Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 1288: 342177, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38220307

RESUMO

BACKGROUND: the chemometric processing of second-order chromatographic-spectral data is usually carried out with the aid of multivariate curve resolution-alternating least-squares (MCR-ALS). Recently, an alternative procedure was described based on the estimation of image moments for each data matrix and subsequent application of multiple linear regression after suitable variable selection. RESULTS: The analysis of both simulated and experimental data leads to the conclusion that the image moment method, although can cope with chromatographic lack of reproducibility across injections, it only performs well in the absence of uncalibrated interferents. MCR-ALS, on the other hand, provides good analytical results in all studied situations, whether the test samples contain uncalibrated interferents or not. SIGNIFICANCE: The results are useful to assess the real usefulness of newly proposed methodologies for second-order calibration in the case of chromatographic-spectral data sets, especially when samples contain unexpected chemical constituents.

2.
Anal Chim Acta ; 1266: 341354, 2023 Jul 25.
Artigo em Inglês | MEDLINE | ID: mdl-37244664

RESUMO

BACKGROUND: the chemometric processing of second-order chromatographic-spectral data is usually carried out with the aid of multivariate curve resolution-alternating least-squares (MCR-ALS). When baseline contributions occur in the data, the background profile retrieved with MCR-ALS may show abnormal lumps or negative dips at the position of the remaining component peaks. RESULTS: The phenomenon is shown to be due to remaining rotational ambiguity in the obtained profiles, as confirmed by the estimation of the boundaries of the range of feasible bilinear profiles. To avoid the abnormal features in the retrieved profile, a new background interpolation constraint is proposed and described in detail. Both simulated and experimental data are employed to support the need of the new MCR-ALS constraint. In the latter case, the estimated analyte concentrations agreed with those previously reported. SIGNIFICANCE: The developed procedure helps to reduce the extent of rotational ambiguity in the solution and to better interpret the results on physicochemical grounds.

3.
Talanta ; 197: 348-355, 2019 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-30771946

RESUMO

The endocrine disrupting chemicals bisphenol A (BPA) and 4-nonylphenol (NP) were simultaneously quantified through third-order/four-way calibration. Excitation-emission fluorescence matrix-kinetic (EEFM-K) third-order data were generated by measuring the EEFMs of these priority xenoestrogens as a function of reaction time during their Fenton degradation. Third-order/four-way calibration notably improves the sensitivity of the method and provides the required selectivity for quantifying analytes with critically overlapped fluorescence signals. In fact, collinearity between BPA and NP emission spectra prevented their quantification using EEFM second-order data and three-way PARAFAC (parallel factor analysis); however, the addition of a third instrumental mode allowed the correct chemometric modeling with four-way PARAFAC. In this way, the compliance of Kruskal's theorem extended to higher-order data was verified. The method was applied for the determination of the analytes in samples of different plastic materials, which are in contact with food and/or beverages. In these cases, where unmodelled constituents are present, good results for BPA were achieved with four-way PARAFAC, but the predictions for NP using this model were deficient. A better predictive capability for NP in real samples was achieved when either U-PLS/RTL (unfolded partial least-squares combined with residual trilinearization) or MCR-ALS (multivariate curve resolution with alternating least-squares) was applied for data processing, demonstrating the power of these latter models for the resolution of more complex systems.


Assuntos
Compostos Benzidrílicos/análise , Fluorescência , Contaminação de Alimentos/análise , Fenóis/análise , Plásticos/química , Cinética , Análise dos Mínimos Quadrados
4.
Talanta ; 189: 509-516, 2018 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-30086953

RESUMO

For the first time, a third-order/four-way system having instrumental modes depending on each other was experimentally generated and it was successfully resolved. Non-quadrilinear type 4 data, constituted by liquid chromatographic elution times (LC) and excitation-emission fluorescence matrices (EEFMs), were on-line measured using conventional equipment. Thus, third-order/four-way data, valuable for giving rise to highly sensitive and selective methods, were obtained minimizing significantly the experimental work and time, in comparison with the reported strategies for the acquisition of LC-EEFM data. The usefulness of MCR-ALS (multivariate curve resolution-alternating least square) for attaining reliable results from data with two mutually dependent instrumental modes, namely elution time and excitation wavelength modes, was established through the simultaneous quantitation of benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[a]pyrene. Limits of detection in the range 1.0-1.4 ng mL-1 were achieved for the target polycyclic aromatic hydrocarbons, allowing their determination in about 9 min per sample in leaves of different types of tea.

5.
J Chromatogr A ; 1527: 61-69, 2017 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-29102061

RESUMO

For the first time, third-order liquid chromatography with excitation-emission fluorescence matrix detection (LC-EEFM) data were generated on-line and chemometrically processed for the simultaneous quantitation of the heavy-polycyclic aromatic hydrocarbons fluoranthene, pyrene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, benzo[k]fluoranthene, benzo[a]pyrene, and dibenz[a,h]anthracene. The applied experimental strategy is very simple, and is based on the reduction of the linear flow rate by fitting a larger diameter connecting-tube between the column outlet and the fluorimetric detector. In this way, EEFMs were successfully recorded on-line, without involving a large total analysis time. Because in the studied system quadrilinearity was fulfilled, four-way parallel factor (PARAFAC) analysis was applied for data processing. The second-order advantage, which is an intrinsic property of data of at least second-order, allowed the quantification of the analytes in interfering media. Moreover, resolution of the system with a high degree of collinearity was achieved thanks to the third-order advantage. In addition to a selectivity improvement, third-order/four-way calibration increased the sensitivity, with limits of detection in the range of 0.4-2.9ngmL-1. After a solid-phase extraction procedure with C18 membranes, considerably lower concentrations (between 0.033-2.70ngmL-1) were determined in real waters, with most recoveries in the range 90-106%.


Assuntos
Técnicas de Química Analítica/métodos , Cromatografia Líquida , Monitoramento Ambiental/métodos , Hidrocarbonetos Policíclicos Aromáticos/análise , Poluentes Químicos da Água/análise , Técnicas de Química Analítica/instrumentação , Fluorescência , Fluorometria , Limite de Detecção , Extração em Fase Sólida , Água/química
6.
Talanta ; 165: 52-63, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28153292

RESUMO

For the first time, a simple and environmentally friendly third-order/four-way calibration was applied for the simultaneous determination of five heavy-polycyclic aromatic hydrocarbons (PAHs) in interfering environments. The kinetic evolution of the Fenton degradation of benzo[a]pyrene, dibenz[a,h]anthracene, benzo[b]fluoranthene, benzo[k]fluoranthene and benz[a]anthracene was followed by recording full excitation-emission fluorescence matrices (EEFMs) of the samples at different reaction times, obtaining third-order EEFM-kinetic (EEFM-K) data. The sensitivity of the method was increased by carrying out the reaction in the presence of methyl-ß-cyclodextrin. The four-way parallel factor (PARAFAC) algorithm, which was used for data processing, exploits the second-order advantage, allowing analyte concentrations to be estimated even in the presence of an uncalibrated fluorescent background. The clear superiority of the applied approach in comparison with second-order/three-way calibration performed with unreacting EEFMs is demonstrated, using two sets of samples with foreign compounds with particular spectral profiles. In one of the latter sets, the existence of a third-order advantage was explored and discussed. The feasibility to directly determine parts-per-trillion concentration levels of PAHs after a very simple solid-phase extraction with C18 membranes is established with natural water samples containing uncalibrated constituents.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA