Braz J Cardiovasc Surg ; 37(5): 721-726, 2022 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-36346774

RESUMO

INTRODUCTION: The aim of this study was to present the mid-term results of patients who had undergone a carotid-subclavian bypass surgery after a thoracic endovascular aortic repair (TEVAR) stent-graft implantation with proximal landing at zone 2 of the aorta. METHODS: A total of 66 patients had undergone TEVAR and carotid-subclavian bypass between January 2015 and May 2020 at our clinic. Five of these patients were lost to follow-up, so 61 patients were included in this retrospective study. At follow-up visits, patency of the carotid-subclavian bypass grafts was evaluated with physical examination and radiological imaging. RESULTS: The mean follow-up time was 15.11±12.29 months (ranging from 1 to 56 months). There were 3 (4.91%) in-hospital deaths of patients admitted with bilateral lower limb and visceral malperfusion. There were also 2 (3.27%) deaths unrelated to the procedure. Carotid-subclavian graft occlusion occurred in 3 (4.91%) patients. The occlusion was detected with radiological imaging within a period of 12 to 24 months. The graft patency rate was 100% in the first 12 months. The mean graft patency time (survival) was 52.56±2.10 months. CONCLUSION: Periprocedural carotid-subclavian bypass surgery with synthetic grafts is a recommended procedure with high patency and acceptably low mortality and morbidity rates in TEVAR.


Assuntos
Aneurisma da Aorta Torácica , Arteriopatias Oclusivas , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Prótese Vascular , Artéria Subclávia/cirurgia , Procedimentos Endovasculares/métodos , Estudos Retrospectivos , Resultado do Tratamento , Fatores de Tempo , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Arteriopatias Oclusivas/cirurgia , Stents
2.
Rev. bras. cir. cardiovasc ; 37(5): 721-726, Sept.-Oct. 2022. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1407290

RESUMO

ABSTRACT Introduction: The aim of this study was to present the mid-term results of patients who had undergone a carotid-subclavian bypass surgery after a thoracic endovascular aortic repair (TEVAR) stent-graft implantation with proximal landing at zone 2 of the aorta. Methods: A total of 66 patients had undergone TEVAR and carotid-subclavian bypass between January 2015 and May 2020 at our clinic. Five of these patients were lost to follow-up, so 61 patients were included in this retrospective study. At follow-up visits, patency of the carotid-subclavian bypass grafts was evaluated with physical examination and radiological imaging. Results: The mean follow-up time was 15.11±12.29 months (ranging from 1 to 56 months). There were 3 (4.91%) in-hospital deaths of patients admitted with bilateral lower limb and visceral malperfusion. There were also 2 (3.27%) deaths unrelated to the procedure. Carotid-subclavian graft occlusion occurred in 3 (4.91%) patients. The occlusion was detected with radiological imaging within a period of 12 to 24 months. The graft patency rate was 100% in the first 12 months. The mean graft patency time (survival) was 52.56±2.10 months. Conclusion: Periprocedural carotid-subclavian bypass surgery with synthetic grafts is a recommended procedure with high patency and acceptably low mortality and morbidity rates in TEVAR.