Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Acta Odontol Latinoam ; 36(1): 58-65, 2023 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-37315327

RESUMO

Color stability is among the most frequent causes of restoration failures, and influences surface properties. Aim: The aim of this study was to investigate the influence of pigment solutions on low-shrinkage and conventional composites regarding changes in the physical properties of composite surfaces. Materials and Method: Specimens of four composites (Filtek Z350 XT, Point 4, N'Durance and Venus Diamond) were randomly distributed into three groups to be submitted to each of three pigment solutions (red wine, tomato sauce and coffee) in fifteen-minute daily cycles, for twenty-eight days. There were 12 groups altogether (n = 10). Color, surface roughness and hardness tests were performed. Statistical analysis includedAnalysis of variance (ANOVA) and Tukey's significance test (a = 0.05). Results: Color changes caused by the solutions did not differ significantly among Filtek Z350 XT, Venus Diamond and N'Durance. Hardness decreased significantly in Filtek Z350 XT and Venus Diamond after chemical challenge with each solution. For the composite independent factor, roughness was highest in Venus Diamond, followed by Filtek Z350 XT, Point 4 and N'Durance. Conclusions: Treatment with different pigment solutions (red wine, tomato sauce or coffee) increased stainability and decreased hardness of both low-shrinkage and conventional composites, while roughness was unaffected.


A estabilidade de cor está entre as causas mais frequentes de falhas de restauragoes, que também influenciam suas propriedades superficiais. Objetivo: O objetivo do presente estudo foi investigar a influencia de solugoes de pigmentos em compósitos convencionais e de baixa retragao, bem como alteragoes naspropriedades físicas da superficie dos compósitos. Materiais eMétodo: Amostras de cada compósito (Filtek Z350XT, Point 4, N'Durance e Venus Diamond) foram distribuidas aleatoriamente em grupos submetidos a cada solugao pigmentante (vinho tinto, molho de tomate e café) em ciclos diários de quinze minutos, durante vinte e oito dias. Assim, totalizando 12 grupos (n = 10). Foram realizados testes de cor, rugosidade superficial e dureza. A Análise Estatistica foi realizada usando Análise de variáncia (ANOVA) e o teste de significáncia de Tukey (a = 0.05). Resultados: As alteragoes de cor desencadeadas pelas solugoes investigadas nao mostraram diferenga estatisticamente significativa entre os compósitos Filtek Z350 XT, Venus Diamond e N'Durance. Os valores de dureza registrados para Filtek Z350XT e Venus Diamond diminuiram significativamente após o desafio químico com cada uma das solugoes pigmentantes. Para o fator independente compósito, Venus Diamond registrou a maior rugosidade; foi seguido por Filtek Z350XT, Point 4 e N'Durance. Conclusoes: Os tratamentos das amostras com diferentes solugoes pigmentantes (vinho tinto, molho de tomate e café) aumentaram a manchabilidade dos compósitos convencionais e de baixa retragao e diminuiram sua dureza, embora nao tenham afetado a rugosidade dos compósitos.


Assuntos
Café , Diamante , Dureza , Propriedades de Superfície
2.
Acta odontol. latinoam ; 36(1): 58-65, Apr. 2023. tab
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1447077

RESUMO

ABSTRACT Color stability is among the most frequent causes of restoration failures, and influences surface properties. Aim: The aim of this study was to investigate the influence of pigment solutions on low-shrinkage and conventional composites regarding changes in the physical properties of composite surfaces. Materials and Method: Specimens of four composites (Filtek Z350 XT, Point 4, N'Durance and Venus Diamond) were randomly distributed into three groups to be submitted to each of three pigment solutions (red wine, tomato sauce and coffee) in fifteen-minute daily cycles, for twenty-eight days. There were 12 groups altogether (n = 10). Color, surface roughness and hardness tests were performed. Statistical analysis includedAnalysis of variance (ANOVA) and Tukey's significance test (a = 0.05). Results: Color changes caused by the solutions did not differ significantly among Filtek Z350 XT, Venus Diamond and N'Durance. Hardness decreased significantly in Filtek Z350 XT and Venus Diamond after chemical challenge with each solution. For the composite independent factor, roughness was highest in Venus Diamond, followed by Filtek Z350 XT, Point 4 and N'Durance. Conclusions: Treatment with different pigment solutions (red wine, tomato sauce or coffee) increased stainability and decreased hardness of both low-shrinkage and conventional composites, while roughness was unaffected.


RESUMO A estabilidade de cor está entre as causas mais frequentes de falhas de restauragoes, que também influenciam suas propriedades superficiais. Objetivo: O objetivo do presente estudo foi investigar a influencia de solugoes de pigmentos em compósitos convencionais e de baixa retragao, bem como alteragoes naspropriedades físicas da superficie dos compósitos. Materiais eMétodo: Amostras de cada compósito (Filtek Z350XT, Point 4, N'Durance e Venus Diamond) foram distribuidas aleatoriamente em grupos submetidos a cada solugao pigmentante (vinho tinto, molho de tomate e café) em ciclos diários de quinze minutos, durante vinte e oito dias. Assim, totalizando 12 grupos (n = 10). Foram realizados testes de cor, rugosidade superficial e dureza. A Análise Estatistica foi realizada usando Análise de variáncia (ANOVA) e o teste de significáncia de Tukey (a = 0.05). Resultados: As alteragoes de cor desencadeadas pelas solugoes investigadas nao mostraram diferenga estatisticamente significativa entre os compósitos Filtek Z350 XT, Venus Diamond e N'Durance. Os valores de dureza registrados para Filtek Z350XT e Venus Diamond diminuiram significativamente após o desafio químico com cada uma das solugoes pigmentantes. Para o fator independente compósito, Venus Diamond registrou a maior rugosidade; foi seguido por Filtek Z350XT, Point 4 e N'Durance. Conclusoes: Os tratamentos das amostras com diferentes solugoes pigmentantes (vinho tinto, molho de tomate e café) aumentaram a manchabilidade dos compósitos convencionais e de baixa retragao e diminuiram sua dureza, embora nao tenham afetado a rugosidade dos compósitos.

3.
Acta Odontol Latinoam ; 34(3): 226-232, 2021 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-35088809

RESUMO

The aim of this study was to compare the microshear bond strength of different resin cements to CAD/CAM-created lithium disilicate ceramics after 24 hours and after 1 year (10,000 thermocycles). Forty (40) ceramic bars were subjected to pretreatment comprising airborne abrasion with aluminum oxide particles, etching with 10% hydrofluoric acid and Monobond N application. Bars were divided into 4 groups (n = 10), based on cement type: light-cured Variolink Esthetic LC (VLC) and dual-cured Variolink N (VN) at two different times: after 24 hours and after 1 year. Silicone molds were used to prepare cement cylinders on a ceramic surface. The set was stored in distilled water at 37ºC, for 24 hours or subjected to 10,000 thermocycles. The molds were removed and microshear bond strength was tested. Data were submitted to two-way analysis of variance and Tukey's test (α = 0.05). Based on the comparison between cement values at different aging times (p = 0.035), VN after 24 hours (27.10 ± 0.92) and after 1 year (20.62 ± 1.25) presented significantly higher values than VLC after 24 hours (14.79 ± 0.76) and after 1 year (6.61 ± 0.81). Bond strength recorded for both cements after 24 hours (VN: 27.10 ± 0.92 and VLC: 14.79 ± 0.76) was significantly higher than the one recorded after 1 year (VN: 20.62 ± 1.25 and VLC: 6.61 ± 0.81). The thermocycling reduced the values observed for both investigated cements; bond strength was greater for dual-cure resin cement than for light-cured resin cement.


O objetivo nesse estudo foi comparar a resistência de união de diferentes cimentos resinosos à cerâmica de dissilicato de lítio processada por CAD/CAM após 24 horas e após 1 ano (10.000 termociclos). Foram utilizadas 40 barras cerâmicas com tratamento prévio por jateamento com óxido de alumínio, condicionamento com ácido fluorídrico 10% e aplicação do Monobond N. As barras foram divididas em 4 grupos (n=10) de acordo com o tipo de cimento: fotopolimerizável Variolink Esthetic LC (VLC) e dual Variolink N (VN) em diferentes tempos: após 24 horas e 1 ano. Matrizes de silicone foram usadas para preparar cilindros de cimento na superfície cerâmica. O conjunto foi armazenado em água destilada a 37ºC por 24 horas ou submetidos protocolo de termociclagem com 10.000 ciclos. As matrizes foram removidas e o teste de microcisalhamento realizado. Os dados foram avaliados por análise de variância a dois fatores e teste de Tukey (α=0,05). Ao comparar os valores dos cimentos em diferentes tempos de envelhecimento (p=0,035), observou-se que VN, após 24 horas (27,10 ± 0,92) e 1 ano (20,62 ± 1,25) apresentou valores significativamente superior a VLC após 24 horas (14,79 ± 0,76) e 1 ano (6,61 ± 0,81). A resistência para ambos os cimentos após 24 horas (VN: 27,10 ± 0,92 e VLC: 14,79 ± 0,76) foi significativamente superior que 1 ano (VN: 20,62 ± 1,25 e VLC: 6,61 ± 0,81). A termociclagem promoveu diminuição nos valores de ambos os cimentos estudados e o cimento resinoso dual mostrou maior resistência de união que o cimento resinoso fotopolimerizável.


Assuntos
Colagem Dentária , Cimentos de Resina , Cerâmica , Porcelana Dentária , Análise do Estresse Dentário , Teste de Materiais , Propriedades de Superfície
4.
Acta odontol. latinoam ; 34(3): 226-232, 2021. graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1383409

RESUMO

ABSTRACT The aim of this study was to compare the microshear bond strength of different resin cements to CAD/CAM-created lithium disilicate ceramics after 24 hours and after 1 year (10,000 thermocycles). Forty (40) ceramic bars were subjected to pretreatment comprising airborne abrasion with aluminum oxide particles, etching with 10% hydrofluoric acid and Monobond N application. Bars were divided into 4 groups (n = 10), based on cement type: light-cured Variolink Esthetic LC (VLC) and dual-cured Variolink N (VN) at two different times: after 24 hours and after 1 year. Silicone molds were used to prepare cement cylinders on a ceramic surface. The set was stored in distilled water at 37ºC, for 24 hours or subjected to 10,000 thermocycles. The molds were removed and microshear bond strength was tested. Data were submitted to two-way analysis of variance and Tukey's test (α = 0.05). Based on the comparison between cement values at different aging times (p = 0.035), VN after 24 hours (27.10 ± 0.92) and after 1 year (20.62 ± 1.25) presented significantly higher values than VLC after 24 hours (14.79 ± 0.76) and after 1 year (6.61 ± 0.81). Bond strength recorded for both cements after 24 hours (VN: 27.10 ± 0.92 and VLC: 14.79 ± 0.76) was significantly higher than the one recorded after 1 year (VN: 20.62 ± 1.25 and VLC: 6.61 ± 0.81). The thermocycling reduced the values observed for both investigated cements; bond strength was greater for dual-cure resin cement than for light-cured resin cement.


RESUMO O objetivo nesse estudo foi comparar a resistência de união de diferentes cimentos resinosos à cerâmica de dissilicato de lítio processada por CAD/CAM após 24 horas e após 1 ano (10.000 termociclos). Foram utilizadas 40 barras cerâmicas com tratamento prévio por jateamento com óxido de alumínio, condicionamento com ácido fluorídrico 10% e aplicação do Monobond N. As barras foram divididas em 4 grupos (n=10) de acordo com o tipo de cimento: fotopolimerizável Variolink Esthetic LC (VLC) e dual Variolink N (VN) em diferentes tempos: após 24 horas e 1 ano. Matrizes de silicone foram usadas para preparar cilindros de cimento na superfície cerâmica. O conjunto foi armazenado em água destilada a 37ºC por 24 horas ou submetidos protocolo de termociclagem com 10.000 ciclos. As matrizes foram removidas e o teste de microcisalhamento realizado. Os dados foram avaliados por análise de variância a dois fatores e teste de Tukey (α=0,05). Ao comparar os valores dos cimentos em diferentes tempos de envelhecimento (p=0,035), observou-se que VN, após 24 horas (27,10 ± 0,92) e 1 ano (20,62 ± 1,25) apresentou valores significativamente superior a VLC após 24 horas (14,79 ± 0,76) e 1 ano (6,61 ± 0,81). A resistência para ambos os cimentos após 24 horas (VN: 27,10 ± 0,92 e VLC: 14,79 ± 0,76) foi significativamente superior que 1 ano (VN: 20,62 ± 1,25 e VLC: 6,61 ± 0,81). A termociclagem promoveu diminuição nos valores de ambos os cimentos estudados e o cimento resinoso dual mostrou maior resistência de união que o cimento resinoso fotopolimerizável.

5.
Acta Odontol Latinoam ; 33(2): 98, 2020 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-32920611

RESUMO

The aim of the current study was to compare the effect of two lithium disilicate ceramic processing techniques (pressing and CAD/CAM) on the degree of conversion of resin cement when it is photoactivated and the microshear bond strength of resin cement to ceramics. Two ceramic discs were manufactured: one by the Press technique and another by CAD/CAM technique. Five Variolink Veneer resin cement samples were photoactivated through each ceramic disc and subjected to attenuated total reflectance Fourier transform infrared spectroscopy to evaluate their degree of conversion. To evaluate microshear bond strength, 20 ceramic bars were prepared: 10 using the Press technique and 10 using the CAD/CAM technique. The bars were air abraded with 50-µm Al2O3 particles, treated with 10% hydrofluoric acid for 20 s and subjected to RelyX Ceramic Primer application. Adper Scotchbond Multi-Purpose Adhesive was applied to the bars and cured for 10 s. Two 1-mm-height plastic tubes were placed on each bar and filled with Variolink Veneer resin cement. Each cylinder was cured for 20 s. Then the plastic tubes were removed and the microshear bond strength of each cylinder was tested. Data for degree of conversion (%) and microshear bond strength (MPa) were subjected to Student's t-test (α = 0.05). Both degree of conversion of resin cement photoactivated through ceramic and microshear bond strength of resin cement to ceramic were statistically higher in the group in which ceramic was prepared by CAD/CAM technique (44.74% and 22.18 MPa) than in the group in which the ceramic was prepared by the Press technique (25.71% and 19.83 MPa). The lithium disilicate ceramic processing techniques affected the degree of conversion of resin cement when it is photoactivated through the ceramics and the microshear bond strength of resin cement to ceramics.


O objetivo do presente estudo foi comparar o efeito de duas técnicas de processamento da cerâmica de dissilicato de lítio (prensada e CAD/CAM) no grau de conversão do cimento resinoso quando fotoativado e na resistência de união ao microcisalhamento do cimento resinoso às cerâmicas. Foram fabricados dois discos de cerâmica: um pela técnica prensada e outro pela técnica CAD/CAM. Cinco amostras de cimento resinoso Variolink Veneer foram fotoativadas através de cada disco cerâmico e submetidas à espectroscopia no infravermelho por transformada de Fourier com reflectância total para avaliar seu grau de conversão. Para avaliar a resistência de união ao microcisalhamento, foram preparadas 20 barras de cerâmicas: 10 utilizando a técnica prensada e 10 utilizando a técnica CAD/CAM. As barras foram tratadas com partículas de Al2O3 (50 µm), com ácido fluorídrico a 10% por 20 s e submetidas à aplicação do RelyX Ceramic Primer. Em seguida, o adesivo multiuso Adper Scotchbond foi aplicado nas barras e fotoativado por 10 s. Dois tubos de plástico de 1 mm de comprimento foram colocados em cada barra e preenchidos com cimento resinoso Variolink Veneer. Cada cilindro foi fotoativado por 20 s. Os tubos de plástico foram removidos e a resistência de união ao microcisalhamento de cada cilindro foi testada. Os dados de grau de conversão (%) e resistência de união ao microcisalhamento (MPa) foram submetidos ao teste t de Student (α = 0,05). Tanto o grau de conversão do cimento resinoso fotoativado através da cerâmica quanto a resistência de união do cimento resinoso à cerâmica foram estatisticamente maiores no grupo em que a cerâmica foi confeccionada pela técnica CAD/CAM (44,74% e 22,18 MPa) do que no grupo em que a cerâmica foi confeccionada pela técnica prensada (25,71% e 19,83 MPa). As técnicas de processamento de cerâmica dissilicada de lítio afetaram o grau de conversão do cimento resinoso quando fotoativado através das cerâmicas e a resistência de união do microcisalhamento do cimento resinoso às cerâmicas.


Assuntos
Cerâmica/química , Colagem Dentária , Porcelana Dentária/química , Cimentos de Resina/química , Humanos , Teste de Materiais , Propriedades de Superfície
6.
Acta odontol. latinoam ; 33(2): 98-103, Sept. 2020. graf
Artigo em Inglês | LILACS | ID: biblio-1130739

RESUMO

ABSTRACT The aim of the current study was to compare the effect of two lithium disilicate ceramic processing techniques (pressing and CAD/CAM) on the degree of conversion of resin cement when it is photoactivated and the microshear bond strength of resin cement to ceramics. Two ceramic discs were manufactured: one by the Press technique and another by CAD/CAM technique. Five Variolink Veneer resin cement samples were photoactivated through each ceramic disc and subjected to attenuated total reflectance Fourier transform infrared spectroscopy to evaluate their degree of conversion. To evaluate microshear bond strength, 20 ceramic bars were prepared: 10 using the Press technique and 10 using the CAD/CAM technique. The bars were air abraded with 50-μm Al2O3 particles, treated with 10% hydrofluoric acid for 20 s and subjected to RelyX Ceramic Primer application. Adper Scotchbond Multi-Purpose Adhesive was applied to the bars and cured for 10 s. Two 1-mm-height plastic tubes were placed on each bar and filled with Variolink Veneer resin cement. Each cylinder was cured for 20 s. Then the plastic tubes were removed and the microshear bond strength of each cylinder was tested. Data for degree of conversion (%) and microshear bond strength (MPa) were subjected to Student's t-test (α = 0.05). Both degree of conversion of resin cement photoactivated through ceramic and microshear bond strength of resin cement to ceramic were statistically higher in the group in which ceramic was prepared by CAD/CAM technique (44.74% and 22.18 MPa) than in the group in which the ceramic was prepared by the Press technique (25.71% and 19.83 MPa). The lithium disilicate ceramic processing techniques affected the degree of conversion of resin cement when it is photoactivated through the ceramics and the microshear bond strength of resin cement to ceramics.


RESUMO O objetivo do presente estudo foi comparar o efeito de duas técnicas de processamento da cerâmica de dissilicato de lítio (prensada e CAD/CAM) no grau de conversão do cimento resinoso quando fotoativado e na resistência de união ao microcisalhamento do cimento resinoso às cerâmicas. Foram fabricados dois discos de cerâmica: um pela técnica prensada e outro pela técnica CAD/CAM. Cinco amostras de cimento resinoso Variolink Veneer foram fotoativadas através de cada disco cerâmico e submetidas à espectroscopia no infravermelho por transformada de Fourier com reflectância total para avaliar seu grau de conversão. Para avaliar a resistência de união ao microcisalhamento, foram preparadas 20 barras de cerâmicas: 10 utilizando a técnica prensada e 10 utilizando a técnica CAD/CAM. As barras foram tratadas com partículas de Al2O3 (50 μm), com ácido fluorídrico a 10% por 20 s e submetidas à aplicação do RelyX Ceramic Primer. Em seguida, o adesivo multiuso Adper Scotchbond foi aplicado nas barras e fotoativado por 10 s. Dois tubos de plástico de 1 mm de comprimento foram colocados em cada barra e preenchidos com cimento resinoso Variolink Veneer. Cada cilindro foi fotoativado por 20 s. Os tubos de plástico foram removidos e a resistência de união ao microcisalhamento de cada cilindro foi testada. Os dados de grau de conversão (%) e resistência de união ao microcisalhamento (MPa) foram submetidos ao teste t de Student (α = 0,05). Tanto o grau de conversão do cimento resinoso fotoativado através da cerâmica quanto a resistência de união do cimento resinoso à cerâmica foram estatisticamente maiores no grupo em que a cerâmica foi confeccionada pela técnica CAD/CAM (44,74% e 22,18 MPa) do que no grupo em que a cerâmica foi confeccionada pela técnica prensada (25,71% e 19,83 MPa). As técnicas de processamento de cerâmica dissilicada de lítio afetaram o grau de conversão do cimento resinoso quando fotoativado através das cerâmicas e a resistência de união do microcisalhamento do cimento resinoso às cerâmicas.


Assuntos
Humanos , Cerâmica/química , Colagem Dentária , Cimentos de Resina/química , Porcelana Dentária/química , Propriedades de Superfície , Teste de Materiais
7.
Minerva Stomatol ; 69(3): 153-158, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31633319

RESUMO

BACKGROUND: The objective was to examine the microshear bond strength values of different dual resin cements to computer-aided design (CAD)/computer-aided manufacturing (CAM)-created ceramics containing lithium disilicate, which underwent different surface treatments. METHODS: Two dual resin cements (RelyX ARC and RelyX Ultimate) and three surface treatments of lithium disilicate ceramic blocks (Ceramic Primer (CP; containing silane) plus Adper Scotchbond Multipurpose (ASM) adhesive; CP plus Single Bond Universal (SBU) adhesive; and SBU adhesive alone) were tested. The SBU adhesive includes silane in its formulation. Each sample underwent a microshear test and bond strength values were subjected to analysis of variance (ANOVA) followed by Tukey's test (α=0.05). Fracture patterns were also observed with light microscopy. RESULTS: RelyX ARC treated with CP+ASM or CP+SBU presented resistance values that were significantly higher than the same treatments for RelyX Ultimate. Conversely, for the blocks treated with SBU alone, the mean resistance value for RelyX Ultimate was higher than that of RelyX ARC. Regarding the different types of treatment for each resin, the mean resistance value of RelyX ARC treated with CP+ASM was significantly highest, followed by treatment with CP+SBU and SBU treatment alone. Meanwhile, RelyX Ultimate treated with CP+ASM or CP+SBU presented resistance values that were significantly higher than SBU treatment alone. In all of the groups, an adhesive fracture pattern was predominantly observed. CONCLUSIONS: The present results indicate that silanization is important for ASM and SBU adhesives to be effective.


Assuntos
Colagem Dentária , Cimentos de Resina , Cerâmica , Desenho Assistido por Computador , Cimentos Dentários , Porcelana Dentária , Teste de Materiais , Propriedades de Superfície
8.
Minerva Stomatol ; 68(5): 259-264, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31822050

RESUMO

BACKGROUND: To evaluate the effects of adhesive systems and primer systems on microshear bond strength of chemically activated resin cemented to Co-Cr cast dental alloy. METHODS: Seventy-two rectangular blocks of Co-Cr metal alloy were manufactured and air-abraded with 50-µm Al2O3 particles. Metal primers (alloy primer [AP] or Clearfil ceramic primer [CP]) and adhesives (Adper Scotchbond Multi-Purpose Adhesive activated by Adper Scotchbond Multi-Purpose Adhesive Catalyst [SASC], or Primer & Bond 2.1 activated by Self Cure Activator [PBCA]) were applied and subsequently divided into six groups (SASC; AP+SASC; CP+SASC; PBCA; AP+PBCA; CP+PBCA; N.=12). Then, resin cement (Enforce) was applied. Data about microshear bond strength values were statistically evaluated by analysis of variance and Tukey's test. RESULTS: The bond strength was lower (P<0.001) in groups with adhesive system alone (SASC and PBCA) compared with groups with addition of primers alloy primer (AP+SASC and AP+PBCA) and ceramic primer (CP+SASC and CP+PBCA). CONCLUSIONS: The application of primers improves the bond strength of the cement resin to the Co-Cr metal alloy.


Assuntos
Colagem Dentária , Cimentos de Resina , Ligas , Análise do Estresse Dentário , Teste de Materiais , Metacrilatos , Resistência ao Cisalhamento , Propriedades de Superfície
9.
Am J Dent ; 32(5): 235-239, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31675191

RESUMO

PURPOSE: To evaluate the effect of whitening mouthrinses on sorption (SP) and solubility (SL), percentage of microhardness change (%M), loss of surface (LS), and color change (ΔE) in bulk-fill composites when compared with conventional composites. METHODS: Three bulk-fill composites, Surefil SDR (SF), Filtek Bulk-Fill (BF), and Filtek Bulk-Fill Flow (BFF), and one conventional resin, Filtek Z350 (FZ), were selected. Eighteen samples of each composite were subdivided into three groups based on the type of treatment: Listerine Whitening mouthrinse (LW), Colgate Plax Whitening mouthrinse (CP), and distilled water (DW; control). The samples were prepared according to ISO 4049:2009. Color, roughness, and microhardness were evaluated before and after treatment, while SP and SL values were measured after treatment. The surface morphology of the specimen was examined using scanning electron microscopy. Data were analyzed using two-way ANOVA and Tukey's test. RESULTS: FZ presented significantly lower ΔE when immersed in DW. Additionally, LS was lowest in FZ when compared with the other resins. SF and BFF demonstrated high %M. SL was significantly higher in SF, whereas SP was lowest in BFF after CP treatment. No significant alterations in surface morphology were noted in the BF composites. The BF composites showed a decrease in their properties after immersion in the two types of mouthrinses or in DW, without alterations in the surface morphology. CLINICAL SIGNIFICANCE: Flowable bulk-fill composites showed the greatest changes in their properties when exposed to different mouthrinses or water. Thus, they should be used with caution in areas that will stay exposed to the oral cavity.


Assuntos
Resinas Compostas , Teste de Materiais , Solubilidade
10.
Braz Dent J ; 30(5): 453-458, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31596329

RESUMO

The aim of this study was to analyze the effects of MTA on the structure and enzymatic activity of sPLA2 in order to provide subsidies for improvement in the formulation of the product. MTA powder was incubated for 60 min in the presence of sPLA2 and was analyzed by chromatography, electrospray mass (ESI-MS) and small-angle X-ray scattering (SAXS). It was find that the elution profile, retention time, and fragmentation of sPLA2 were altered after treatment with MTA. Calcium was the MTA component that most amplified the inflammatory signal. Significant interactions were found between MTA and sPLA2, which could aid in our understanding of the mechanisms of action of MTA during the inflammatory process and it may facilitate the structural modification of MTA, thereby improving its biological safety and consequently the rate of the treatment success.


Assuntos
Materiais Restauradores do Canal Radicular , Compostos de Alumínio , Compostos de Cálcio , Combinação de Medicamentos , Óxidos , Espalhamento a Baixo Ângulo , Silicatos , Difração de Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA