Bioresour Technol ; 101(10): 3452-6, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20097559

RESUMO

Winery wastewater was treated in two pilot-scale aerated lagoons operating in fed-batch mode. A first lagoon of 27.2m(3) working volume was gradually filled with wastewater with an average COD content of 8700mg/L. Given that with the flow-rate used (790L/day) this first lagoon completed its working volume after 30days of starting, part of the liquid contained in the first lagoon was transferred to another adjacent second lagoon of 10.8m(3) working volume. Therefore, the experiment continued in the second lagoon for another additional 24days using an influent with a COD content of 18,700mg/L at a flow-rate of 170L/day. After the 21st day, a maximum COD removal efficiency of 91% was achieved, and this value was maintained virtually constant until the end of the experiments. A mathematical model based on three differential equations solved simultaneously allowed the kinetic parameters of the system to be obtained.


Assuntos
Ar , Resíduos Industriais , Poluentes da Água , Vinho , Concentração de Íons de Hidrogênio , Cinética , Oxigênio , Projetos Piloto , Temperatura