Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Arq Bras Cardiol ; 117(5): 1018-1027, 2021 11.
Artigo em Inglês, Português | MEDLINE | ID: mdl-34817012

RESUMO

BACKGROUND: C-reactive protein (CRP) is an inflammation biomarker that can be a predictor of adverse events in cardiovascular procedures. Its use in the assessment of long-term prognosis of transcatheter aortic valve implantation (TAVI) is still incipient. OBJECTIVE: To evaluate CRP as a prognostic marker in the first year after TAVI in aortic stenosis (AoS). METHODS: CRP was assessed on the first postoperative week in a retrospective cohort of patients with AoS. Pre- and post- CRP levels were correlated with mortality, and predictors of 1-year mortality were investigated. Multivariate Cox regression was performed to identify independent factors of 1-year mortality. RESULTS: This study evaluated 130 patients who underwent TAVI, with median age of 83 years, and 49% of women. High pre-TAVI CRP (> 0.5 mg/dL) was observed in 34.5% of the cases. Peak CRP was 7.0 (5.3-12.1) mg/dL no quarto dia. The rate of 1-year mortality was 14.5% (n = 19), being greater in the groups with high pre-TAVI CRP (68.8% vs 29.1%; p = 0,004) and with peak CRP ≥ 10.0 mg/dL (64.7% vs 30.8%; p = 0,009). Independent predictors of mortality were acute renal failure (ARF) (hazard ratio [HR] = 7.43; 95% confidence interval [95%CI], 2.1-24.7; p = 0,001), high pre-TAVI CRP (HR 4.15; 95%CI, 1.3-12.9; p = 0.01), and large blood transfusion [HR 4,68; 1,3-16,7; p = 0.02]. CONCLUSIONS: High pre-TAVI CRP showed to be an independent predictor of 1-year mortality, as well as the presence of ARF and large blood transfusions.


FUNDAMENTO: A proteína C-reativa (PCR) é um biomarcador de inflamação preditor de eventos adversos em procedimentos cardiovasculares. Na avaliação do implante da válvula aórtica transcateter (transcatheter aortic valve implantation, TAVI) em relação ao prognóstico de longo prazo ainda é incipiente. OBJETIVO: Avaliar a PCR como marcador prognóstico no primeiro ano pós-TAVI na estenose aórtica (EAo). MÉTODOS: A PCR foi avaliada na primeira semana do peroperatório numa coorte de casos retrospectiva com EAo. Correlacionou-se a PCR pré- e pós-TAVI com a mortalidade e foram pesquisados fatores preditores de mortalidade em 1 ano. Realizada regressão de Cox multivariada para identificar os preditores independentes de óbito em 1 ano. RESULTADOS: Estudados 130 pacientes submetidos a TAVI, com mediana de idade de 83 anos, sendo 49% deles do sexo feminino. A PCR pré-TAVI elevada (> 0,5 mg/dL) ocorreu em 34,5% dos casos. O pico de PCR foi 7,0 (5,3-12,1) mg/dL no quarto dia. A mortalidade em 1 ano foi 14,5% (n = 19), sendo maior nos grupos com PCR pré-TAVI elevada (68,8% vs 29,1%; p = 0,004) e pico de PCR ≥ 10,0 mg/dL (64,7% vs 30,8%; p = 0,009). Os fatores preditores independentes de mortalidade foram insuficiência renal aguda (IRA) [razão de risco (RR) = 7,43; intervalo de confiança de 95% (IC95%), 2,1-24,7; p = 0,001], PCR pré-TAVI elevada [RR = 4,15; IC95%, 1,3-12,9; p=0,01] e hemotransfusão volumosa [HR = 4,68; 1,3-16,7; p = 0,02]. CONCLUSÕES: A PCR pré-TAVI elevada mostrou-se fator preditor independente de mortalidade no primeiro ano, assim como a ocorrência de IRA e hemotransfusões volumosas.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Proteína C-Reativa/análise , Feminino , Humanos , Masculino , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
2.
Arq. bras. cardiol ; 117(5): 1018-1027, nov. 2021. tab, graf
Artigo em Inglês, Português | LILACS | ID: biblio-1350022

RESUMO

Resumo Fundamento: A proteína C-reativa (PCR) é um biomarcador de inflamação preditor de eventos adversos em procedimentos cardiovasculares. Na avaliação do implante da válvula aórtica transcateter (transcatheter aortic valve implantation, TAVI) em relação ao prognóstico de longo prazo ainda é incipiente. Objetivo: Avaliar a PCR como marcador prognóstico no primeiro ano pós-TAVI na estenose aórtica (EAo). Métodos: A PCR foi avaliada na primeira semana do peroperatório numa coorte de casos retrospectiva com EAo. Correlacionou-se a PCR pré- e pós-TAVI com a mortalidade e foram pesquisados fatores preditores de mortalidade em 1 ano. Realizada regressão de Cox multivariada para identificar os preditores independentes de óbito em 1 ano. Resultados: Estudados 130 pacientes submetidos a TAVI, com mediana de idade de 83 anos, sendo 49% deles do sexo feminino. A PCR pré-TAVI elevada (> 0,5 mg/dL) ocorreu em 34,5% dos casos. O pico de PCR foi 7,0 (5,3-12,1) mg/dL no quarto dia. A mortalidade em 1 ano foi 14,5% (n = 19), sendo maior nos grupos com PCR pré-TAVI elevada (68,8% vs 29,1%; p = 0,004) e pico de PCR ≥ 10,0 mg/dL (64,7% vs 30,8%; p = 0,009). Os fatores preditores independentes de mortalidade foram insuficiência renal aguda (IRA) [razão de risco (RR) = 7,43; intervalo de confiança de 95% (IC95%), 2,1-24,7; p = 0,001], PCR pré-TAVI elevada [RR = 4,15; IC95%, 1,3-12,9; p=0,01] e hemotransfusão volumosa [HR = 4,68; 1,3-16,7; p = 0,02]. Conclusões: A PCR pré-TAVI elevada mostrou-se fator preditor independente de mortalidade no primeiro ano, assim como a ocorrência de IRA e hemotransfusões volumosas.


Abstract Background: C-reactive protein (CRP) is an inflammation biomarker that can be a predictor of adverse events in cardiovascular procedures. Its use in the assessment of long-term prognosis of transcatheter aortic valve implantation (TAVI) is still incipient. Objective: To evaluate CRP as a prognostic marker in the first year after TAVI in aortic stenosis (AoS). Methods: CRP was assessed on the first postoperative week in a retrospective cohort of patients with AoS. Pre- and post- CRP levels were correlated with mortality, and predictors of 1-year mortality were investigated. Multivariate Cox regression was performed to identify independent factors of 1-year mortality. Results: This study evaluated 130 patients who underwent TAVI, with median age of 83 years, and 49% of women. High pre-TAVI CRP (> 0.5 mg/dL) was observed in 34.5% of the cases. Peak CRP was 7.0 (5.3-12.1) mg/dL no quarto dia. The rate of 1-year mortality was 14.5% (n = 19), being greater in the groups with high pre-TAVI CRP (68.8% vs 29.1%; p = 0,004) and with peak CRP ≥ 10.0 mg/dL (64.7% vs 30.8%; p = 0,009). Independent predictors of mortality were acute renal failure (ARF) (hazard ratio [HR] = 7.43; 95% confidence interval [95%CI], 2.1-24.7; p = 0,001), high pre-TAVI CRP (HR 4.15; 95%CI, 1.3-12.9; p = 0.01), and large blood transfusion [HR 4,68; 1,3-16,7; p = 0.02]. Conclusions: High pre-TAVI CRP showed to be an independent predictor of 1-year mortality, as well as the presence of ARF and large blood transfusions.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/metabolismo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Prognóstico , Proteína C-Reativa/análise , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
3.
Arq. bras. cardiol ; 109(6): 550-559, Dec. 2017. tab, graf
Artigo em Inglês | LILACS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-887985

RESUMO

Abstract Background: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. Objectives: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. Methods: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. Results: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). Conclusion: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Resumo Fundamento: O implante valvar aórtico transcateter (TAVI) está bem estabelecido, porém, o bloqueio atrioventricular, com necessidade de marca-passo definitivo (MPD), é complicação frequente. Objetivo: Determinar a incidência, preditores e desfechos clínicos de implante de MPD após TAVI, focando em como a evolução da fração de ejeção do ventrículo esquerdo (FEVE), após o TAVI, é afetada pelo MPD. Métodos: No registro brasileiro foram incluídos 819 pacientes submetidos a TAVI por estenose aórtica severa em 22 centros entre janeiro/2008 e janeiro/2015. Após exclusões, os preditores de implante de MPD foram avaliados em 670 pacientes por regressão multivariada. Análise da curva ROC foi utilizada para medir a habilidade dos preditores; p < 0,05 foi considerado significativo. Resultados: Aos 30 dias, 135 pacientes (20,1%) necessitaram de MPD. Tais pacientes eram mais velhos (82,5 vs. 81,1 anos; p = 0,047) e predominantemente homens (59,3% vs 45%; p = 0,003). A permanência hospitalar foi maior no Grupo MPD (média= 15,7 ± 25,7 vs. 11,8 ± 22,9 dias; p < 0,001), mas o implante não afetou morte por qualquer causa (26,7% vs. 25,6%; p = 0,80) nem morte cardiovascular (14,1% vs. 14,8%; p = 0,84). Por análise multivariada, a presença prévia de bloqueio de ramo direito (BRD) (OR, 6,19; 3,56-10,75; p ≤ 0,001), o uso da prótese CoreValve® (OR, 3,16; 1,74-5,72; p ≤ 0,001) e gradiente transaórtico basal > 50 mmHg (OR, 1,86; 1,08-3,2; p= 0,025) foram preditores de implante de MPD. O risco estimado de implante de MPD foi 4%, quando nenhum dos fatores de risco estava presente, e 63% na presença de todos. O modelo mostrou boa habilidade de prever a necessidade de MPD: 0,69 (IC95%: 0,64 - 0,74) na curva ROC. Subestudo de 287 ecocardiogramas durante o seguimento de 1 ano mostrou pior evolução da FEVE no Grupo MPD (p = 0,01). Conclusão: Em crianças de 6 a 11 anos, circunferência da cintura aumentada está associada à PA elevada, mesmo quando o IMC é normal. (Arq Bras Cardiol. 2017; [online].ahead print, PP.0-0)


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Marca-Passo Artificial/efeitos adversos , Bloqueio de Ramo/cirurgia , Próteses Valvulares Cardíacas/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Bloqueio Atrioventricular/cirurgia , Estenose da Valva Aórtica/cirurgia , Complicações Pós-Operatórias , Brasil , Fatores de Risco , Eletrocardiografia , Bloqueio Atrioventricular/fisiopatologia
4.
Arq Bras Cardiol ; 109(6): 550-559, 2017 Dec.
Artigo em Inglês, Português | MEDLINE | ID: mdl-29185614

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established procedure; however, atrioventricular block requiring permanent pacemaker implantation (PPI) is a common complication. OBJECTIVES: To determine the incidence, predictors and clinical outcomes of PPI after TAVI, focusing on how PPI affects left ventricular ejection fraction (LVEF) after TAVI. METHODS: The Brazilian Multicenter TAVI Registry included 819 patients submitted to TAVI due to severe aortic stenosis from 22 centers from January/2008 to January/2015. After exclusions, the predictors of PPI were assessed in 670 patients by use of multivariate regression. Analysis of the ROC curve was used to measure the ability of the predictors; p < 0.05 was the significance level adopted. RESULTS: Within 30 days from TAVI, 135 patients (20.1%) required PPI. Those patients were older (82.5 vs. 81.1 years; p = 0.047) and mainly of the male sex (59.3% vs 45%; p = 0.003). Hospital length of stay was longer in patients submitted to PPI (mean = 15.7 ± 25.7 vs. 11.8 ± 22.9 days; p < 0.001), but PPI affected neither all-cause death (26.7% vs. 25.6%; p = 0.80) nor cardiovascular death (14.1% vs. 14.8%; p = 0.84). By use of multivariate analysis, the previous presence of right bundle-branch block (RBBB) (OR, 6.19; 3.56-10.75; p ≤ 0.001), the use of CoreValve® prosthesis (OR, 3.16; 1.74-5.72; p ≤ 0.001) and baseline transaortic gradient > 50 mm Hg (OR, 1.86; 1.08-3.2; p = 0.025) were predictors of PPI. The estimated risk of PPI ranged from 4%, when none of those predictors was present, to 63%, in the presence of all of them. The model showed good ability to predict the need for PPI: 0.69 (95%CI: 0.64 - 0.74) in the ROC curve. The substudy of 287 echocardiograms during the 1-year follow-up showed worse LVEF course in patients submitted to PPI (p = 0.01). CONCLUSION: BRD prévio, gradiente aórtico médio > 50 mmHg e CoreValve® são preditores independentes de implante de MPD pós-TAVI. Ocorreu implante de MPD em aproximadamente 20% dos casos de TAVI, o que prolongou a internação hospitalar, mas não afetou a mortalidade. O implante de MPD afetou negativamente a FEVE pós-TAVI.


Assuntos
Valva Aórtica/cirurgia , Bloqueio Atrioventricular/cirurgia , Bloqueio de Ramo/cirurgia , Estimulação Cardíaca Artificial/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Marca-Passo Artificial/efeitos adversos , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/fisiopatologia , Brasil , Eletrocardiografia , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Fatores de Risco
5.
Catheter Cardiovasc Interv ; 89(3): 429-436, 2017.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1061861

RESUMO

OBJECTIVES: This study aimed to compare gender-related differences in outcomes of patients undergoing TAVI over a long-term follow-up period.BACKGROUND: Transcatheter aortic valve implantation (TAVI) has been considered the standard therapy for patients with inoperable or high-risk symptomatic aortic stenosis. The influence of gender-related differences in outcomes of patients undergoing TAVI is currently on debate.METHODS: From January 2008 to January 2015, 819 patients (49% men) underwent TAVI and were included in a multicenter Brazilian registry. Patients were followed-up and clinical outcomes were evaluated according to the updated Valve Academic Research Consortium-2 criteria. RESULTS: Mean follow-up was 497 ± 478 days. Compared with women, men had a lower rate of major or life-threatening bleeding (12.0% vs. 20.6%; HR = 0.57 [95CI% 0.40-0.81]; P = 0.001), and major vascular complications (6% vs. 11.7%; HR = 0.50 [95CI% 0.31-0.82]; P = 0.004). At 30 days, all-cause mortality was lower in men than in women (6.5% vs. 11.5%; P = 0.013), however, cumulative all-cause mortality was similar between groups (25.9% vs. 29.7%, men and women, respectively, HR = 0.92 [95CI% 0.71-1.19]; P = 0.52) over the entire follow-up period. By adjusted Cox regression model, renal function, diabetes, peripheral artery disease, and chronic obstructive pulmonary disease (COPD) remained independently predictors of all-cause mortality...


Assuntos
Estenose da Valva Aórtica , Identidade de Gênero , Pacientes
6.
Arq. bras. cardiol ; 106(6): 519-527, tab, graf
Artigo em Inglês | LILACS | ID: lil-787321

RESUMO

Abstract Background: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. Objective: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. Methods: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. Results: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. Conclusion: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.


Resumo Fundamento: O implante de válvula aórtica por cateter tornou-se uma opção para pacientes com doença valvar aórtica de elevado risco cirúrgico. Objetivo: Avaliar os resultados dos seguimentos intra-hospitalar e de até 1 ano do implante de válvula aórtica por cateter. Métodos: Estudo de coorte prospectiva de casos de implante de válvula aórtica por cateter entre julho de 2009 e fevereiro de 2015. Análise de variáveis clínicas e do procedimento, correlacionando com mortalidade intra-hospitalar e de 1 ano. Resultados: Foram submetidos ao implante 136 pacientes, com média de idade de 83 (80-87) anos, sendo 49% mulheres, 131 (96,3%) deles com estenose aórtica, um (0,7%) com insuficiência aórtica e quatro (2,9%) com disfunção de prótese. A classe funcional da NYHA foi III ou IV em 129 (94,8%) casos. A área valvar inicial foi 0,67 ± 0,17 cm2 e o gradiente ventrículo esquerdo-aorta médio de 47,3 ± 18,2 mmHg, com STS de 9,3% (4,8%-22,3%). As próteses implantadas eram autoexpansíveis em 97% dos casos. A mortalidade peroperatória em 1,5% dos casos; em 30 dias em 5,9%; intra-hospitalar em 8,1%; e após 1 ano em 15,5% dos casos. A hemotransfusão (risco relativo de 54; p = 0,0003) e a hipertensão arterial pulmonar (risco relativo de 5,3; p = 0,036) foram preditoras de mortalidade hospitalar; e a proteína C-reativa pico (risco relativo de 1,8; p = 0,013) e a hemotransfusão (risco relativo de 8,3; p = 0,0009) de mortalidade em 1 ano. Aos 30 dias, 97% dos pacientes estavam em classe NYHA I/II e, em 1 ano, o número chegou a 96%. Conclusão: O implante de válvula aórtica por cateter foi realizado com alto índice de sucesso e baixa mortalidade. A hemotransfusão associou-se com maior mortalidade hospitalar e de 1 ano. Proteína C-reativa pico se associou com a mortalidade de 1 ano.


Assuntos
Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/mortalidade , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Complicações Pós-Operatórias/mortalidade , Fatores de Tempo , Brasil/epidemiologia , Métodos Epidemiológicos
7.
Arq Bras Cardiol ; 106(6): 519-27, 2016 Jun.
Artigo em Inglês, Português | MEDLINE | ID: mdl-27192383

RESUMO

BACKGROUND: Transcatheter aortic valve implantation has become an option for high-surgical-risk patients with aortic valve disease. OBJECTIVE: To evaluate the in-hospital and one-year follow-up outcomes of transcatheter aortic valve implantation. METHODS: Prospective cohort study of transcatheter aortic valve implantation cases from July 2009 to February 2015. Analysis of clinical and procedural variables, correlating them with in-hospital and one-year mortality. RESULTS: A total of 136 patients with a mean age of 83 years (80-87) underwent heart valve implantation; of these, 49% were women, 131 (96.3%) had aortic stenosis, one (0.7%) had aortic regurgitation and four (2.9%) had prosthetic valve dysfunction. NYHA functional class was III or IV in 129 cases (94.8%). The baseline orifice area was 0.67 ± 0.17 cm2 and the mean left ventricular-aortic pressure gradient was 47.3±18.2 mmHg, with an STS score of 9.3% (4.8%-22.3%). The prostheses implanted were self-expanding in 97% of cases. Perioperative mortality was 1.5%; 30-day mortality, 5.9%; in-hospital mortality, 8.1%; and one-year mortality, 15.5%. Blood transfusion (relative risk of 54; p = 0.0003) and pulmonary arterial hypertension (relative risk of 5.3; p = 0.036) were predictive of in-hospital mortality. Peak C-reactive protein (relative risk of 1.8; p = 0.013) and blood transfusion (relative risk of 8.3; p = 0.0009) were predictive of 1-year mortality. At 30 days, 97% of patients were in NYHA functional class I/II; at one year, this figure reached 96%. CONCLUSION: Transcatheter aortic valve implantation was performed with a high success rate and low mortality. Blood transfusion was associated with higher in-hospital and one-year mortality. Peak C-reactive protein was associated with one-year mortality.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Mortalidade Hospitalar , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Insuficiência da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/epidemiologia , Brasil/epidemiologia , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Complicações Pós-Operatórias/mortalidade , Fatores de Tempo
8.
Arq Bras Cardiol ; 102(1): 93-6, 2014 Jan.
Artigo em Inglês, Português | MEDLINE | ID: mdl-24652089

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) was established as an important alternative for high-risk patients with severe aortic stenosis. However, there are few data in the literature regarding coronary obstruction, that although rare, is a potentially fatal complication. OBJECTIVE: Evaluate this complication in Brazil. METHODS: We evaluated all patients presenting coronary obstruction from the Brazilian Registry of TAVI. Main baseline and procedural characteristics, management of the complication, and clinical outcomes were collected from all patients. RESULTS: From 418 consecutive TAVI procedures, coronary obstruction occurred in 3 cases (incidence of 0.72%). All patients were women, without prior coronary artery bypass grafting (CABG), and with mean age of 85 ± 3 years, logistic EuroSCORE of 15 ± 6% and STS-PROM score of 9 ± 4%. All of the cases were performed with balloon-expandable Sapien XT prosthesis. In one patient, with pre-procedural computed tomography data, coronary arteries presented a low height and a narrow sinus of Valsalva. All patients presented with clinically significant severe maintained hypotension, immediately after valve implantation, and even though coronary angioplasty with stent implantation was successfully performed in all cases, patients died during hospitalization, being two periprocedurally. CONCLUSION: Coronary obstruction following TAVI is a rare but potentially fatal complication, being more frequent in women and with the balloon-expandable prosthesis. Anatomical factors might be related with its increased occurrence, highlighting the importance of a good pre-procedural evaluation of the patients in order to avoid this severe complication.


Assuntos
Bioprótese/efeitos adversos , Oclusão Coronária/etiologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Idoso de 80 Anos ou mais , Angioplastia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Stents Farmacológicos , Evolução Fatal , Feminino , Humanos , Complicações Pós-Operatórias , Fatores de Risco , Resultado do Tratamento
9.
Arq. bras. cardiol ; 102(1): 93-96, Jan. 2014. ilustração
Artigo em Português | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1025739

RESUMO

Fundamentos: O implante por cateter de bioprótese valvar aórtica (TAVI) consolidou-se como alternativa para o tratamento de pacientes com estenose aórtica importante de alto risco cirúrgico. Contudo, há poucos dados na literatura com respeito à obstrução coronária que, apesar de rara, trata-se de grave complicação do TAVI. Objetivo: Avaliar, no contexto brasileiro, a presença dessa importante complicação. Métodos: Foram avaliados todos os casos de obstrução coronária incluídos no Registro Brasileiro de TAVI. Foram coletados dados clínicos, do procedimento, do manejo e de evolução intra-hospitalar. Resultados: Entre 418 pacientes consecutivos do registro, ocorreram três casos de obstrução coronária (incidência de 0,72%). Em sua totalidade, os pacientes eram do sexo feminino, sem cirurgia de revascularização miocárdica (CRM) prévia, com idade média de 85 ± 3 anos, EuroSCORE logístico de 15 ± 6% e STS de 9 ± 4%. Todos os casos foram realizados com a válvula balão-expansível Sapien XT. Em um dos pacientes, com dados de tomografia computadorizada pré-procedimento, verificaram-se origem das artérias coronárias baixa e seio de Valsalva estreito. Todos os pacientes apresentaram-se clinicamente com hipotensão importante e mantida, imediatamente após o implante da válvula, e, apesar de angioplastia com implante de stent, todos os pacientes foram a óbito, sendo dois Peri procedimento e um durante hospitalização. Conclusão: A obstrução coronária como complicação do TAVI, apesar de rara, é potencialmente fatal, podendo ocorrer mais frequentemente em mulheres e com as próteses expansíveis por balão. Fatores anatômicos podem estar relacionados com sua ocorrência, ressaltando-se a importância de boa avaliação pré-procedimento no sentido de evitar essa grave complicação. (AU)


Assuntos
Estenose Coronária , Substituição da Valva Aórtica Transcateter
10.
Rev. bras. cardiol. (Impr.) ; 26(5): 400-405, set.-out. 2013. ilus, tab, graf
Artigo em Português | LILACS | ID: lil-704456

RESUMO

Relata-se o caso de paciente octogenária, com infarto agudo do miocárdio (IAM) em evolução, que desenvolveu quadro inflamatório pulmonar agudo, compatível com diagnóstico de pneumonia em organização secundária ao uso de abciximab intracoronariano, em angioplastia percutânea coronariana (APC). Esse diagnóstico foi firmado por meio de alterações clínicas, radiográficas e tomográficas típicas e pela regressão dessas alterações após terapia com corticosteroide.


This report presents the case of an octogenarian female patient with acute myocardial infarction who developed an acute inflammatory pulmonary condition compatible with a diagnosis of secondary organizing pneumonia after intracoronary abciximab during percutaneous coronary angioplasty. This diagnosis was grounded on typical clinical, radiographic and tomographic alterations and the regression of these alterations after corticoid treatment.


Assuntos
Humanos , Feminino , Idoso , Bronquiolite Obliterante/complicações , Pneumonia em Organização Criptogênica , Pneumonia em Organização Criptogênica/complicações , Stents Farmacológicos , Tomografia/métodos , Tomografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA