Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Cardiol ; 25(3): 103-11, 2002 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-11890368

RESUMO

BACKGROUND: The clinical accuracy of myocardial contrast echocardiography (MCE) using intermittent harmonic imaging and intravenous perfluorocarbon containing microbubbles during dipyridamole stress has not been evaluated in a multicenter setting. HYPOTHESIS: The accuracy of dipyridamole stress contrast echo in the detection of coronary artery disease (CAD) using myocardial perfusion images is high in comparison with technetium-99 (99Tc) sestamibi single-photon emission computed tomography (MIBI SPECT) and increases the accuracy of wall motion data. METHODS: In 68 consecutive nonselected patients (46 men; mean age 66 years) from three different institutions in two countries. dipyridamole stress echo and SPECT with 99mTc MIBI were compared. Continuous intravenous (IV) infusion of perfluorocarbon exposed sonicated dextrose albumin (PESDA) (2-5 cc/min) was administered for baseline myocardial perfusion using triggered harmonic end systolic frames. Real-time digitized images were used for wall motion analysis. Dipyridamole was then injected in two steps: (1) 0.56 mg/kg for 3 min, (2) 0.28 mg/kg for 1 min, if the first step was negative for an inducible wall motion abnormality. After dipyridamole injection, myocardial contrast enhancement and wall motion were analyzed again by the same methodology. RESULTS: There were 35 patients with perfusion defects by SPECT. Wall motion was abnormal in 22, while MCE was abnormal in 32. Wall motion and MCE each had one false positive. The proportion of correctly assigned patients was significantly better with MCE than with wall motion (p = 0.03; chi square test). CONCLUSIONS: Myocardial contrast echocardiography, using intermittent harmonic imaging and intravenous perfluorocarbon containing microbubbles, is a very effective method for detecting coronary artery disease during dipyridamole stress echo.


Assuntos
Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Dipiridamol , Fluorocarbonos , Adulto , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/ultraestrutura , Ecocardiografia/métodos , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Tecnécio Tc 99m Sestamibi , Tomografia Computadorizada de Emissão de Fóton Único/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA