC biosusceptometry (ACB) assay. We assessed the biodistribution profile based on the ACB images obtained through selected regions of interest (ROIs) in the heart and liver position according to the anatomical references previously selected. The signals obtained allowed for the quantification of pharmacokinetic parameters, indicating that the uptake of hepatic MNPs is compromised during liver cirrhosis, since scar tissue reduces blood flow through the liver and slows its processing function. Since liver monocytes/macrophages remained constant during the cirrhotic stage, the increased intrahepatic vascular resistance associated with impaired hepatic sinusoidal circulation was considered the potential reason for the change in the distribution of MNPs.

8.
Gels ; 8(9)2022 Sep 13.
Artigo em Inglês | MEDLINE | ID: mdl-36135294

RESUMO

Craniospinal irradiation (CSI) is a complex radiation technique employed to treat patients with primitive neuroectodermal tumors such as medulloblastoma or germinative brain tumors with the risk of leptomeningeal spread. In adults, this technique poses a technically challenging planning process because of the complex shape and length of the target volume. Thus, it requires multiple fields and different isocenters to guarantee the primary-tumor dose delivery. Recently, some authors have proposed the use IMRT technique for this planning with the possibility of overlapping adjacent fields. The high-dose delivery complexity demands three-dimensional dosimetry (3DD) to verify this irradiation procedure and motivated this study. We used an optical CT and a radiochromic Fricke-xylenol-orange gel with the addition of formaldehyde (FXO-f) to evaluate the doses delivered at the field junction region of this treatment. We found 96.91% as the mean passing rate using the gamma analysis with 3%/2 mm criteria at the junction region. However, the concentration of fail points in a determined region called attention to this evaluation, indicating the advantages of employing a 3DD technique in complex dose-distribution verifications.

9.
Acta Cir Bras ; 37(5): e370504, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35976341

RESUMO

PURPOSE: To study the influence of silver nanoparticles (AgNP) on tissue reaction when incorporated into a polymeric matrix of polyacrylic acid-based (Carbopol®) gel as a proposal for a new low-cost type of biomaterial that is simple to manufacture for use as an antimicrobial and antioxidative dressing. METHODS: In-vivo tests of implantation in the subcutaneous tissue of the back of rats were performed using polyethylene tubes in three situations: empty, only the gel, and gel incorporated with AgNP. Then, the tissue reaction was studied by counting inflammatory cells. Additionally, in-vitro tests of the antioxidative and antimicrobial activity of AgNP were performed. The radical 2,2 diphenyl-1 picrylhydrazyl (DPPH) was used to test the antioxidative activity of AgNP using electron spin resonance. The antimicrobial activity of AgNP was determined by minimum inhibitory concentration against the microorganisms: Staphylococcus aureus, Pseudomonas aeruginosa, and Escherichia coli. RESULTS: The results indicated that AgNP presents antioxidative activity and was able to inhibit the growth of the microorganisms tested. The addition of AgNP in Carbopol® did not alter the tissue inflammatory response (p>0.05, Kruskal-Wallis's test). CONCLUSIONS: The new biomaterial is promising for future use as a dressing for its beneficial properties for regenerative processes.


Assuntos
Anti-Infecciosos , Nanopartículas Metálicas , Resinas Acrílicas , Animais , Antibacterianos/farmacologia , Anti-Infecciosos/farmacologia , Materiais Biocompatíveis/farmacologia , Escherichia coli , Ratos , Prata/farmacologia
10.
Materials (Basel) ; 15(6)2022 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-35329574

RESUMO

Once administered in an organism, the physiological parameters of magnetic nanoparticles (MNPs) must be addressed, as well as their possible interactions and retention and elimination profiles. Alternating current biosusceptometry (ACB) is a biomagnetic detection system used to detect and quantify MNPs. The aims of this study were to evaluate the biodistribution and clearance of MNPs profiles through long-time in vivo analysis and determine the elimination time carried out by the association between the ACB system and MnFe2O4 nanoparticles. The liver, lung, spleen, kidneys, and heart and a blood sample were collected for biodistribution analysis and, for elimination analysis, and over 60 days. During the period analyzed, the animal's feces were also collectedd. It was possible to notice a higher uptake by the liver and the spleen due to their characteristics of retention and uptake. In 60 days, we observed an absence of MNPs in the spleen and a significant decay in the liver. We also determined the MNPs' half-life through the liver and the spleen elimination. The data indicated a concentration decay profile over the 60 days, which suggests that, in addition to elimination via feces, there is an endogenous mechanism of metabolization or possible agglomeration of MNPs, resulting in loss of ACB signal intensity.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA