Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ann Thorac Surg ; 99(5): 1713-8, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25754963

RESUMO

BACKGROUND: Patients with end-stage heart failure possess many attributes that place them at risk for prolonged mechanical ventilation (MV). However, there are only limited data on MV support among children after ventricular assist device (VAD) implantation. We report the duration of MV after VAD placement, indications for respiratory support in the postimplantation period, and associated patient factors. METHODS: This single-center retrospective study included 43 consecutive children (aged <18 years) with end-stage heart failure who were supported with a VAD as a bridge to transplantation from January 2005 to December 2011. Multivariable analysis was performed using the multiple Poisson regression model for the duration of MV. RESULTS: Overall, 33% (n = 14) remained on MV until heart transplant or death. Of those requiring pre-VAD extracorporeal membrane oxygenation (ECMO) support, 63% (n = 12 of 19) remained on MV until heart transplant or death compared with 8% (n = 2 of 24) among those not on ECMO before VAD (p < 0.001). Patients with moderate or severe mitral regurgitation while on VAD support had 1.7-times more MV days compared with those with none or trivial on-VAD mitral regurgitation. In addition, previous support on ECMO, those with moderate or severe tricuspid regurgitation, and those with only left VAD implants had an increased risk of prolonged MV. CONCLUSIONS: Our results suggest that VAD recipients previously supported on ECMO, those with moderate or severe mitral regurgitation, moderate or severe tricuspid regurgitation, and those with only left VAD implants had an increased risk of prolonged MV. Future studies in larger cohorts are necessary to confirm the findings from this single-institutional experience.


Assuntos
Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Insuficiência Cardíaca/terapia , Coração Auxiliar , Respiração Artificial/estatística & dados numéricos , Criança , Pré-Escolar , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Transplante de Coração , Humanos , Lactente , Masculino , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/terapia , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
2.
Pediatr Crit Care Med ; 15(4): e175-82, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24622165

RESUMO

OBJECTIVE: Investigate whether anti-Factor Xa levels are associated with the need for change of circuit/membrane oxygenator secondary to thrombus formation in pediatric patients. DESIGN AND SETTINGS: Retrospective single institution study. PATIENTS: Retrospective record review of 62 pediatric patients supported with extracorporeal membrane oxygenation from 2009 to 2011. INTERVENTIONS: Data on standard demographic characteristics, indications for extracorporeal membrane oxygenation, duration of extracorporeal membrane oxygenation, activated clotting time measurements, anti-Factor Xa measurements, and heparin infusion rate were collected. Generalized linear models were used to associate anti-Factor Xa concentrations and need for change of either entire circuit/membrane oxygenator secondary to thrombus formation. MEASUREMENTS AND MAIN RESULTS: Sixty-two patients met study inclusion criteria. No-circuit change was required in 45 of 62 patients. Of 62 patients, 17 required change of circuit/membrane oxygenator due to thrombus formation. Multivariate analysis of daily anti-Factor Xa measurements throughout duration of extracorporeal membrane oxygenation support estimated a mean anti-Factor Xa concentration of 0.20 IU/mL (95% CI, 0.16, 0.24) in no-complete-circuit group that was significantly higher than the estimated concentration of 0.13 IU/mL (95% CI, 0.12, 0.14) in complete-circuit group (p = 0.001). A 0.01 IU/mL decrease in anti-Factor Xa increased odds of need for circuit/membrane oxygenator change by 5% (odds ratio = 1.105; 95% CI, 1.00, 1.10; p = 0.044). Based on the observed anti-Factor Xa concentrations, complete-circuit group had 41% increased odds for requiring circuit/membrane oxygenator change compared with no-complete-circuit group (odds ratio = 1.41; 95% CI, 1.01, 1.96; p = 0.044). Mean daily activated clotting time measurement (p = 0.192) was not different between groups, but mean daily heparin infusion rate (p < 0.001) was significantly different between the two groups. CONCLUSIONS: Higher anti-Factor Xa concentrations were associated with freedom from circuit/membrane oxygenator change due to thrombus formation in pediatric patients during extracorporeal membrane oxygenation support. Activated clotting time measurements did not differ significantly between groups with or without circuit/membrane oxygenator change. This is the first study to link anti-Factor Xa concentrations with a clinically relevant measure of thrombosis in pediatric patients during extracorporeal membrane oxygenation support. Further prospective study is warranted.


Assuntos
Anticoagulantes/administração & dosagem , Oxigenação por Membrana Extracorpórea/métodos , Fator Xa/metabolismo , Heparina/administração & dosagem , Trombose/sangue , Adolescente , Criança , Pré-Escolar , Oxigenação por Membrana Extracorpórea/instrumentação , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos , Trombose/prevenção & controle , Tempo de Coagulação do Sangue Total , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA