Your browser doesn't support javascript.
loading
Mostrar:20 |50 |100
Resultados 1 -20 de 49
Filtrar
Mais filtros













Base de dados
Intervalo de ano de publicação
1.
Case Rep Infect Dis ;2024: 1937661, 2024.
ArtigoemInglês |MEDLINE | ID: mdl-38715575

RESUMO

Introduction: Herpes simplex (HSV) and varicella zoster (VZV) viruses are harmful infectious agents in pregnancy due to their ability to impact maternal-fetal dyads through various modalities including vertical transmission, neonatal infection, and maternal morbidity. As a result, accurate diagnosis and prompt treatment of these infections in pregnancy is critical. Case: A 19-year-old primigravida presented to our tertiary care center at 30 weeks' gestation with vulvar swelling, burning, and pain. Workup included direct PCR testing of a particularly erythematous area of the vulva which returned positive for VZV. The patient was treated with a 10-day course of acyclovir with resolution of her symptoms. She later had a full-term spontaneous vaginal delivery outside of the infectious window with no significant morbidity for either her or her neonate. Conclusion: Although a rare presentation, the presence of a genital lesion or labial swelling during pregnancy warrants workup for VZV, particularly among patients known to be varicella nonimmune. If genital VZV is diagnosed during pregnancy, the development of contingency plans through interdisciplinary collaboration should be pursued to ensure a safe delivery and postpartum course for both the maternal-fetal dyad as well as other patients on the unit and the provider care team.

3.
Clin Biochem ;125: 110731, 2024 Mar.
ArtigoemInglês |MEDLINE | ID: mdl-38360198

RESUMO

BACKGROUND: An analytical benchmark for high-sensitivity cardiac troponin (hs-cTn) assays is to achieve a coefficient of variation (CV) of ≤ 10.0 % at the 99th percentile upper reference limit (URL) used for the diagnosis of myocardial infarction. Few prospective multicenter studies have evaluated assay imprecision and none have determined precision at the female URL which is lower than the male URL for all cardiac troponin assays. METHODS: Human serum and plasma matrix samples were constructed to yield hs-cTn concentrations near the female URLs for the Abbott, Beckman, Roche, and Siemens hs-cTn assays. These materials were sent (on dry ice) to 35 Canadian hospital laboratories (n = 64 instruments evaluated) participating in a larger clinical trial, with instructions for storage, handling, and monthly testing over one year. The mean concentration, standard deviation, and CV for each instrument type and an overall pooled CV for each manufacturer were calculated. RESULTS: The CVs for all individual instruments and overall were ≤ 10.0 % for two manufacturers (Abbott CVpooled = 6.3 % and Beckman CVpooled = 7.0 %). One of four Siemens Atellica instruments yielded a CV > 10.0 % (CVpooled = 7.7 %), whereas 15 of 41 Roche instruments yielded CVs > 10.0 % at the female URL of 9 ng/L used worldwide (6 cobas e411, 1 cobas e601, 4 cobas e602, and 4 cobas e801) (CVpooled = 11.7 %). Four Roche instruments also yielded CVs > 10.0 % near the female URL of 14 ng/L used in the United States (CVpooled = 8.5 %). CONCLUSIONS: The number of instruments achieving a CV ≤ 10.0 % at the female 99th-percentile URL varies by manufacturer and by instrument. Monitoring assay precision at the female URL is necessary for some assays to ensure optimal use of this threshold in clinical practice.


Assuntos
Infarto do Miocárdio, Humanos, Masculino, Feminino, Estudos Prospectivos, Canadá, Infarto do Miocárdio/diagnóstico, Bioensaio, Troponina, Troponina T, Biomarcadores, Valores de Referência
7.
J Clin Med ;10(5)2021 Mar 02.
ArtigoemInglês |MEDLINE | ID: mdl-33801415

RESUMO

High-sensitivity cardiac troponin (hs-cTn) testing has enabled physicians to make earlier diagnostic and prognostic decisions in the hospital setting than previous cardiac troponin assays. Analytical improvements have permitted one to measure cardiac troponin precisely in the nanogram per litre (ng/L) range with hs-cTn assays which has resulted in fast 0/1-h and 0/2-h algorithms for ruling-in and ruling-out myocardial infarction. Although analytical interferences that affect the reporting of hs-cTn are uncommon, not all hs-cTn assays are designed the same nor have undergone the same clinical and analytical validations. Here, after investigating an initial case of discrepant hs-cTnI results, we report that patients with an acute phase response (e.g., patients with inflammatory or infectious illnesses) can yield high and non-reproducible results with the Ortho Clinical Diagnostics hs-cTnI assay. Compared to Abbott Diagnostics hs-cTnI, Ortho Clinical Diagnostics hs-cTnI assay misclassifies biochemical injury in approximately 10% of the population being assessed for myocardial injury with imprecise results in approximately half of this population (i.e., 5%). In conclusion, caution is warranted in interpreting Ortho Clinical Diagnostics hs-cTnI alone in patients being evaluated for myocardial injury, especially in patients whose primary presentation is related to an acute phase response and not an acute coronary syndrome symptom.

8.
J Cardiovasc Dev Dis ;8(3)2021 Mar 23.
ArtigoemInglês |MEDLINE | ID: mdl-33806960

RESUMO

Differences in patient classification of myocardial injury between high-sensitivity cardiac troponin (hs-cTn) assays have largely been attributed to assay design and analytical sensitivity aspects. Our objective was to compare Ortho Clinical Diagnostics' (OCD) hs-cTnI assay to OCD's contemporary/conventional assay (cTnI ES) and another hs-cTnI assay (Abbott hs-cTnI) in samples obtained from different emergency departments (EDs). Two different sample types were evaluated (lithium heparin and ethylenediaminetetraacetic acid (EDTA) plasma) in a non-selected ED population (study 1, n = 469 samples) and in patients for which ED physicians ordered cardiac troponin testing (study 2, n = 1147 samples), from five different EDs. The incidence of injury in study 1 was higher with the OCD hs-cTnI assay (30.9%; 95% CI: 26.9 to 35.2) compared to that of the Abbott hs-cTnI (17.3%; 95% CI: 14.1 to 21.0) and the OCD cTnI ES (15.4%; 95% CI: 12.4 to 18.9) assays, with repeat testing identifying 4.8% (95% CI: 3.0 to 7.5) of the OCD hs-cTnI results with poor reproducibility. In study 2, 4.6% (95% CI: 3.5 to 6.0) of the results were not reported for the OCD hs-cTnI assay (i.e., poor reproducibility) with 12.7% (95%CI: 8.7 to 17.8) of the OCD hs-cTnI results positive for injury being negative for injury with the Abbott hs-cTnI assay. In summary, the OCD hs-cTnI assay yields higher rates of biochemical injury with a higher rate of poor reproducible results in different ED populations.

9.
Clin Chem Lab Med ;59(4): 749-755, 2021 03 26.
ArtigoemInglês |MEDLINE | ID: mdl-33079697

RESUMO

OBJECTIVES: To analytically evaluate Ortho Clinical Diagnostics VITROS high-sensitivity cardiac troponin I (hs-cTnI) assay in specific matrices with comparison to other hs-cTn assays. METHODS: The limit of detection (LoD), imprecision, interference and stability testing for both serum and lithium heparin (Li-Hep) plasma for the VITROS hs-cTnI assay was determined. We performed Passing-Bablok regression analyses between sample types for the VITROS hs-cTnI assay and compared them to the Abbott ARCHITECT, Beckman Access and the Siemens ADVIA Centaur hs-cTnI assays. We also performed Receiver-operating characteristic curve analyses with the area under the curve (AUC) determined in an emergency department (ED)-study population (n=131) for myocardial infarction (MI). RESULTS: The VITROS hs-cTnI LoD was 0.73 ng/L (serum) and 1.4 ng/L (Li-Hep). Stability up to five freeze-thaws was observed for the Ortho hs-cTnI assay, with the analyte stability at room temperature in serum superior to Li-Hep with gross hemolysis also affecting Li-Hep plasma hs-cTnI results. Comparison of Li-Hep to serum concentrations (n=202), yielded proportionally lower concentrations in plasma with the VITROS hs-cTnI assay (slope=0.85; 95% confidence interval [CI]:0.83-0.88). In serum, the VITROS hs-cTnI concentrations were proportionally lower compared to other hs-cTnI assays, with similar slopes observed between assays in samples frozen <-70 °C for 17 years (ED-study) or in 2020. In the ED-study, the VITROS hs-cTnI assay had an AUC of 0.974 (95%CI:0.929-0.994) for MI, similar to the AUCs of other hs-cTn assays. CONCLUSIONS: Lack of standardization of hs-cTnI assays across manufacturers is evident. The VITROS hs-cTnI assay yields lower concentrations compared to other hs-cTnI assays. Important differences exist between Li-Hep plasma and serum, with evidence of stability and excellent clinical performance comparable to other hs-cTn assays.


Assuntos
Bioensaio, Infarto do Miocárdio, Troponina I, Heparina, Humanos, Limite de Detecção, Infarto do Miocárdio/diagnóstico, Curva ROC
17.
Clin Biochem ;69: 52-56, 2019 Jul.
ArtigoemInglês |MEDLINE | ID: mdl-31063741

RESUMO

BACKGROUND: Siemens Healthcare Diagnostics has four commercially available assays on different analytical platforms using different methodologies to generate signal. We assessed the analytical performance of the Dimension EXL hs-cTnI assay (LOCI method) across different matrices and compared it to two different acridinium ester-based hs-cTnI assays (ADVIA Centaur and Abbott ARCHITECT). METHODS: The analytical sensitivity and precision below the 99th-percentile was determined for the Dimension EXL hs-cTnI assay. Method comparisons were performed between the Dimension EXL contemporary cTnI and the hs-cTnI assays, between different matrices for the EXL hs-cTnI assay (serum, lithium heparin and EDTA plasma), and between different hs-cTnI assays (EXL versus ADVIA Centaur or Abbott ARCHITECT) using non-parametric analyses. RESULTS: The limit of blank and detection were 0.9 ng/L and 1.7 ng/L, respectively, with imprecision of 5.8% at 8.6 ng/L and 3.2% at 47.5 ng/L. Comparison between the EXL contemporary cTnI and hs-cTnI assay (range: 2.6-4214 ng/L) yielded proportional lower concentrations for the hs-cTnI assay (slope = 0.86; 95%CI: 0.81 to 0.96, n = 40); however, there was no difference in concentrations below 100 ng/L between the assays (median difference = -2.7 ng/L; 95%CI: -9.8 to 9.3). Passing-Bablok regression analysis with EDTA plasma yielded proportionally higher concentrations with the EXL hs-cTnI versus Abbott hs-cTnI (slope = 1.45; 95%CI: 1.02-1.86, n = 40) with proportionally lower concentrations with EDTA versus lithium heparin plasma with the EXL hs-cTnI assay alone (slope = 0.93; 95%CI: 0.90 to 0.99, n = 40). Comparison with Abbott hs-cTnI concentrations below 100 ng/L in the three matrices, indicated that the EXL hs-cTnI assay yielded higher concentrations (median difference range: 3.4-9.4 ng/L), with differences also evident when comparing the EXL hs-cTnI assay to the ADVIA Centaur hs-cTnI assay. CONCLUSION: The Siemens EXL hs-cTnI assay meets the analytical criteria for a high-sensitivity assay, with assay specific cutoffs important to maximize clinical performance.


Assuntos
Troponina I/sangue, Testes Diagnósticos de Rotina, Feminino, Humanos, Limite de Detecção, Masculino, Pessoa de Meia-Idade
18.
Clin Chem Lab Med ;57(5): 745-751, 2019 04 24.
ArtigoemInglês |MEDLINE | ID: mdl-30838842

RESUMO

Background Manufacturers of high-sensitivity cardiac troponin (hs-cTn) assays have restricted use of what sample types or matrices are acceptable to use for measurement. Our goal was to evaluate the comparability of the Siemens ADVIA Centaur hs-cTnI assay across different matrices and under different storage conditions. Methods Three different QC-plasma matrices were evaluated for imprecision <10 ng/L. Passing-Bablok regression and difference plots were determined for cTnI concentrations spanning the reference interval (limit of quantification to male 99th-percentile: 2.5 ng/L to <60 ng/L) between serum and lithium heparin plasma, lithium heparin and EDTA plasma and between the Siemens and Abbott hs-cTnI assays. Stability at room temperature (RT) and 2-8 °C was also assessed across the three matrices. Results Over 16-weeks the SDs were ≤1.0 ng/L for QCs ranging from 5.0 to 8.3 ng/L. Across the reference interval there was excellent agreement between lithium heparin plasma and serum for the Siemens hs-cTnI assay (slope=0.98/intercept=-0.1), however, cTnI concentrations were proportionally lower in EDTA as compared to lithium heparin plasma (slope=0.90, 95% CI: 0.88-0.92). In lithium heparin plasma the Siemens hs-cTnI concentrations were higher than the Abbott hs-cTnI concentrations (slope=1.26/intercept=-0.2). Stability of cTnI in lithium heparin plasma as compared in serum and EDTA plasma appeared more labile, with decreases ≥20% in concentrations evident as early as 1-day in storage at RT. Conclusions There is excellent agreement in concentrations between lithium heparin plasma and serum with the Siemens ADVIA Centaur hs-cTnI assay; however, cTnI concentrations in EDTA plasma are lower. Reference intervals and clinical studies in EDTA plasma for the Centaur hs-cTnI assay are required before clinical use.


Assuntos
Troponina I/sangue, Análise Química do Sangue/normas, Coleta de Amostras Sanguíneas, Ácido Edético/química, Heparina/química, Humanos, Imunoensaio/normas, Controle de Qualidade, Valores de Referência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...