Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-35396197

RESUMO

OBJECTIVE: This systematic review was undertaken to determine the risk of oral cancer in patients with chronic graft-vs-host disease (cGvHD). STUDY DESIGN: The search was conducted in 6 electronic databases (PubMed/MEDLINE, EMBASE, LILACS, Web of Science, Scopus, and LIVIVO) and gray literature (Google Scholar, Open Gray, and ProQuest) for studies published up to November 2021. RESULTS: Of the 13 cohorts included in qualitative synthesis, 9 were eligible for the quantitative analysis. The meta-analysis showed that the presence of cGvHD increased the risk of developing oral cancer (risk ratio [RR] = 2.78; 95% CI, 1.27-6.08; I2 = 46%; P = .01). A subgroup meta-analysis revealed a higher risk of oral cancer in Asian samples exposed to cGvHD (RR = 2.50; 95% CI, 1.54-4.04; I2 = 0%; P = .0002), which was not seen in the pooled analysis of European samples (P = .24). The overall methodological quality of most studies included was "good." The cumulative evidence (Grading of Recommendations Assessment, Development and Evaluation) was considered moderate and of very low confidence for Asian and European studies, respectively. CONCLUSIONS: Patients with cGvHD resulting from allogenic hematopoietic stem cell transplantation run an increased risk of developing oral cancer. Hence, it is recommended that patients with cGvHD be monitored to allow for the early detection and treatment of secondary malignant disease.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Neoplasias Bucais , Doença Enxerto-Hospedeiro/complicações , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Humanos
2.
Braz Dent J ; 33(1): 22-30, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35262551

RESUMO

The aim of this study was to compare the influence of endodontic sealers artifacts on the detection of vertical root fracture in cone beam computed tomography (CBCT). Premolars and central incisors were assigned into five different groups: Control, Pulp Canal Sealer, AH Plus, Sealer 26, and BC Sealer (n= 10, per group). VRFs were mechanically induced and the teeth were inserted into an image phantom. Subsequently, CBCT (Cranex 3Dx, Soredex, Tuusula, Finland) images were obtained and two observers were asked separately to identify root fracture, by visual analysis. For both premolar and central incisors, kappa coefficients of intraobserver agreement varied from good to excellent (K: 80% - 87%), and the values for interobserver agreement varied from fair to moderate (K: 30% - 35%). As follows, the area under the curve (AUC) of receiver operating characteristic (ROC) values for VRFs highlighted that the use of BC sealer reduced the observers' ability to discriminate VRFs relative to other sealers. Moreover, sensitivity values for premolars teeth ranged from 20% to 60%, and specificity ranged from 60% to 100%; while sensitivity values for central incisors ranged from 30% to 70%, and specificity ranged from 70% to 100%. In conclusion, the low sensitivity values, mainly for premolars, demonstrated the difficulty in VRF diagnosis. Furthermore, BC Sealer induced significantly more imaging artifacts than other sealers. These results highlighting that endodontic sealers may interfere with the diagnosis of VRFs.


Assuntos
Materiais Restauradores do Canal Radicular , Fraturas dos Dentes , Artefatos , Dente Pré-Molar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem
3.
Braz. dent. j ; 33(1): 22-30, jan.-fev. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1364480

RESUMO

Abstract The aim of this study was to compare the influence of endodontic sealers artifacts on the detection of vertical root fracture in cone beam computed tomography (CBCT). Premolars and central incisors were assigned into five different groups: Control, Pulp Canal Sealer, AH Plus, Sealer 26, and BC Sealer (n= 10, per group). VRFs were mechanically induced and the teeth were inserted into an image phantom. Subsequently, CBCT (Cranex 3Dx, Soredex, Tuusula, Finland) images were obtained and two observers were asked separately to identify root fracture, by visual analysis. For both premolar and central incisors, kappa coefficients of intraobserver agreement varied from good to excellent (K: 80% - 87%), and the values for interobserver agreement varied from fair to moderate (K: 30% - 35%). As follows, the area under the curve (AUC) of receiver operating characteristic (ROC) values for VRFs highlighted that the use of BC sealer reduced the observers' ability to discriminate VRFs relative to other sealers. Moreover, sensitivity values for premolars teeth ranged from 20% to 60%, and specificity ranged from 60% to 100%; while sensitivity values for central incisors ranged from 30% to 70%, and specificity ranged from 70% to 100%. In conclusion, the low sensitivity values, mainly for premolars, demonstrated the difficulty in VRF diagnosis. Furthermore, BC Sealer induced significantly more imaging artifacts than other sealers. These results highlighting that endodontic sealers may interfere with the diagnosis of VRFs.


Resumo O objetivo deste estudo foi comparar a influência dos artefatos de cimentos endodônticos na detecção de fratura radicular vertical (FRV) em tomografia computadorizada de feixe cônico (TCFC). Pré-molares e incisivos centrais foram divididos em cinco grupos diferentes: Controle, Pulp Canal Sealer, AH Plus, Sealer 26 e BC Sealer (n = 10, por grupo). As FRVs foram induzidas mecanicamente e os dentes inseridos em uma réplica da mandibula humana. Posteriormente, imagens de TCFC (Cranex 3Dx, Soredex, Tuusula, Finlândia) foram obtidas e dois observadores foram solicitados a identificar fratura radicular separadamente, o critério utilizado foi a análise visual. Tanto para pré-molares quanto para incisivos centrais, os coeficientes kappa de concordância intraobservador variaram de bom a excelente (K: 80% - 87%), e os valores de concordância interobservador variaram de regular a moderado (K: 30% - 35%). A seguir, a área sob a curva (AUC) dos valores da característica de operação do receptor (ROC) para FRVs destacou que o uso do cimento BC Sealer reduziu a capacidade dos observadores de discriminar FRVs em relação a outros cimentos endodônticos. Além disso, os valores de sensibilidade para pré-molares variaram de 20% a 60%, e a especificidade variou de 60% a 100%; enquanto os valores de sensibilidade para incisivos centrais variaram de 30% a 70%, e a especificidade variou de 70% a 100%. Em conclusão, os baixos valores de sensibilidade, principalmente para pré-molares, demonstraram uma dificuldade no diagnóstico de FRV. Além disso, o BC Sealer induziu significativamente mais artefatos de imagem do que outros cimentos. Esses resultados evidenciam que os cimentos endodônticos podem interferir no diagnóstico das FRVs.

4.
Aust Endod J ; 48(3): 515-521, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34939718

RESUMO

Apical periodontitis shows radiographic signs such as widening of the periodontal ligament and periapical radiolucency, which differ in extent depending on the stage of the lesion. However, other lesions can be associated with or coincidental to the apical region, representing developmental lesions and benign or malignant tumours. This article describes three cases of malignant tumours, a central mucoepidermoid carcinoma (CMEC), a chondroblast osteosarcoma and an osteosarcoma of the jaw (OSJ) that presented as periapical lesions. Endodontists must be aware of unsuccessful treatment, persistent pain, signs of paraesthesia, a rapid growth rate and delayed response to therapy associated with atypical features. Complementary examinations, such as biopsy and computed tomography, can allow the early diagnosis of malignant tumours, leading to a better prognosis and thus increased survival rates and improvement in quality of life.


Assuntos
Neoplasias Ósseas , Osteossarcoma , Periodontite Periapical , Humanos , Qualidade de Vida , Diagnóstico Diferencial , Periodontite Periapical/diagnóstico por imagem , Osteossarcoma/diagnóstico , Osteossarcoma/patologia , Neoplasias Ósseas/diagnóstico
5.
Imaging Sci Dent ; 51(4): 363-372, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34987996

RESUMO

PURPOSE: This systematic review and meta-analysis assessed the diagnostic accuracy of imaging examinations for the detection of peri-implant bone defects and compared the diagnostic accuracy between titanium (Ti) and zirconium dioxide (ZrO2) implants. MATERIALS AND METHODS: Six online databases were searched, and studies were selected based on eligibility criteria. The studies included in the systematic review underwent bias and applicability assessment using the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) tool and a random-effect meta-analysis. Summary receiver operating characteristic (sROC) curves were constructed to compare the effect of methodological differences in relation to the variables of each group. RESULTS: The search strategy yielded 719 articles. Titles and abstracts were read and 61 studies were selected for full-text reading. Among them, 24 studies were included in this systematic review. Most included studies had a low risk of bias (QUADAS-2). Cone-beam computed tomography (CBCT) presented sufficient data for quantitative analysis in ZrO2 and Ti implants. The meta-analysis revealed high levels of inconsistency in the latter group. Regarding sROC curves, the area under the curve (AUC) was larger for the overall Ti group (AUC=0.79) than for the overall ZrO2 group (AUC=0.69), but without a statistically significant difference between them. In Ti implants, the AUCs for dehiscence defects (0.73) and fenestration defects (0.87) showed a statistically significant difference. CONCLUSION: The diagnostic accuracy of CBCT imaging in the assessment of peri-implant bone defects was similar between Ti and ZrO2 implants, and fenestration was more accurately diagnosed than dehiscence in Ti implants.

6.
J Prosthet Dent ; 123(6): 791-794, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31590975

RESUMO

The present technique report describes a digital workflow for flapless implant surgery after onlay block bone graft healing in the esthetic area. Virtual removal of block fixation screws and optimal single-tooth implant position and digital crown waxing were planned from cone beam computed tomography (CBCT) and intraoral scans. Two different surgical guides were digitally designed and 3D-printed to allow for flapless implant surgery. The first surgical guide was used to remove all 3 fixation screws from a healed onlay block graft, whereas the second guide was used to determine the implant position and direction. The present methodology may be considered a time-efficient flapless approach for placing implants in sites with block grafts.


Assuntos
Implantes Dentários , Cirurgia Assistida por Computador , Transplante Ósseo , Tomografia Computadorizada de Feixe Cônico , Implantação Dentária Endóssea , Estética Dentária , Impressão Tridimensional
7.
Rev. ABENO ; 19(3): 163-171, 2019. tab, ilus
Artigo em Inglês | BBO - Odontologia | ID: biblio-1050009

RESUMO

This study proposed to report a cone beam computed tomography (CBCT) teaching methodology applied to Dental School students by assessing mid-term and end-term exams correct recognition of anatomical structures. Students were instructed on oral and maxillofacial anatomical structures and clinical applications of CBCT imaging through lectures and hands-on classes, comprising forty-five hours of classes. They were submitted to two tests, the first one at mid-term and the second one at end-term. Anatomical structures recognition test scores (three variables: 1) name, 2) side ­ left/right and 3) multiplanar reconstructions (MPR) orthogonal images identification) were compared to verify if learning improvement occurred. Medians and Wilcoxon tests compared mid with end term exams. Median values for variable 1 were 6.0 (mid-term) and 8.0 (end-term). With regard to variable 2, median values ranged from 9.0 (mid-term) to 10.0 (end-term). When variable 3 results were analyzed, both mid-term and end-term medians were 10.0. Wilcoxon test (p<0.05) showed significant differences when comparing mid-term and end-term exams in each of the three categories. Linear correlations were established among the three categories. Correlations were statistically significant for two associations ("anatomical structure name" with "anatomical structure side", and "anatomical structure name" with "MPR images"). Predoctoral dental school students presented a comprehensive improvement in terms of correctly recognizing anatomical structures name and side, as well as MPR images when comparing mid-term and end-term tests (AU).


O objetivo deste estudo foi relatar uma metodologia de ensino de tomografia computadorizada de feixe cônico (TCFC) aplicada a estudantes de graduação, avaliando o conhecimento de estruturas anatômicas do complexo dentomaxilofacial. Os estudantes foram orientados quanto às estruturas anatômicas e às aplicações clínicas da TCFC em aulas teóricas e práticas, compreendendo 45 horas de aula. Foram submetidos a duas avaliações, a primeira na metade do semestre, e a segunda no término do semestre. Os escores das avaliações (três variáveis: 1) nome, 2) lado - esquerdo/direito e 3) reconstruções multiplanares (RMP) - imagens ortogonais de identificação) foram comparados para verificar se houve melhora na aprendizagem. Testes de medianas e Wilcoxon compararam os exames intermediário e final. Os valores medianos para a variável 1 foram 6,0 (intermediário) e 8,0 (final). Em relação à variável 2, a mediana variou de 9,0 (intermediário) a 10,0 (final). Quando os resultados da variável 3 foram analisados, ambas as medianas foram 10,0. Houve diferença significativa (teste de Wilcoxon, p<0,05) quando foram comparados os exames intermediário e final, nas três categorias. Correlações lineares foram estabelecidas entre as três categorias e foram estatisticamente significantes para duas associações ("nome da estrutura anatômica" com "lado da estrutura anatômica" e "nome da estrutura anatômica" com "imagens da MPR"). Os estudantes de graduação apresentaram uma melhora em termos do reconhecimento correto das estruturas anatômicas, nome e lado, bem como imagens de MPR quando comparadas as duas avaliações (AU).


Assuntos
Humanos , Masculino , Feminino , Estudantes de Odontologia , Tomografia Computadorizada por Raios X/instrumentação , Educação em Odontologia , Tomografia Computadorizada de Feixe Cônico/instrumentação , Radiologia , Estatísticas não Paramétricas , Correlação de Dados
8.
Dentomaxillofac Radiol ; 46(8): 20170400, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28749700

RESUMO

OBJECTIVES: Many studies to evaluate the accuracy of root fracture diagnosis have been conducted. However, there is a scarcity of studies to assess the quality and the sources of heterogeneity in the literature. For this reason, the aim of this study was to conduct systematic reviews and meta-analyses to summarize the available evidence on detection of root fractures by cone beam CT (CBCT) and periapical radiograph (PR) images and the interference of artefact by investigating possible sources of heterogeneity. METHODS: Studies reporting root fracture detection, from January 2010 to February 2016, were selected. All selected studies were subjected to selection criteria and then, comparative and qualitative analyses by using the quality assessment of diagnostic accuracy studies (QUADAS-2) tool were performed. Pooled sensitivity, specificity and diagnostic odds ratios were calculated. Also, receiver operator characteristics (ROC) curves were built to summarize the results. SROC curve analyses were performed to investigate the heterogeneity among studies. RESULTS: Initially, 799 articles were selected. After screening titles and abstracts, 743 articles were excluded. After reading the remaining 56 full-texts, 47 relevant articles were included in this study. Diagnostic odds ratio values revealed a wide range of results across the studies and determined a higher heterogeneity for PR compared with CBCT. The analyses of the SROC curves compared CBCT imaging versus PR in the diagnosis of root fracture, favouring CBCT modality. CONCLUSIONS: CBCT was the imaging exam that rendered a higher diagnostic accuracy for root fractures.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Radiografia Dentária Digital/métodos , Fraturas dos Dentes/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Raiz Dentária/lesões , Artefatos , Humanos , Sensibilidade e Especificidade
9.
BMC Oral Health ; 17(1): 100, 2017 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-28637451

RESUMO

BACKGROUND: Cone beam computed tomography (CBCT) has been largely used in dentistry. Nevertheless, there is lack of evidence regarding CBCT accuracy in the diagnosis of early periodontal lesions as well as the correlation between accuracy and lesion size. The aim of this study was to evaluate accuracy of CBCT and conventional intraoral radiographs in detecting different-sized interproximal bone lesions created in pig mandibles. The hypothesis was that CBCT accuracy would be superior to radiographs in detecting incipient bone lesions. METHODS: Twenty swine dry mandibles were used, totalizing 80 experimental sites. Four groups were created according to exposure time to perchloric acid 70-72%: controls (no exposure), 2-hour exposure, 4-hour exposure, and 6-hour exposure. Standardized CBCT and conventional intraoral radiographs were taken and analyzed by two trained radiologists. The presence of lesions in the dry mandible was considered the gold standard. Sensitivity, specificity, and accuracy in detecting different-sized bone lesions were calculated for CBCT and intraoral radiographs. RESULTS: Accuracy of CBCT ranged from 0.762 to 0.825 and accuracy of periapical radiography ranged from 0.700 to 0.813, according to examiner and time of acid exposure. Inter-examiner agreement varied from slight to fair, whereas intra-examiner agreement varied from moderate to substantial. CONCLUSIONS: CBCT performance was not superior to that provided by conventional intraoral radiographs in the detection of interproximal bone loss.


Assuntos
Processo Alveolar/diagnóstico por imagem , Tomografia Computadorizada de Feixe Cônico , Radiografia Dentária , Processo Alveolar/patologia , Animais , Mandíbula/diagnóstico por imagem , Doenças Periodontais/diagnóstico por imagem , Suínos
10.
Imaging Sci Dent ; 47(1): 17-24, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28361025

RESUMO

PURPOSE: The purpose of this study was to assess the accuracy, sensitivity, and specificity of the diagnosis of incipient furcation involvement with periapical radiography (PR) and 2 cone-beam computed tomography (CBCT) imaging protocols, and to test metal artifact interference. MATERIALS AND METHODS: Mandibular second molars in 10 macerated pig mandibles were divided into those that showed no furcation involvement and those with lesions in the furcation area. Exams using PR and 2 different CBCT imaging protocols were performed with and without a metallic post. Each image was analyzed twice by 2 observers who rated the absence or presence of furcation involvement according to a 5-point scale. Receiver operating characteristic (ROC) curves were used to evaluate the accuracy, sensitivity, and specificity of the observations. RESULTS: The accuracy of the CBCT imaging protocols ranged from 67.5% to 82.5% in the images obtained with a metallic post and from 72.5% to 80% in those without a metallic post. The accuracy of PR ranged from 37.5% to 55% in the images with a metallic post and from 42.5% to 62.5% in those without a metallic post. The area under the ROC curve values for the CBCT imaging protocols ranged from 0.813 to 0.802, and for PR ranged from 0.503 to 0.448. CONCLUSION: Both CBCT imaging protocols showed higher accuracy, sensitivity, and specificity than PR in the detection of incipient furcation involvement. Based on these results, CBCT may be considered a reliable tool for detecting incipient furcation involvement following a clinical periodontal exam, even in the presence of a metallic post.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA