Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Acta Ortop Mex ; 37(3): 177-182, 2023.
Artigo em Espanhol | MEDLINE | ID: mdl-38052440

RESUMO

INTRODUCTION: aneurysms are focal and permanent dilations of an artery; in pseudoaneurysms, the normal layers of the blood vessel are replaced by fibrous tissue. Due to their low incidence, as well as the diagnostic and therapeutic challenge they represent; our objective is to present the clinical case of a pseudoaneurysm of a digital artery of the hand and to carry out a systematic review of this pathology. MATERIAL AND METHODS: literature search in Medline, using the terms "digital artery" and "aneurysm." Studies of vascular dilation pathology affecting the hand and fingers were incorporated. Studies with pathology of proximal involvement of the hand were excluded. CASE PRESENTATION: a 79-year-old female patient who, after a sharp force trauma to the fifth finger of the left hand, develops a rapidly growing necrotic tumor. She had ultrasound and angiography that suggested hematoma. Surgical management was decided, during which it was observed that the tumor involved ulnar collateral digital artery of the fifth finger. The lesion and the arterial segment involved were resected. Post-surgical course without complications. The histopathological diagnosis of pseudoaneurysm of the lesion was confirmed. DISCUSSION: traumatic etiology is the most frequent cause of digital aneurysms. Risk factors for pseudoaneurysms include sharp force trauma and alterations of the coagulation pathways, as in the case presented. CONCLUSION: the pseudoaneurysm of a digital artery is a rare pathology with great variability of therapeutic management. Surgical resection of the lesion with vascular flow reconstruction is the recommended treatment.


INTRODUCCIÓN: los aneurismas son dilataciones vasculares localizadas y permanentes de una arteria; en los pseudoaneurismas, las capas normales del vaso sanguíneo son reemplazadas por tejido fibroso. Debido a su baja incidencia, así como el desafío diagnóstico y terapéutico que representan; nuestro objetivo es presentar el caso clínico de un pseudoaneurisma de una arteria digital de la mano y realizar una revisión sistemática sobre dicha patología. MATERIAL Y MÉTODOS: búsqueda bibliográfica en Medline, utilizando los términos "arteria digital" y "aneurisma". Se incorporaron estudios de patología de dilatación vascular que afecte la mano y los dedos. Se excluyeron trabajos con patología de afección proximal de la mano. PRESENTACIÓN DE CASO: paciente femenino de 79 años de edad, que posterior a herida cortante de quinto dedo de mano izquierda, desarrolla tumoración necrótica de rápido crecimiento. Contaba con ecografía y angiografía que sugerían hematoma. Se decidió manejo quirúrgico, durante el cual se observó que la tumoración involucraba arteria digital colateral cubital del quinto dedo. Se resecó lesión y segmento arterial involucrado. Cursó postquirúrgico sin complicaciones. Se confirmó el diagnóstico histopatológico de pseudoaneurisma de la lesión. DISCUSIÓN: la etiología traumática es la causa más frecuente de los aneurismas digitales. Los factores de riesgo para los pseudoaneurismas incluyen lesiones penetrantes y alteraciones de la cascada de coagulación, como en el caso presentado. CONCLUSIÓN: el pseudoaneurisma de una arteria digital es una patología rara y con gran variabilidad de manejo terapéutico. La resección quirúrgica de la lesión con la reconstrucción del flujo vascular, es el tratamiento recomendado.


Assuntos
Falso Aneurisma , Aneurisma , Neoplasias , Feminino , Humanos , Idoso , Falso Aneurisma/diagnóstico , Falso Aneurisma/cirurgia , Falso Aneurisma/etiologia , Artérias , Aneurisma/complicações , Ultrassonografia/efeitos adversos , Neoplasias/complicações
2.
J Orthop Case Rep ; 9(5): 3-6, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-32547992

RESUMO

INTRODUCTION: Marfan's syndrome is a hereditary, autosomal dominant multisystemic disorder involving connective tissue. Bilateral extensor carpi ulnaris and ulnar nerve (UN) instability is rare, usually caused by the alteration of structures mainly formed by connective tissue. The association between Marfan's syndrome and bilateral instability of UN and extensor carpi ulnaris has never been reported. CASE REPORT: We present the case of a 38-year-old female with no history of trauma, diagnosed with Marfan's syndrome, who developed bilateralinstability of the UN and extensor carpi ulnaris. Bilateral UN transposition and extensor carpi ulnaris tenoplasty were performed. CONCLUSION: Atraumatic bilateral instability of UN and extensor carpi ulnaris is a new rare clinical profile caused by Marfan's syndrome whether standard treatment is successful in a long-term basis in these particular cases of collagen intrinsic pathology remains unclear.

3.
Case Rep Orthop ; 2018: 8351205, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29682379

RESUMO

Extensor tendon ruptures due to volar plating in distal radius fractures have mostly been described in relation with technique failures such as screw prominence and drill penetration. We report the case of a 71-year-old female with a C2 distal radius fracture with severe dorsal metaphyseal comminution. The patient underwent surgical treatment with reduction of the large fragments and fixation with a volar locking plate; the small dorsal metaphyseal nonarticular fragments were not reduced. Six months later, the patient developed extensor digitorum communis (EDC) rupture and extensor indicis proprius (EIP) laceration in coincidence with the dorsal comminution turned into a bony spur. The possible association between the extensor tendon injury and the dorsal residual metaphyseal bony spur in the distal radius fractures is unusual but should be taken into account in fracture patterns presenting dorsal comminution.

4.
Bone Joint J ; 96-B(4): 530-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24692623

RESUMO

We retrospectively evaluated the clinical and radiological outcomes of a consecutive cohort of patients aged > 70 years with a displaced fracture of the olecranon, which was treated non-operatively with early mobilisation. We identified 28 such patients (27 women) with a mean age of 82 years (71 to 91). The elbow was initially immobilised in an above elbow cast in 90° of flexion of the elbow for a mean of five days. The cast was then replaced by a sling. Active mobilisation was encouraged as tolerated. No formal rehabilitation was undertaken. At a mean follow-up of 16 months (12 to 26), the mean ranges of flexion and extension were 140° and 15° respectively. On a visual analogue scale of 1 (no pain) to 10, the mean pain score was 1 (0 to 8). Of the original 28 patients 22 developed nonunion, but no patients required surgical treatment. We conclude that non-operative functional treatment of displaced olecranon fractures in the elderly gives good results and a high rate of satisfaction.


Assuntos
Fixação de Fratura/métodos , Fraturas Ósseas/cirurgia , Olécrano/lesões , Atividades Cotidianas , Idoso , Idoso de 80 Anos ou mais , Moldes Cirúrgicos , Articulação do Cotovelo/fisiopatologia , Feminino , Fixação de Fratura/efeitos adversos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/reabilitação , Humanos , Masculino , Olécrano/diagnóstico por imagem , Satisfação do Paciente , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Lesões no Cotovelo
5.
J Hand Surg Eur Vol ; 39(7): 755-60, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-24401740

RESUMO

The present study was performed to test the null hypothesis on no difference in stability of fixation after volar plating of intra-articular distal radius fractures (AO C2-C3) with either locking smooth pegs or locking screws in a clinical setting. A retrospective evaluation included adult patients with C2-C3 AO fractures treated with a volar plate with locking smooth pegs or locking screws. Radiographic assessment was performed to evaluate extra- and intra-articular parameters in the early postoperative period and after bone union. Twenty-seven consecutive patients were included. Thirteen cases had fixation with locking screws and 14 had fixation with locking smooth pegs. Both groups had bone fragment displacement after fixation. However, there were no significant differences between the groups either in extra- or intra-articular parameters defined by Kreder et al. (1996). Our study shows that, in a clinical setting, there is no difference in stability fixation between locking screws or smooth locking pegs in C2-C3 distal radius fractures.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/instrumentação , Fraturas Intra-Articulares/cirurgia , Placa Palmar/cirurgia , Fraturas do Rádio/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Fraturas Intra-Articulares/diagnóstico por imagem , Fraturas Intra-Articulares/fisiopatologia , Masculino , Pessoa de Meia-Idade , Radiografia , Fraturas do Rádio/diagnóstico por imagem , Fraturas do Rádio/fisiopatologia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento , Articulação do Punho
6.
Chir Main ; 32(3): 186-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23665311

RESUMO

Bilateral rupture of the extensor pollicis longus (EPL) is a rare entity and the few cases that have been reported were associated with an underlying systemic condition such as rheumatoid arthritis or following an injury. We present the case of a patient who was referred to us with a spontaneous rupture of the EPL tendon of the right wrist and that of the left side observed 2 months after tenosynovectomy. The patient had not any pathologic condition or evidence of trauma in both wrists. In the left side, he was operated on and a tenolysis and subcutaneous tendon transposition was performed. Despite this preventive surgery, the patient suffered from a tendon rupture. The possible causes of surgery failure are discussed.


Assuntos
Traumatismos dos Tendões/etiologia , Traumatismos dos Tendões/cirurgia , Tenossinovite/complicações , Tenossinovite/cirurgia , Polegar/cirurgia , Adulto , Diagnóstico Tardio , Seguimentos , Força da Mão , Humanos , Masculino , Articulação Metacarpofalângica/cirurgia , Reoperação , Ruptura Espontânea , Traumatismos dos Tendões/diagnóstico , Tenossinovite/diagnóstico , Resultado do Tratamento , Punho/cirurgia
7.
Chir Main ; 28(5): 326-9, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19766035

RESUMO

Functional results after resection-reconstruction operated at the same time. Desmoid tumors, also known as aggressive fibromatosis, are benign locally aggressive tumors with a high rate of recurrence. Most authors recommend surgical treatment with wide-free margin. Achieving margins of normal tissue around an upper extremity lesion without creating significant functional compromise is frequently difficult. Therefore, functional reconstructive surgery is important, considering that for most patients treated for these tumors, the life expectancy is high and considering also that wide resection can affect the function and the aesthetics as well. We present a case of aggressive fibromatosis in the proximal third of the forearm treated by wide resection and reconstructive surgery in one single procedure, with an acceptable functional result with no evidence of recurrence at 3 years of follow-up.


Assuntos
Fibromatose Agressiva/cirurgia , Antebraço , Neoplasias de Tecidos Moles/cirurgia , Feminino , Humanos , Procedimentos de Cirurgia Plástica/métodos , Recuperação de Função Fisiológica , Adulto Jovem
8.
Chir Main ; 28(1): 18-25, 2009 Feb.
Artigo em Francês | MEDLINE | ID: mdl-19124265

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the results and complications of locked palmar plating in patients with articular fracture of the distal radius. METHODS: Twenty-two patients were reviewed retrospectively. The average age was 68 years. All fractures were classified as Type C according to the AO classification. Clinical and functional examination including range of motion, grip strength, pain and return to previous activities were assessed. Loss of radial height, radial inclination, palmar tilt and ulnar variance were evaluated with preoperative and postoperative radiographs. RESULTS: At an average follow-up of 10 months, the range of motion was 124 degrees in flexion and extension and 178 degrees in pronation and supination. Grip strength was 80% of the opposite side. Fifteen patients were free of pain. Three patients suffered tenosynovitis of the extensor tendons. Radiographic measurements averaged 11 mm radial height, 21 degrees radial inclination, 4 degrees palmar tilt and 1 mm ulnar variance. CONCLUSIONS: The result of this study showed that locked palmar plating of articular distal radius fractures is effective even in cases of metaphyseal comminution with a low rate of complications.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas do Rádio/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Estudos Retrospectivos , Articulação do Punho/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA