1.
J Mech Behav Biomed Mater ; 126: 105019, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34875501

RESUMO

PURPOSE: This study evaluated the effect of different tightening protocols on the probability of survival of screw-retained implant-supported anterior crowns. MATERIALS AND METHODS: Seventy-two implants with internal conical connections (4.0 × 10mm, Ti-6Al-4V, Colosso, Emfils) were divided into four groups (n = 18 each): 1) Manufacturer's recommendations torque (25 N.cm for abutment's screw and 30 N.cm for crown's screw) (MaT); 2) Retightening after 10 min (ReT); 3) Torque 16% below recommended to simulate an uncalibrated wrench (AgT), and; 4) Temporary crown simulation (TeT), where crowns were torqued to 13 N.cm to simulate manual tightening, subjected to 11,200 cycles to simulate temporary crown treatment time (190 N), and then retightened to manufacturer torque (TeT). All specimens were subjected to cyclic fatigue in distilled water with a load of 190 N until 250,000 cycles or failure. The probability of survival (reliability) to complete a mission of 50,000 cycles was calculated and plotted using the Weibull 2-Parameter analysis. Weibull modulus and number of cycles at which 62.3% of the specimens would fail were also calculated and plotted. The failure mode was characterized in stereo and scanning electron microscopes (SEM). RESULTS: The probability of survival was 69.3% for MaT, 70% for ReT, 54.8% for AgT, and 40.3% for TeT, all with no statistically significant difference. Weibull modulus was approximately 1.0 for all groups. The characteristic number of cycles for failure was 105,000 cycles for MaT, 123,000 for ReT, 82,000 cycles for AgT, and 54,900 cycles for TeT, with no significant difference between groups. The chief failure mode for MaT, ReT, AgT groups was crown screw fracture, whereas abutment screw fracture was the chief failure mode for the TeT group. CONCLUSION: Tightening protocol did not influence the probability of survival of the screw-retained anterior crowns supported by internal conical implants (Ti-6Al-4V, Colosso, Emfils).


Assuntos
Coroas , Implantes Dentários , Parafusos Ósseos , Falha de Restauração Dentária , Análise do Estresse Dentário , Probabilidade , Reprodutibilidade dos Testes , Torque
2.
Dent Mater ; 35(3): 511-522, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30686708

RESUMO

OBJECTIVE: To evaluate the probability of survival of monolithic and porcelain veneered lithium disilicate crowns comprised by a conventional or modified core when loaded on marginal ridges. METHODS: Lithium disilicate molar crowns (n=30) were fabricated to be tested at mesial and distal marginal ridges and were divided as follows: (1) bilayered crowns with even-thickness 0.5mm framework (Bi-EV); (2) bilayered crowns with modified core design (Bi-M-lingual collar connected to proximal struts), and: (3) monolithic crowns (MON). After adhesively cemented onto composite-resin prepared replicas, mesial and distal marginal ridges of each crown (n=20) were individually cyclic loaded in water (30-300N) with a ceramic indenter at 2Hz until fracture. The 2-parameter Weibull was used to calculate the probability of survival (reliability) (90% 2-sided confidence bounds) at 1, 2, and 3 million cycles and mean life. RESULTS: The reliability at 1 and 2 million cycles was significantly higher for MON (47% and 19%) compared to Bi-EV (20% and 4%) and Bi-M (17% and 2%). No statistical difference was found between bilayered groups. Only the MON group presented crown survival (7%) at 3 million cycles. The mean life was highest for MON (1.73E+06), lowest for Bi-M (573,384) and intermediate for Bi-E (619,774). Fractographic analysis showed that the fracture originated at the occlusal surface. The highest reliability was found for MON crowns. The modified framework design did not improve the fatigue life of crowns. SIGNIFICANCE: Monolithic lithium disilicate crowns presented higher probability of survival and mean life than bilayered crowns with modified framework design when loaded at marginal ridges.


Assuntos
Porcelana Dentária , Zircônio , Coroas , Planejamento de Prótese Dentária , Teste de Materiais , Reprodutibilidade dos Testes
3.
J Prosthodont ; 27(7): 659-664, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27859976

RESUMO

PURPOSE: To evaluate the reliability of narrow diameter dental implants (NDIs) with similar macrogeometry and 3 implant-abutment connection designs. MATERIALS AND METHODS: Eighty-four NDIs (3.5 × 10 mm) were selected and divided into 4 groups (n = 21/group) according to implant-abutment connection design, as follows: EH - external hexagon, IH - internal hexagon, IC - internal conical, and IC-M - internal conical connected to a monolithic titanium abutment. Identical abutments were torqued to the implants, and standardized maxillary incisor crowns were cemented and subjected to step-stress accelerated life testing (SSALT) in water. Use of level probability Weibull curves, and reliability for a mission of 50,000 cycles at 75 N and 200 N were calculated. RESULTS: The beta (ß) values were: 1.48 for IC, 1.40 for IC-M, 8.54 for EH, and 1.98 for IH, indicating that damage accumulation was an acceleration factor for failure of all groups. At 75 N the probability of survival was not significantly different between groups. A decrease in reliability was observed for all groups at 200 N with no significant differences between IC (81.71%) and IC-M (94.28%), or between EH and IH (0%) which presented the lowest values. EH failures were primarily restricted to the screw, while IH involved screw and implant fracture. IC and IC-M were restricted to prosthetic failures (fracture and bending). CONCLUSIONS: Narrow implants with external or internal hexagon connections presented the lowest reliability at high loads compared to internal conical connections. Failure modes differed among connections.


Assuntos
Coroas , Projeto do Implante Dentário-Pivô , Falha de Restauração Dentária , Análise do Estresse Dentário , Incisivo , Teste de Materiais , Titânio , Torque
4.
J Biomed Mater Res B Appl Biomater ; 105(6): 1481-1489, 2017 08.
Artigo em Inglês | MEDLINE | ID: mdl-27098440

RESUMO

This study evaluated the reliability of implant-supported crowns repaired with resin composites. Fifty-four titanium abutments were divided in three groups (n = 18 each) to support resin nanoceramic molar crowns, as follows: (LU) (Lava Ultimate, 3M ESPE); LU repaired with either a direct or an indirect resin composite. Samples were subjected to mouth-motion accelerated-life testing in water (n = 18). Cumulative damage with a use stress of 300 N was used to plot Weibull curves for group comparison. Reliability was calculated for a mission of 100,000 cycles at 400 N load. Beta values were 0.83 for LU, 0.31 and 0.27 for LU repaired with Filtek and Ceramage, respectively. Weibull modulus for LU was 9.5 and η = 1047 N, m = 6.85, and η = 1002 N for LU repaired with Ceramage, and m = 4.65 and η = 766 N for LU repaired with Filtek (p < 0.10 between LU and LU repaired with Filtek). Reliability at 400 N was 100% for both LU and LU repaired with Ceramage which were significantly higher than LU Filtek repair (32%). LU restored crowns failed cohesively. Fractures were confined within the restored material, and detailed fractography is presented. The performance of resin nanoceramic material repaired with an indirect composite was maintained after accelerated-life testing compared to unrepaired controls. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 1481-1489, 2017.


Assuntos
Resinas Compostas/química , Coroas , Implantes Dentários , Teste de Materiais , Estresse Mecânico , Humanos