Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J. oral res. (Impresa) ; 13(1): 160-169, mayo 29, 2024. ilus
Artigo em Inglês | LILACS | ID: biblio-1563437

RESUMO

Objective: To evaluate the influence of opacity and the layering technique on the fluorescence of different composite resins. Materials and Methods: Two opacities (enamel and dentin) and the layering technique (enamel + dentin) of the composite resins: Filtek® Z350 and Palfique LX5 were evaluated in vitro. Composite resin discs were fabricated using a preformed matrix of 10 mm diameter and 0.5 mm thick for the single opacity groups and 10 mm thick for the layering technique groups, using 2 layers of 0.5 mm thickness of each opacity (n = 5). Specimens were analyzed using the Raman spectroscopy method. Data were analyzed using the Kruskall-wallis and Mann-Whitney U tests. Results: When evaluating the intensity of fluorescence, no statistically significant difference was found when comparing the layering technique and enamel opacity (p2> 0.05) and an increase in the dentin opacity value for both brands of composite resin. Regarding wavelength, no statistically significant difference was found when comparing the layering technique with enamel opacity and dentin opacity for both Filtek® Z350 and Palfique LX5® composite resins (p2 > 0.05). Conclusions: The fluorescence intensity of the layering technique is similar to enamel opacity for both composite resins. Likewise, the wavelength of the layering technique is similar to the enamel opacity and dentin opacity for both brands.


Objetive: Evaluar la influencia de la opacidad y de la técnica de estratificación en la fluorescencia de diferentes resinas compuestas. Materiales y Métodos: Se evaluó in vitro 2 opacidades (Esmalte y Dentina) y la técnica de estratificación (Esmalte + Dentina) de las resinas compuestas: Filtek® Z350 y Palfique LX5. Se fabricaron discos de resina compuesta, utilizando una matriz preformada de 10 mm de diámetro y 0,5 mm de grosor para los grupos de opacidad única y 10 mm de grosor para los grupos de técnica estratificada, utilizando 2 capas de 0,5 mm de cada opacidad (n = 5). Los especímenes se analizaron mediante el método de Espectroscopía Raman. Los datos se analizaron utilizando la prueba de Kruskall-wallis y Prueba U de Mann Whitney. Resultado: Al evaluar la intensidad de fluorescencia no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte para ambas marcas de resina compuesta Filtek® Z350 y para Palfique LX5® (p2 > 0,05). Para longitud de onda no se encontró diferencia estadísticamente significativa entre los pares: Técnica estratificada versus Opacidad Esmalte y Técnica estratificada VS Opacidad Dentina para ambas resinas compuesta Filtek® Z350 y Palfique LX5® (p2> 0,05). Conclusión: La intensidad de fluorescencia de la técnica estratificada es similar a la opacidad Esmalte para ambas resinas compuestas. De igual manera la longitud de onda de la técnica estratificada es similar a la opacidad Esmalte y opacidad Dentina para ambas marcas.


Assuntos
Humanos , Resinas Compostas/química , Nanotecnologia/métodos , Análise Espectral , Técnicas In Vitro
2.
Rev. cuba. estomatol ; 60(4)dic. 2023.
Artigo em Espanhol | LILACS, CUMED | ID: biblio-1550856

RESUMO

Objetivo: Comparar el efecto de antibióticos pediátricos sobre la microdureza superficial del esmalte dental en dientes bovinos. Métodos: Se realizó un estudio in vitro en 60 dientes bovinos no cariados. Se sumergieron 15 dientes en cada grupo de cuatro soluciones (amoxicilina, amoxicilina + ácido clavulánico, eritromicina y saliva artificial) durante 1 minuto tres veces al día durante 7 y 14 días. Se midió la microdureza de la superficie del esmalte al inicio, a los7 y 14 días de exposición a los antibióticos. Resultados: La microdureza superficial del esmalte de los dientes de los grupos de antibióticos pediátricos se redujo después de 7 y 14 días de exposición con diferencia significativa (p < 0,001), respecto a la microdureza inicial. Además, en el grupo expuesto a saliva artificial no hubo diferencia significativa (p = 0,097) en los diferentes tiempos de evaluación. Conclusiones: Se concluye que los antibióticos pediátricos afectan la microdureza del esmalte, siendo la eritromicina la que mayor disminución generó a los 14 días de exposición(AU)


Objective: To compare the effect of pediatric antibiotics on the superficial microhardness of dental enamel in bovine teeth. Methods: An in vitro study was carried out on 60 non carious bovine teeth. Fifteen teeth were immersed in each group of four solutions (amoxicillin, amoxicillin + clavulanic acid, erythromycin and artificial saliva) for 1 minute three times a day for 7 and 14 days. Enamel surface microhardness was measured at baseline, 7 and 14 days of antibiotic exposure. Results: The enamel surface microhardness of the teeth of the pediatric antibiotic groups was reduced after seven and 14 days of exposure with significant difference (p < 0.001), with respect to the initial microhardness. In addition, in the group exposed to artificial saliva there was no significant difference (p = 0.097) at the different evaluation times. Conclusions: It is concluded that pediatric antibiotics affect enamel microhardness and erythromycin generated the greatest decrease at 14 days of exposure(AU)


Assuntos
Humanos , Criança , Amoxicilina/uso terapêutico , Antibacterianos/administração & dosagem
3.
Odovtos (En línea) ; 22(2)ago. 2020.
Artigo em Espanhol | LILACS, SaludCR | ID: biblio-1386467

RESUMO

Resumen: Objetivo: El propósito de este estudio fue evaluar la influencia de los niveles de pH de tres geles de blanqueamiento de consultorio en la rugosidad superficial del esmalte bovino, después del protocolo del blanqueamiento. Materiales y métodos: Se obtuvo 36 muestras de esmalte bovino, las cuales fueron cortadas y divididas en tres grupos (n=15): peróxido de hidrógeno 40% (Opalescence Boost 40%), peróxido de hidrógeno 35% (Whiteness HP AutoMixx) y peróxido de hidrógeno 35% (Whiteness HP Blue), recibiendo una aplicación de 40 minutos de blanqueamiento. Los valores del promedio del pH fueron determinados utilizando un pHmetro durante la aplicación inicial y final del gel. Un rugosímetro fue utilizado para evaluar la rugosidad superficial (Ra) antes y después del blanqueamiento. Los datos fueron analizados con la prueba de Friedmann y wilcoxon (diferencia entre grupos); la prueba Kruskall Wallis y U de mann (diferencia en cada grupo), así como prueba de Pearson o Spearman para la correlación. Resultados: Hay un aumento en los valores del pH del inicio al final del blanqueamiento en todos los grupos, excepto para el grupo peróxido de hidrógeno 35% (Whiteness HP Automixx). Para los resultados de rugosidad superficial existe un aumento en todos los grupos. No se encontró correlación entre niveles de pH de los geles blanqueadores y la rugosidad superficial del esmalte después del blanqueamiento. Conclusiones: Los geles blanqueadores de peróxido de hidrógeno con altas concentraciones que presenten un pH alto o bajo podrían causar alteraciones de la superficie del esmalte dental, como el aumento en la rugosidad superficial.


Abstract: Objective: The purpose of this study was to evaluate the influence of the pH levels of three in-office bleaching gels on the surface roughness of bovine enamel, after the bleaching protocol. Materials and methods: 36 samples of bovine enamel were obtained, which were cut and divided into three groups (n=12): 40%hydrogen peroxide (Opalescence Boost40%), 35% hydrogen peroxide (Whiteness HP AutoMixx) and 35% hydrogen peroxide (Whiteness HP Blue), receiving a 40-minute application of bleaching. The average pH values were determined using a pH meter during the initial and final application of the gel. A roughness meter was used to assess surface roughness (Ra) before and after bleaching. Data were analyzed with the Friedmann and wilcoxon test (difference between groups); the Kruskall Wallis and U Mann test (difference in each group), as well as Pearson or Spearman test for correlation. Results: There is an increase in pH values from the beginning to the end of bleaching in all groups, except for the 35% hydrogen peroxide group (Whiteness HP Automixx). For surface roughness results there is an increase in all groups. No correlation was found between pH values of the bleaching gels and the surface roughness of the enamel after bleaching. Conclusions: Hydrogen peroxide bleaching gels with high concentrations that have a high or low pH could cause alterations in the surface of the tooth enamel, such as increase in surface roughness.


Assuntos
Clareadores Dentários , Concentração de Íons de Hidrogênio
4.
Rev. dental press estét ; 9(3): 32-36, Jul-Dec.2012.
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-857631

RESUMO

(Por Alberth D. Correa-Medina) Essa questão é complexa para responder, pois alguns pontos ainda estão em discussão, tais como: a) as razões que indicam o uso de clorexidina; b) se utilizada, em que momento do procedimento adesivo é melhor, antes ou depois do condicionamento ácido?; e c) pode ser utilizada com sistemas adesivos convencionais e autocondicionantes? A clorexidina, em concentrações menores que 1%, tem ação bacteriostática, provocando danos na membrana e perda de substâncias de baixo peso molecular, tais como potássio e íons de flúor, embora não produza a morte bacteriana. Entretanto, em concentrações superiores a 1% causa coagulação e precipitação do citoplasma, produzindo morte celular, sendo altamente bactericida. Essa substância age sobre gram-positivos e negativos aeróbios e anaeróbios. Tem várias aplicações e, na área da Odontologia Restauradora, tem sido indicada para a limpeza de cavidades antes que sejam restauradas, porque proporciona desinfecção adequada dos tecidos dentários. Em lesões cariosas em que toda estrutura infectada tenha sido removida, indicava-se aplicar essa solução como uma forma de assegurar a remoção completa de restos de organismos que poderiam ficar presentes na cavidade. [...]


Assuntos
Antibacterianos , Clorexidina , Cárie Dentária , Dentina , Estética Dentária , Inflamação , Odontalgia
5.
Acta odontol. venez ; 49(1)2011. tab, graf
Artigo em Espanhol | LILACS | ID: lil-678859

RESUMO

El objetivo de este trabajo "in vitro" fue evaluar la resistencia de unión de dos sistemas adhesivos utilizando el ensayo de microtracción, variando el tipo de substrato dentinario. Fueron utilizados 32 terceros molares humanos recientemente extraídos, los cuales fueron divididos en cuatro grupos de acuerdo con la orientación de los túbulos dentinarios (paralelos o perpendiculares) y con el tipo de sistema adhesivo utilizado (convencional o auto-acondicionante). Además de evaluar la resistencia de unión, todas las muestras fueron examinadas visualmente para determinar el tipo de fractura. Posteriormente, los resultados fueron sometidos a análisis estadística, permitiendo concluir que los adhesivos autoacondicionantes poseen un mejor comportamiento, mostrando mayor resistencia de unión a la dentina cuando los túbulos dentinarios están expuestos paralelamente al largo del eje del elemento dentario. Sin embargo cuando los túbulos dentinarios están perpendiculares al eje del diente, los sistemas adhesivos convencional y autoacondicionantes poseen resistencia adhesiva semejante. En cuanto al tipo de fractura de los cuerpos de prueba, las fallas adhesivas son predominantes, independiente del sistema adhesivo utilizado y del tipo de substrato dental


The aim of this in vitro study was to evaluate the microtensile bond strength, for two adhesive systems, varying the dentin substrate. Thirty-two recently extracted third molars human were used, and divided in four groups according to the dentin tubules orientation (parallels and perpendiculars) and the adhesive systems (total-etching and self-etching). The specimens were examined by optical microscope for determined the fracture type. After, the statistical analysis was evaluated, allowing to conclude that the self-etching adhesive systems showed better behavior and greater bond strength for dental substrate, when the dentin tubules were parallel exposited to dental axis. Nevertheless, when the dentin tubules were perpendiculars, the total-etching and self-etching adhesive systems showed similar statistical bond strength values. For the fracture type of the specimens, adhesive fractures were predominant, independent of the adhesive systems and the type of dental substrate used


Assuntos
Cimentos Dentários , Materiais Dentários , Técnicas In Vitro , Ligas Metalo-Cerâmicas
6.
Porto Alegre; s.n; 2005. 59 p. ilus, tab, graf.
Tese em Português | BBO - Odontologia | ID: biblio-863330

RESUMO

O objetivo deste estudo foi avaliar o comportamento de três aparelhos fotoativadores, sendo que dois aparelhos utilizam a tecnologia de diodos emissores de luz (LED) (Radii-SDI; Sigle V-Bio art) e o último é um aparelho convencional de lâmpada halógena (XL-2500-3M ESPE), sendo que o primeiro apresenta o diodo emissor de luz na extremidade do aparelho; o segundo apresenta ponteira de fibra óptica turbo e o terceiro apresenta ponteira de fibra óptica convencional. O desempenho dos aparelhos foi analisado por meio da análise de microdureza do fundo de um incremento de 2mm do compósito Z250 (3M ESPE), submetido à polimerização em diferentes profundidades: 2mm, 4mm, 6mm, e 8mm. Em todos os casos, o tempo de polimerização adotado foi de 20 s. Para obtenção dos corpos de prova, foi utilizada uma matriz de dentina com uma cavidade de 3mm de diâmetro por 2mm de espessura. Para simular as didiferentes profundidades de 2mm, 4mm, 6mm e 8mm, foram utilizados espaçadores de dentina em forma de anel com 2mm, 4mm, e 6mm de espessura sobre a matriz. Para o ensaio de microdureza, foram confeccionados cinco corpos de prova para cada combinação entre o aparelho fotoativador e as quatro profundidades, totalizando 60 corpos de prova. O ensaio foi realizado 15min após a polimerização. Os valores de microdureza foram obtidos a partir de cinco endentações em cada corpo de prova. Os resultados obtidos foram submetidos à análise de variância e ao teste Tukey para comparação entre os aparelhos, em cada profundidade (alfa=0,05). Os valores médios e desvio padrão da microdureza obtidos com aparelhos Radii(R), Single V (S) e XL-2500(XL), a 2mm, foram respectivamente: 55,16(±1,66), 58,56 (±1,77), 51,15 (±2,08), mostrando diferença significativa entre eles , sendo que o melhor desempenho foi obtido pelo S seguido pelo R e pelo XL. A 4mm, os valores foram R= 52,23 (±1,66); S= 49,04 (±2,04); XL= 47,34 (±2,69), com melhor desempenho do R em relação a XL, porém sem diferença do S. A 6mm, os valores foram R= 46,40 (±1,07); S= 43,64 (±1,56); XL= 42,12(±1,72). Com o melhor desempenho do R, seguidos pelo S e XL que não mostraram diferença entre si. Já a 8mm, os valores foram R= 41,96 (±1,09); S= 38,36(±0,87); XL=40,16 (±1,70), com melhor desempenho do R seguido pelo XL e este pelo S, mostrando diferença significativa entre eles. Comparando os aparelhos LED com a lâmpada halógena, pode-se observar que o Radii teve um desempenho superior a ela em todas as profundidades...


Assuntos
Humanos , Resinas Compostas , Luz , Instrumentos Odontológicos , Dureza
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA