Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Orthopade ; 46(4): 359-365, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27832317

RESUMO

INTRODUCTION: To determine the effects of tranexamic acid (TXA) on transfusions in patients undergoing hip replacement with a hybrid or cementless prosthesis. METHODS: A group of 172 consecutive patients aged 18 years or older who underwent elective hip replacement with uncemented or hybrid prostheses, undergoing surgery between January 2012 and January 2014 by the same primary surgeon and anesthesiologist, were retrospectively included. TXA (1 g) was administered immediately before incision in the TXA group. Primary variables included number of red blood cell transfusions and the influence of TXA for each type of prosthesis. Secondary variables included hematocrit at discharge, length of hospital stay, thrombosis or pulmonary embolism, seizures, and death. RESULTS: Average transfusion was 1.53 units/patient in the control group compared to 0.6 units/patient in the TXA group (z = 6.29; U = 1640.5; p < 0.0001). TXA use was significantly correlated with the number of units transfused (p < 0.0001, 95% CI -1.24 to -0.68). Odds risk reduction for transfusion was observed during surgery (OR: 0.14; CI 0.06-0.29; p < 0.0001) and during the rest of hospital stay (OR: 0.11; CI 0.01-0.96; p = 0.046). Both hybrid and cementless prostheses that received TXA were transfused less than control groups (0.57 ± 1 vs. 1.7 ± 1 p < 0.01 and 0.65 ± 1 vs. 1.24 ± 1 p < 0.01). No difference was observed between the groups regarding adverse effects. Hematocrit values at discharge and length of hospital stay were similar between groups. No deaths were observed during hospital stay. CONCLUSIONS: TXA reduced transfusions without increasing the prevalence of adverse effects. This reduction was observed during surgery and the following days of hospital stay for both for hybrid and cementless prosthesis.


Assuntos
Artroplastia de Quadril/estatística & dados numéricos , Perda Sanguínea Cirúrgica/prevenção & controle , Transfusão de Sangue/estatística & dados numéricos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/prevenção & controle , Pré-Medicação/estatística & dados numéricos , Ácido Tranexâmico/administração & dosagem , Idoso , Antifibrinolíticos/administração & dosagem , Argentina/epidemiologia , Perda Sanguínea Cirúrgica/estatística & dados numéricos , Causalidade , Estudos de Coortes , Comorbidade , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Prevalência , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA