Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
1.
J Biomed Mater Res B Appl Biomater ; 112(8): e35459, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39082218

RESUMO

Poly(3-hydroxybutyrate-co-3-hydroxyvalerate) (PHBV) nanofibers embedded with borate glasses of 45B5 composition doped with Co2+, Cu2+, and Zn2 +(46.1 B2O326.9-X CaO24.4 Na2O2.6 P2O5, X CoO/CuO/ZnO mol % (X = 0-5)) were produced by electrospinning for wound healing applications. Prior to their addition, the glasses exhibited two broad halos typical of a vitreous borate network, which were mainly composed of ring-type metaborate structural units. The particle distribution in the PHBV nanofibers embedded with 45B5 borate bioactive glasses is present in isolated and agglomerated states, being partially coated by a polymeric layer-except for the cobalt-doped glass, which resulted in a successful encapsulation with 100% embedding efficiency. The incorporation of the glasses reduced the PHBV crystallinity degree and its decomposition temperature, as well as its mechanical properties, including Young's modulus, tensile strength, and elongation at break. The neat PHBV fibers and those containing the cobalt-doped glasses demonstrated great cytocompatibility with human keratinocytes (HaCat), as suggested by the high cell viability after 7 days of exposure. Further studies are needed to fully understand the wound healing potential of these fibers, but our results significantly contribute to the area.


Assuntos
Bandagens , Boratos , Cobalto , Cobre , Poliésteres , Zinco , Humanos , Cobre/química , Cobalto/química , Poliésteres/química , Boratos/química , Zinco/química , Vidro/química , Teste de Materiais , Cicatrização , Nanofibras/química , Linhagem Celular , Poli-Hidroxibutiratos
2.
Int J Dent ; 2024: 6628146, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38938694

RESUMO

This study aimed to evaluate the effect of autoclave sterilization on the integrity and instruments' fracture number after multiple uses and cyclic fatigue of the original WaveOne Gold (Dentsply Sirona Endodontics) compared to four replica-like instruments (TF4-Gold, Roll-Wave-Gold, W-File, and Micro-Gold). The instruments were analyzed by scanning electron microscope (SEM) before being used in root canal instrumentation (baseline). One hundred and fifty human molars, freshly extracted for orthodontic reasons or periodontal disease and with severe curvature (between 30° and 60°), were used. Fifty teeth were instrumented with 10 instruments from each group and were evaluated for integrity. After sterilization in an autoclave, the instruments were analyzed by SEM. This procedure was repeated twice more, totaling three rounds of instrumentation, sterilization, and SEM analysis. Ten unused instruments from each group were evaluated for resistance to cyclic fatigue in a static test using a motor and a device simulating a canal with a 60° curvature angle. The instruments were driven by the motor until separation, visually verified, and the time measured in seconds. Data were analyzed by Chi-square, one-way ANOVA, and Tukey analysis, considering a significance level of 5%. It was found that there was no statistically significant difference between the groups tested in the effect of sterilization on the number of uses. The SEM analysis showed distortions in the instruments after the 3rd use. There was a statistically significant difference in the cyclic fatigue test between the results of WaveOne Gold, TF4 Gold, and Roll Wave Gold compared to W File and Micro Gold (P < 0.0001) and a statistically significant difference between the W File and Micro Gold groups (P < 0.0001). In conclusion, this study affirmed that WaveOne Gold, TF4-Gold, and Roll-Wave-Gold instruments exhibit comparable cyclic fatigue resistance. Besides, all examined instruments can be reliably employed for up to two cases.

3.
Sci Rep ; 14(1): 13262, 2024 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-38858417

RESUMO

The purpose of this study was to evaluate the fatigue survival of 5Y-PSZ zirconia infiltrated with an experimental glass and bonded onto dentin analogues. Disc-shaped specimens of a 5Y-PSZ (Katana UTML Kuraray Noritake) were cemented onto dentin analogs (NEMA G10) and divided into four groups (n = 15): Zctrl Group (control, without infiltration); Zglz Group (Glaze, compression surface); Zinf-comp Group (Experimental Glass, compression surface); Zinf-tens Group (Experimental Glass, tension surface). Surface treatments were varied. Cyclic fatigue loading, oblique transillumination, stereomicroscope examination, and scanning electron microscopy were performed. Fatigue data were analyzed (failure load and number of cycles) using survival analysis (Kaplan-Meier and Log-Rank Mantel-Cox). There was no statistically significant difference in fatigue survival between the Zglz, Zctrl, and Zinf-comp groups. The Zinf-tens group presented a significantly higher failure load when compared to the other groups and exhibited a different failure mode. The experimental glass effectively infiltrated the zirconia, enhancing structural reliability, altering the failure mode, and improving load-bearing capacity over more cycles, particularly in the group where the glass was infiltrated into the tensile surface of the zirconia. Glass infiltration into 5Y-PSZ zirconia significantly enhanced structural reliability and the ability to withstand loads over an increased number of cycles. This approach has the potential to increase the durability of zirconia restorations, reducing the need for replacements and save time and resources, promoting efficiency in clinical practice.


Assuntos
Dentina , Vidro , Teste de Materiais , Zircônio , Zircônio/química , Vidro/química , Dentina/química , Humanos , Microscopia Eletrônica de Varredura , Propriedades de Superfície
4.
Materials (Basel) ; 17(7)2024 Mar 26.
Artigo em Inglês | MEDLINE | ID: mdl-38612010

RESUMO

The present study aimed to characterize the microstructure of a temporary 3D printing polymer-based composite material (Resilab Temp), evaluating its optical properties and mechanical behavior according to different post-curing times. For the analysis of the surface microstructure and establishment of the best printing pattern, samples in bar format following ISO 4049 (25 × 10 × 3 mm) were designed in CAD software (Rhinoceros 6.0), printed on a W3D printer (Wilcos), and light-cured in Anycubic Photon for different lengths of time (no post-curing, 16 min, 32 min, and 60 min). For the structural characterization, analyses were carried out using Fourier transform infrared spectroscopy (FT-IR) and scanning electron microscopy (SEM). The mechanical behavior of this polymer-based composite material was determined based on flexural strength tests and Knoop microhardness. Color and translucency analysis were performed using a spectrophotometer (VITA Easy Shade Advanced 4.0), which was then evaluated in CIELab, using gray, black, and white backgrounds. All analyses were performed immediately after making the samples and repeated after thermal aging over two thousand cycles (5-55 °C). The results obtained were statistically analyzed with a significance level of 5%. FT-IR analysis showed about a 46% degree of conversion on the surface and 37% in the center of the resin sample. The flexural strength was higher for the groups polymerized for 32 min and 1 h, while the Knoop microhardness did not show a statistical difference between the groups. Color and translucency analysis also did not show statistical differences between groups. According to all of the analyses carried out in this study, for the evaluated material, a post-polymerization time of 1 h should be suggested to improve the mechanical performance of 3D-printed devices.

5.
J Mech Behav Biomed Mater ; 154: 106533, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38598918

RESUMO

The present work aims to develop a production method of pre-sintered zirconia-toughened-alumina (ZTA) composite blocks for machining in a computer-aided design and computer-aided manufacturing (CAD-CAM) system. The ZTA composite comprised of 80% Al2O3 and 20% ZrO2 was synthesized, uniaxially and isostatically pressed to generate machinable CAD-CAM blocks. Fourteen green-body blocks were prepared and pre-sintered at 1000 °C. After cooling and holder gluing, a stereolithography (STL) file was designed and uploaded to manufacture disk-shaped specimens projected to comply with ISO 6872:2015. Seventy specimens were produced through machining of the blocks, samples were sintered at 1600 °C and two-sided polished. Half of the samples were subjected to accelerated autoclave hydrothermal aging (20h at 134 °C and 2.2 bar). Immediate and aged samples were characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD). Optical and mechanical properties were assessed by reflectance tests and by biaxial flexural strength test, Vickers indentation and fracture toughness, respectively. Samples produced by machining presented high density and smooth surfaces at SEM evaluation with few microstructural defects. XRD evaluation depicted characteristic peaks of alpha alumina and tetragonal zirconia and autoclave aging had no effect on the crystalline spectra of the composite. Optical and mechanical evaluations demonstrated a high masking ability for the composite and a characteristic strength of 464 MPa and Weibull modulus of 17, with no significant alterations after aging. The milled composite exhibited a hardness of 17.61 GPa and fracture toughness of 5.63 MPa m1/2, which remained unaltered after aging. The synthesis of ZTA blocks for CAD-CAM was successful and allowed for the milling of disk-shaped specimens using the grinding method of the CAD-CAM system. ZTA composite properties were unaffected by hydrothermal autoclave aging and present a promising alternative for the manufacture of infrastructures of fixed dental prostheses.


Assuntos
Óxido de Alumínio , Cerâmica , Teste de Materiais , Óxido de Alumínio/química , Cerâmica/química , Propriedades de Superfície , Zircônio/química , Desenho Assistido por Computador , Materiais Dentários
6.
J Biomater Sci Polym Ed ; 35(10): 1493-1510, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38569077

RESUMO

In recent years, there has been a notable surge of interest in hybrid materials within the biomedical field, particularly for applications in bone repair and regeneration. Ceramic-polymeric hybrid scaffolds have shown promising outcomes. This study aimed to synthesize bioactive glass (BG-58S) for integration into a bioresorbable polymeric matrix based on PDLLA, aiming to create a bioactive scaffold featuring stable pH levels. The synthesis involved a thermally induced phase separation process followed by lyophilization to ensure an appropriate porous structure. BG-58S characterization revealed vitreous, bioactive, and mesoporous structural properties. The scaffolds were analyzed for morphology, interconnectivity, chemical groups, porosity and pore size distribution, zeta potential, pH, in vitro degradation, as well as cell viability tests, total protein content and mineralization nodule production. The PDLLA scaffold displayed a homogeneous morphology with interconnected macropores, while the hybrid scaffold exhibited a heterogeneous morphology with smaller diameter pores due to BG-58S filling. The hybrid scaffold also demonstrated a pH buffering effect on the polymer surface. In addition to structural characteristics, degradation tests indicated that by incorporating BG-58S modified the acidic degradation of the polymer, allowing for increased total protein production and the formation of mineralization nodules, indicating a positive influence on cell culture.


Assuntos
Regeneração Óssea , Cerâmica , Vidro , Poliésteres , Alicerces Teciduais , Cerâmica/química , Alicerces Teciduais/química , Regeneração Óssea/efeitos dos fármacos , Vidro/química , Porosidade , Poliésteres/química , Materiais Biocompatíveis/química , Concentração de Íons de Hidrogênio , Humanos , Sobrevivência Celular/efeitos dos fármacos , Teste de Materiais
7.
J Biomed Mater Res B Appl Biomater ; 112(2): e35380, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38348496

RESUMO

Zirconia implants are gaining attention as a viable alternative to titanium implants due to their comparable osseointegration development, improved soft tissue adaptation, and enhanced aesthetics. An encouraging avenue for improving zirconia implant properties involves the potential application of bioactive coatings to their surfaces. These coatings have shown potential for inducing hydroxyapatite formation, crucial for bone proliferation, and improving implant mechanical properties. This study aimed to evaluate the effect of coating zirconia implants with two bioactive glasses, 45S5 and BioK, on osteogenesis in vitro and osseointegration in vivo. Zirconia samples and implants were prepared using Zpex zirconia powder and blocks, respectively. The samples were divided into three groups: polished zirconia (ZRC), zirconia coated with 45S5 bioglass (Z + 45S5), and zirconia coated with BioK glass (Z + BK). Coatings were applied using a brush and sintered at 1200°C. Chemical analysis of the coatings was carried out using x-ray diffraction and Fourier Transform Infrared Spectroscopy. Surface topography and roughness were characterized using scanning electron microscopy and a roughness meter. In vitro experiments used mesenchymal cells from Wistar rat femurs, and the coated zirconia implants were found to promote cell viability, protein synthesis, alkaline phosphatase activity, and mineralization, indicating enhanced osteogenesis. In vivo experiments with 18 rats showed positive results for bone formation and osseointegration through histological and histomorphometric analysis and a push-out test. The findings indicate that bioactive glass coatings have the potential to improve cell differentiation, bone formation, and osseointegration in zirconia implants.


Assuntos
Cerâmica , Implantes Dentários , Próteses e Implantes , Zircônio , Ratos , Animais , Ratos Wistar , Osseointegração , Propriedades de Superfície , Titânio/farmacologia , Titânio/química , Materiais Revestidos Biocompatíveis/farmacologia , Materiais Revestidos Biocompatíveis/química , Microscopia Eletrônica de Varredura
8.
J Esthet Restor Dent ; 36(1): 47-55, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37772362

RESUMO

OBJECTIVE: To evaluate the effect of different hydrofluoric acid concentrations and etching times on the surface, chemical composition and microstructure of lithium disilicate. MATERIAL AND METHODS: Ninety specimens of pressed lithium disilicate (LDS) were obtained (IPS e.max Press, Rosetta SP and LiSi Press). The specimens of each material were divided in two groups according to the hydrofluoric acid concentration: 5% and 10% (n = 15/group), and subdivided according to the etching time: 20, 40 and 60 s (n = 5/group). Crystalline evaluations and chemical composition were performed through x-ray diffraction (XRD) and energy-dispersive x-ray spectroscopy (EDS), respectively. Microstructural analyses were performed by scanning electron microscope (SEM), surface roughness (Ra), and material thickness removal evaluation. Thickness removal and Ra data were analyzed by ANOVA and Tukey test (p < 0.05). RESULTS: XRD demonstrated characteristic peaks of lithium disilicate crystals, lithium phosphate and of a vitreous phase for all materials. EDS identified different compositions and SEM confirmed different surface responses to acid etching protocols. Material and etching time influenced Ra and material thickness removal (p < 0.05). CONCLUSION: Hydrofluoric acid concentration and etching time affect the surface characteristics of LDS differently. LiSi Press presented higher resistance to hydrofluoric acid etching compared to e.max Press and Rosetta SP. CLINICAL SIGNIFICANCE: Applying the appropriate etching protocol is pivotal to avoid excessive material removal and to prevent jeopardize the mechanical and optical properties of the material.


Assuntos
Colagem Dentária , Ácido Fluorídrico , Ácido Fluorídrico/química , Teste de Materiais , Porcelana Dentária/química , Cerâmica/química , Propriedades de Superfície , Colagem Dentária/métodos , Cimentos de Resina/química
9.
J Biomed Mater Res B Appl Biomater ; 112(1): e35315, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-37589245

RESUMO

The development of bioactive membranes with bone repair properties is great interest in the field of tissue engineering. In this study, we aimed to fabricate and characterize a composite membrane composed of sol-gel synthesized bioceramics and electrospun polycaprolactone (PCL) fibers for bone tissue regeneration applications. The bioceramics were prepared using the sol-gel method with nitrate (N) and chloride (CL) as precursors. PCL and bioceramic solutions were electrospun to obtain ultrafine fiber mats. Raman spectroscopy, x-ray diffraction (XRD), Fourier Transform Infrared spectroscopy (FTIR), thermogravimetric analysis (TGA), and scanning electron microscopy (SEM) were used to characterize the materials. The results showed that both chlorinated and non-chlorinated bioceramics contained NBOs (non-bridge bonds) and crystallized the α-wollastonite phase, with the chlorinated version doing so at lower temperatures. In vitro tests were performed to evaluate cytotoxicity, cell adhesion, and mineralized matrix formation on the membranes. The composite membranes showed improved cell viability and promoted mineralization nodules formation. This study presents a promising approach for the development of bioactive membranes for bone tissue engineering, with potential applications in bone regeneration therapies.


Assuntos
Poliésteres , Engenharia Tecidual , Poliésteres/química , Engenharia Tecidual/métodos , Espectroscopia de Infravermelho com Transformada de Fourier , Osso e Ossos , Alicerces Teciduais/química , Materiais Biocompatíveis/química
10.
Int J Biol Macromol ; 254(Pt 2): 127826, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37926324

RESUMO

This paper explores the application of cross-linked cellulose beads as a sustainable and cost-effective support for the ZnO/SnO2/carbon xerogel hybrid photocatalyst. The application of the developed photocatalytic beads, named CB-Cat, was directed at a simultaneous adsorption/photocatalysis process, which was carried out under simulated sunlight. The characterization of the CB-Cat indicated a good dispersion of the photocatalyst of choice throughout the cellulose matrix, confirming its incorporation into the cellulose beads. Furthermore, it is possible to observe the presence of the photocatalyst on the surface of the CB-Cat, confirming its availability for the photonic activation process. The results showed that the simultaneous adsorption/photocatalysis process was optimal for enhancing the efficiency of methylene blue (MB) removal, especially when compared to the isolated adsorption process. Additionally, the regeneration of the CB-Cat between cycles was favorable toward the maintenance of the MB removal efficiency, as the process carried out without regeneration displayed significant efficiency drops between cycles. Finally, the mechanism evaluation evidenced that hydroxyl and superoxide radicals were the main responsible for the MB photocatalytic degradation during illumination with simulated sunlight.


Assuntos
Poluentes Químicos da Água , Óxido de Zinco , Carbono , Adsorção , Celulose , Luz Solar , Azul de Metileno
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA