Cardiovasc. revasc. med ; 29: 9-15, Aug. 2021. graf, ilus, tab
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1293172

RESUMO

BACKGROUND/PURPOSE: Local hemodynamic forces such as endothelial shear stress (ESS) may have an influence on appropriate neointimal healing, vessel remodeling, and struts absorption process following second-generation drug-eluting resorbable magnesium scaffold (RMS, Magmaris, Biotronik AG, Buelach, Switzerland) placement. The aim of this study was to investigate the impact of ESS assessed by optical coherence tomography (OCT)- based computational fluid dynamic (CFD) simulations on absorption process and coronary lumen dimension after Magmaris implantation. METHODS AND RESULTS: A total of 22 patients who were enrolled in the BIOSOLVE-II trial and underwent serial OCT assessment immediately after Magmaris implantation and at 6- and 12-month follow-up were included. We evaluated qualitative OCT findings frame by frame, and CFD simulations were performed to calculate the ESS at 3-dimensional (3D) reconstructed arteries. For quantitative calculation, the average ESS within each 1-mm section was classified into three groups: low (2.5 Pa). A significant difference of percentage remnants of scaffold was observed among the 3 groups at 12-month follow-up (P = 0.001) but not at 6-month follow-up. Low-ESS segment at baseline resulted in a greater lumen change of −1.857 ± 1.902 mm2 at 1 year compared to −1.277 ± 1.562 mm2 in the intermediate-ESS segment (P = 0.017) and − 0.709 ± 1.213 mm2 in the high-ESS segment (P = 0.001). CONCLUSION: After Magmaris implantation, the presence of higher ESS might be associated with slower strut absorption process but less luminal loss. SUMMARY FOR TABLE OF CONTENTS: The authors analyzed 22 patients from the BIOSOLVE-II trial who underwent optical coherence tomography assessment immediately after receiving a Magmaris second-generation drug-eluting resorbable magnesium scaffold. The analysis found that after Magmaris implantation, the presence of higher endothelial shear stress (ESS) might be associated with slower strut absorption process but less luminal loss. This study is the first demonstrating the impact of ESS assessed by OCT on absorption process and coronary lumen dimension after Magmaris implantation.


Assuntos
Implantes Absorvíveis , Tomografia de Coerência Óptica , Magnésio , Resistência ao Cisalhamento , Stents Farmacológicos
3.
Eur Heart J Cardiovasc Imaging ; 20(8): 916-924, Ago. 2019. tabela, gráfico, ilustração
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024905

RESUMO

AIMS : Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is an alternative novel device for treating coronary lesions. However, the relationship between in-scaffold dimensions after implantation of DREAMS 2G and vessel healing and luminal results at follow-up is unknown. The aim of this study is, therefore, to investigate whether the expansion index after implantation of DREAMS 2G as assessed by optical coherence tomography (OCT) impacts late luminal status and healing of the vessel wall. METHODS AND RESULTS : This study comprises of a total 65 out of 123 patients who were enrolled in the BIOSOLVE-II trial. We assessed both qualitative and quantitative OCT findings and the expansion index of DREAMS 2G after implantation frame by frame using OCT. Expansion index was defined as minimum scaffold area/mean reference lumen area. The over-expansion group was also defined with expansion index >1.0. The total number of analyzed frames at post-procedure and 6-month follow-up was 8243 and 8263 frames, respectively. At 6-month follow-up, in-scaffold healing was documented by the reduction of 82% in dissections, 93% in attached intra-luminal mass (ILM), 65% in non-attached ILM, and 76% in jailed side branch. The over-expansion group had significantly greater in-scaffold luminal volume loss (LVL) compared with the non-over-expansion group [over-expansion: 35.0 (18.5-52.1) mm3 vs. non-over-expansion: 21.0 (11.6-37.9) mm3, P = 0.039]. CONCLUSION : Excellent in vivo healing process after implantation of DREAMS 2G was observed at 6 months. We found that higher expansion indices were associated with higher in-scaffold LVL at 6 months assessed by OCT. (AU)


Assuntos
Vasos Coronários , Tomografia de Coerência Óptica , Stents Farmacológicos
4.
Int. j. cardiol ; 300(1): 60-65, Jul, 2019. tabela, gráfico
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1103433

RESUMO

Background The aim of this study was to compare the 12-month clinical outcomes of patients treated with Magmaris or Orsiro. Second generation drug-eluting absorbable metal scaffold Magmaris (Dreams 2G) has proved to be safe and effective in the BIOSOLVE-II study. Similarly, biodegradable polymer sirolimus-eluting stent, Orsiro has shown notable clinical results even in all-comer populations. Methods Magmaris group patients were taken from the BIOSOLVE-II and BIOSOLVE-III trials, while the patients from Orsiro group were enrolled in BIOFLOW-II trial. The primary outcome was explored using a time-to-event assessment of the unadjusted clinical outcomes for target lesion failure (TLF) at 12 months, followed by a multivariate analysis adjusting for all the significantly different covariates between the groups. Results The study population consisted of 482 patients (521 lesions), 184 patients (189 lesions) in Magmaris group and 298 patients (332 lesions) in Orsiro group. The mean age was 65.5 ±â€¯10.8 and 62.7 ±â€¯10.4 years in Magmaris and Orsiro groups, respectively ( p = 0.005). Magmaris and Orsiro unadjusted TLF rates were 6.0 and 6.4% with no significant difference between the groups ( p = 0.869). In the multivariate analysis, there were no meaningful differences between Magmaris and Orsiro groups. Finally, none of the groups presented device thrombosis cases at 12 months. Conclusion At 12 months there were no significant differences between Magmaris and Orsiro groups neither in the unadjusted assessment nor in the multivariate analysis for target lesion failure. These results should be taken as hypothesis generating and may warrant a head to head comparison on a randomized fashion.


Assuntos
Análise Multivariada , Stents Farmacológicos , Sirolimo
5.
Cardiovasc Revasc Med ; 20(5): 392-398, May 2019. ilus, tab
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1006900

RESUMO

Introduction and objective: The edge vascular response (EVR) remains unknown in second generation drugeluting Resorbable Magnesium Scaffold (RMS), such as Magmaris. The aim of the study was to evaluate tissue modifications in the RMS edges over time, assessed by different invasive imaging modalities. Methods: The patients treated with the device were assessed by optical coherence tomography (OCT), grayscale intravascular ultrasound (IVUS), and virtual histology IVUS at baseline and 12 months. The EVR study performed a segment- and frame-level analysis of the 5 mm segments proximal and distal of the actual RMS. Results: The segment-level grayscale IVUS (n=10), virtual histology IVUS (n=10), and OCT (n=18) analysis did not showany significant changes after 12months, except for a fibrous plaque area (FPA) reduction of 0.5mm2 (p=0.017) in the proximal segment compared to baseline. In the frame-level analysis, IVUS evaluation revealed a vessel area decreased 2.80 ± 1.43 mm2 (p = 0.012) and 2.49 ± 1.53 mm2 (p = 0.022) in 2 proximal frames. This was accompanied by plaque area reduction of 0.88 ± 0.70 mm2 (p = 0.048) and a FPA decreased by 0.63 ± 0.48mm2 (p = 0.004) in one proximal frame. In 1 distal frame, there was a dense calcium area reduction of 0.10 ± 0.12 mm2 (p = 0.045), FPA and fibrous fatty plaque increased 0.54 ± 0.53 mm2 (p = 0.023) and 0.17 ± 0.16 mm2 (p = 0.016), respectively. By OCT, there was a lumen area decrease of 0.76 ± 1.51 mm2 (p = 0.045) in a distal frame. Conclusion: At 12 months, Magmaris EVR assessment does not show overall significant changes, except for a fibrous plaque area reduction in the proximal segment. This could be translated as a benign healing process a the edges of the RMS. Summary: The edge vascular response (EVR) remains unknown in second generation drug-eluting absorbable metal scaffolds (RMS), such as Magmaris. Patients treated with the device were assessed by multi invasive imagingmodalities [i.e. optical coherence tomography (OCT), grayscale intravascular ultrasound (IVUS), and virtual histology IVUS] evaluating the tissue changes over timein the segment- and frame-level analysis of the 5mm segments proximal and distal of the actual RMS. As a result, after 12months, Magmaris EVR assessment does not show overall significant changes, except for a fibrous plaque area reduction in the proximal segment, translating a benign healing process at the edges of the RMS.


Assuntos
Humanos , Ultrassonografia de Intervenção , Tomografia de Coerência Óptica
6.
Am. j. cardiol ; 123(7): 1044-1051, Apr. 2019. tab, ilus, graf
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1022205

RESUMO

Second-generation drug-eluting absorbable metal scaffold (DREAMS 2G) is used for treating coronary lesions. However, the natural history of the jailed side-branch (SB) after DREAMS 2G implantation remains to be elucidated. The aim of this study is to investigate the effect of scaffold struts on jailed SBs as assessed by 3-dimensional (3D) optical coherence tomography (OCT) after implantation of DREAMS 2G. We enrolled the patients who received a DREAMS 2G implantation and where OCT was performed at postprocedure and 12-month follow-up in the BIOSOLVE-II trial. The area of the ostium of jailed SBs and number of compartments divided by scaffold struts were assessed by cut-plane analysis using 3D OCT. A total of 24 patients with 61 jailed SBs were analyzed in this study. The number of compartments was significantly decreased (postprocedure; 1.98 +/- 0.84 vs 12 months; 1.10 +/- 0.30, p <0.001) during the 12 months. Since most of the struts disappeared, the ostium area was increased in 62% of jailed SBs at 12 months, however, not significantly different from postprocedure (postprocedure; 0.74 [0.34 to 1.46] mm(2) vs 12 months; 0.78 [0.41 to 1.68] mm(2), p=0.055). The number of compartments created by scaffold struts and branching angle at postprocedure had no effect on the changes of SB ostium área. DREAMS 2G has a favorable absorption process in the jailed SBs up to 12 months and may be considered as an optional therapy for treating lesions that involve SBs. (AU)


Assuntos
Humanos , Doença da Artéria Coronariana , Tomografia de Coerência Óptica , Stents Farmacológicos
7.
Open Heart ; 6(1): 1-9, Fev. 2019. ilustração, tabela, gráfico
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1024948

RESUMO

OBJECTIVES: We aimed to evaluate the mechanical properties and healing patterns 6 and 9 months after implantation of the sirolimus-eluting Phantom bioresorbable scaffold (BRS). BACKGROUND: The Phantom BRS (Reva Medical, San Diego, USA) has differentiating properties including radiopacity, strut thickness of 125 µm, high expansion capacity and has demonstrated favorable mid-term clinical and angiographic outcomes. METHODS AND RESULTS: FANTOM II was a prospective, single arm study with implantation of the Phantom BRS in 240 patients with stable angina pectoris. Guidance by optical coherence tomography (OCT) was encouraged and was repeated at 6-month (cohort A) or 9-month follow-up (cohort B). Matched baseline and follow-up OCT recordings were available in 152 patients. In-scaffold mean lumen area in cohort A was 6.8±1.7 mm2 and 5.7±1.4 mm2 at baseline and follow-up (p<0.0001) and was 7.2±1.6 mm2 and 5.6±1.4 mm2 in cohort B (p<0.0001). Mean scaffold area remained stable from 7.1±1.5 mm2 at baseline to 7.2±1.4 mm2 at 6 months (p=0.12), and from 7.4±1.5 mm2 to 7.3±1.4 mm2 at 9 months. Strut malposition was median 0.8 (IQR 0.0;3.5)% and 1.8 (IQR 0.3;6.0)% at baseline and was 0.0 (IQR 0.0;0.0)% in both groups at 6-month and 9-month follow-up. Strut tissue coverage was 98.1 (IQR 95.9;99.4)% at 6 months and 98.9 (IQR 98.3;100.0)% at 9 months. CONCLUSIONS: The novel Phantom BRS had favorable healing patterns at 6-month and 9-month follow-up as malposition was effectively resolved and strut coverage was almost complete. The scaffold remained stable through follow-up with no signs of systematic late recoil. (AU)


Assuntos
Doença da Artéria Coronariana , Tomografia de Coerência Óptica , Stents Farmacológicos
8.
Catheter. cardiovasc. interv ; 92(7): 502, : 511, Dec. 2018. graf, tab, ilus
Artigo em Inglês | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1247595

RESUMO

OBJECTIVES: Based on outcomes of the BIOSOLVE-II study, a novel second generation drug eluting absorbable metal scaffold gained CE-mark in 2016. The BIOSOLVE-III study aimed to confirm these outcomes and to obtain additional 12-month angiographic data. BACKGROUND: Bioresorbable scaffolds are intended to overcome possible long-term effects of permanent stents such as chronic vessel wall inflammation, stent crushing, and fractures. METHODS: The prospective, multicenter BIOSOLVE-II and BIOSOLVE-III studies enrolled 184 patients with 189 lesions (123 patients in BIOSOLVE-II and 61 patients in BIOSOLVE-III). Primary endpoints were in-segment late lumen loss at 6 months (BIOSOLVE-II) and procedural success (BIOSOLVE-III). RESULTS: Mean patient age was 65.5 6 10.8 years and mean lesion reference diameter was 2.70 6 0.43 mm. In BIOSOLVE-III, there were significantly more type B2/C lesions than in BIOSOLVE-II (80.3% versus 43.4%, P < 0.0001) and significantly more moderate-to-severe calcifications (24.2% versus 10.7%, P 5 0.014). At 12 months, there was no difference in late lumen loss between the two studies; in the overall population, it was 0.25 6 0.31 mm in-segment and 0.396 0.34 mm in scaffold. Target lesion failure occurred in six patients (3.3%) and included two cardiac deaths, one target-vessel myocardial infarction, and three clinically driven target lesion revascularizations. No definite or probable scaffold thrombosis was observed. CONCLUSION: The pooled outcomes of BIOSOLVE-II and BIOSOLVE-III provide further evidence on the safety and performance of a novel drug-eluting absorbable metal scaffold with constant clinical and angiographic performance parameters at 12 months and no definite or probable scaffold thrombosis.


Assuntos
Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Intervenção Coronária Percutânea , Implantes Absorvíveis , Stents Farmacológicos
9.
Int J Cardiol ; 255(mar): 22-28, 2018. tab, graf, ilus
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1063465

RESUMO

RATIONALE: Bioresorbable scaffolds may confer clinical benefit in long-term studies; early mechanistic studies using intravascular imaging have provided insightful information about the immediate and mid-term local serial effects of BRS on the coronary vessel wall. OBJECTIVES: We assessed baseline, 6- and 12-month imaging data of the drug-eluting absorbable metal scaffold (DREAMS 2G). METHODS AND RESULTS: The international, first-in-man BIOSOLVE-II trial enrolled 123 patients with up to 2 de novo lesions (in vessels of 2.2 to 3.7mm). Angiographic based vasomotion, curvature and angulation were assessed; intravascular ultrasound (IVUS) derived radiofrequency (RF) data analysis and echogenicity were evaluated; optical coherence tomography (OCT) attenuation and backscattering analysis were also performed. There was hardly any difference in curvature between pre-procedure and 12months (-0.0019; p=0.48). The change in angulation from pre- to 12months was negligible (-3.58°; 95% CI [-5.97, -1.20]), but statistically significant. At 6months, the change in QCA based minimum lumen diameter in response to high dose of acetylcholine and IVUS-RF necrotic core percentage showed an inverse relationship (estimate of -0.489; p=0.055) and with fibrous volume a positive relationship (estimate of 0.53, p=0.035). Bioresorption analysis by OCT showed that the maximum attenuation values decreased significantly from post-procedure at 6months (Δ 6months vs. post-proc. is -13.5 [95% CI -14.6, -12.4]) and at 12months (Δ 12months vs. post-proc. is -14.0 [95% CI -15.4, -12.6]). By radiofrequency data, the percentage of dense calcium decreased significantly from post-procedure at 6months and at 12months...


Assuntos
Doença da Artéria Coronariana , Sirolimo , Stents Farmacológicos
10.
EuroIntervention ; 13(4): 432-439, 2017.
Artigo em Inglês | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1062707

RESUMO

AIMS: We aimed to assess the safety and performance of the DREAMS 2G scaffold up to 24 months post implant. METHODS AND RESULTS: The present study population comprises a total of 184 patients with 189 lesions who were enrolled in the prospective, multicentre BIOSOLVE-II and BIOSOLVE-III trials. Clinical follow-up was scheduled at one, six, 12, 24 and 36 months. The present report includes pooled follow-up data at six months and BIOSOLVE-II data at 24 months. Patients were 65.5±10.8 years old, and lesions were 12.5±5.1 mm long with reference diameters of 2.7±0.4 mm. Procedural success was obtained in 97.8%. At six months, the composite clinical endpoint target lesion failure was 3.3% (95% CI: 1.2-7.1), based on two cardiac deaths (1.1%, one unknown and one not device-related), one target vessel myocardial infarction (0.6%), and three clinically driven target lesion revascularisations (1.7%). For BIOSOLVE-II at 24 months, the target lesion failure rate was 5.9% (95% CI: 2.4-11.8), based on two cardiac deaths (1.7%), one target vessel myocardial infarction (0.9%) and four target lesion revascularisations (3.4%). There was no definite or probable scaffold thrombosis...


Assuntos
Coração , Doenças Cardiovasculares , Estudos de Casos e Controles , Stents Farmacológicos