Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Clin Med ; 12(2)2023 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-36675431

RESUMO

Self-reported awake bruxism (AB) has been associated with temporomandibular disorders (TMD). However, the daily amount of AB behavior has not been quantified in pain patients. Therefore, this study aimed to assess AB frequency in patients with myofascial pain and temporomandibular joint (TMJ) pain and compare it to a group of pain-free individuals. Eighty-four individuals belonging to either a TMD group (n = 54) or a healthy control group (n = 30) were selected. AB frequency was obtained by ecological momentary assessment with a dedicated smartphone application that sent sound alerts at random intervals during the day for one week. Upon receiving the alert, the volunteer reported the current muscular condition and/or the teeth position, i.e., relaxed jaw muscle, jaw bracing, teeth contact, teeth clenching, or teeth grinding. Data were evaluated by independent t-test (α = 0.05). During the seven days, AB frequency was 62.1% ± 26.8% for TMD patients and 36.2% ± 27.3% for pain-free subjects (p < 0.001). Mandible bracing was most common in the TMD group (p < 0.001), while teeth contact, clenching, and grinding did not differ between groups. Moreover, no differences were found in AB frequency between myofascial pain and TMJ pain patients. Therefore, TMD patients have higher AB frequency characterized by jaw bracing, irrespective of pain location.

2.
Braz Oral Res ; 30(1): e123, 2016 Nov 28.
Artigo em Inglês | MEDLINE | ID: mdl-27901205

RESUMO

Color match and water sorption are two factors that affect restorative materials. Discoloration is essential in the lifespan of restorations. The aim of this study was to evaluate color change and water sorption of nine flowable composites at multiple time points over 6 months. 60 samples of each composite were divided into two groups (Color Change and Water Sorption/Solubility). Each Color Change group was divided into six subgroups, which were immersed in distilled water (DW), coffee (CF), Coca-Cola (CC), red wine (RW), tea (TE) and orange juice (OJ). The color was measured at the baseline, 1, 2, 3 and 4 weeks, and 3 and 6 months and color change values (ΔE) were calculated. Each Water Sorption [WS]/Solubility [WL] group was tested according to ISO 4049:2009. The data were evaluated using two-way ANOVA, Fisher's post-hoc test and Pearson's correlation test. The composite with the lowest ΔE differed for each solution: Filtek™ Bulk Fill in DW (∆E = 0.73 (0.17-1.759)); Vertise Flow in CF (∆E = 14.75 (7.91-27.41)), in TE (∆E = 7.27 (2.81-24.81)) and OJ (∆E = 3.17 (0.87-9.92)); Tetric EvoFlow® in CC (∆E = 1.27 (0.45-4.02)); and Filtek™ Supreme XTE in RW (∆E = 8.88 (5.23-19.59)). RW caused the most discoloration (∆E = 23.62 (4.93-51.36)). Vertise Flow showed the highest water sorption (WS = 69.10 ± 7.19). The Pearson test showed statistically significant positive correlations between water sorption and solubility and between water sorption and ∆E; the positive solubility-∆E correlation was not statistically significant. The findings suggest that water sorption is one factor associated with the ability of composites to discolor; however, discoloration is a multifactorial problem.


Assuntos
Resinas Compostas/química , Pigmentação em Prótese , Água/química , Análise de Variância , Bebidas , Cor , Colorimetria , Imersão , Teste de Materiais , Valores de Referência , Reprodutibilidade dos Testes , Solubilidade , Estatísticas não Paramétricas , Propriedades de Superfície , Fatores de Tempo
3.
Braz. oral res. (Online) ; 30(1): e123, 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-952034

RESUMO

Abstract Color match and water sorption are two factors that affect restorative materials. Discoloration is essential in the lifespan of restorations. The aim of this study was to evaluate color change and water sorption of nine flowable composites at multiple time points over 6 months. 60 samples of each composite were divided into two groups (Color Change and Water Sorption/Solubility). Each Color Change group was divided into six subgroups, which were immersed in distilled water (DW), coffee (CF), Coca-Cola (CC), red wine (RW), tea (TE) and orange juice (OJ). The color was measured at the baseline, 1, 2, 3 and 4 weeks, and 3 and 6 months and color change values (ΔE) were calculated. Each Water Sorption [WS]/Solubility [WL] group was tested according to ISO 4049:2009. The data were evaluated using two-way ANOVA, Fisher's post-hoc test and Pearson's correlation test. The composite with the lowest ΔE differed for each solution: Filtek™ Bulk Fill in DW (∆E = 0.73 (0.17-1.759)); Vertise Flow in CF (∆E = 14.75 (7.91-27.41)), in TE (∆E = 7.27 (2.81-24.81)) and OJ (∆E = 3.17 (0.87-9.92)); Tetric EvoFlow® in CC (∆E = 1.27 (0.45-4.02)); and Filtek™ Supreme XTE in RW (∆E = 8.88 (5.23-19.59)). RW caused the most discoloration (∆E = 23.62 (4.93-51.36)). Vertise Flow showed the highest water sorption (WS = 69.10 ± 7.19). The Pearson test showed statistically significant positive correlations between water sorption and solubility and between water sorption and ∆E; the positive solubility-∆E correlation was not statistically significant. The findings suggest that water sorption is one factor associated with the ability of composites to discolor; however, discoloration is a multifactorial problem.


Assuntos
Água/química , Pigmentação em Prótese , Resinas Compostas/química , Valores de Referência , Solubilidade , Propriedades de Superfície , Fatores de Tempo , Bebidas , Teste de Materiais , Reprodutibilidade dos Testes , Análise de Variância , Cor , Colorimetria , Estatísticas não Paramétricas , Imersão
4.
J. appl. oral sci ; 20(6): 613-619, Nov.-Dec. 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-660631

RESUMO

OBJECTIVE: This study evaluated the performance of different adhesive systems in fiber post placement aiming to clarify the influence of different hydrophobic experimental blend adhesives, and of one commercially available adhesive on the frictional retention during a luting procedure. MATERIAL AND METHODS: One luting agent (70 Wt% BisGMA, 28.5% TEGDMA; 1.5% p-tolyldiethanolamine) to cement fiber posts into root canals was applied with 4 different adhesive combinations: Group 1: The etched roots were rinsed with water for 30 s to remove the phosphoric acid, then rinsed with 99.6% ethanol for 30 s, and blotdried. A trial adhesive (base to catalyst on a 1:1 ratio) was used with an experimental luting agent (35% Bis-GMA, 14.37% TeGDMA, 0.5% eDMAB, 0.13% CQ); Group 2: A trial adhesive (base to catalyst on a 1:2 ratio) was luted as in Group 1; Group 3: One-Step Plus (OSP, Bisco Inc.) following the ethanol bonding technique in combination with the luting agent as in Group 1; Group 4: OSP strictly following the manufacturer's instructions using the luting agent as in Group 1. The groups were challenged with push-out tests. Posted root slices were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under scanning electron microscopy. RESULTS: Push-out strength was not significantly influenced by the luting agent (p>0.05). No statistically significant differences among the tested groups were found as Group 1 (exp 1 - ethanol-wet bonding technique)=Group 2 (exp 2 - ethanol-wet bonding technique)=Group 3 (OSP - ethanol-wet bonding technique)=Group 4 (control, OSP - water-wet bonding technique) (p>0.05). The dominating failure modes in all the groups were cohesive/adhesive failures, which were predominantly observed on the post/luting agent interface. CONCLUSIONS: The results of this study support the hypothesis that the proposal to replace water with ethanol to bond fiber posts to the root canal using highly hydrophobic resin is plausible, but this seems to be more the proof of a concept than a clinically applicable procedure.


Assuntos
Humanos , Colagem Dentária/métodos , Cavidade Pulpar/química , Adesivos Dentinários/química , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular , Falha de Restauração Dentária , Cavidade Pulpar/efeitos dos fármacos , Dentina/química , Dentina/efeitos dos fármacos , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Distribuição Aleatória , Estatísticas não Paramétricas , Propriedades de Superfície
5.
J Appl Oral Sci ; 20(6): 613-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23329242

RESUMO

OBJECTIVE: This study evaluated the performance of different adhesive systems in fiber post placement aiming to clarify the influence of different hydrophobic experimental blend adhesives, and of one commercially available adhesive on the frictional retention during a luting procedure. MATERIAL AND METHODS: One luting agent (70 Wt% BisGMA, 28.5% TEGDMA; 1.5% p-tolyldiethanolamine) to cement fiber posts into root canals was applied with 4 different adhesive combinations: group 1: The etched roots were rinsed with water for 30 s to remove the phosphoric acid, then rinsed with 99.6% ethanol for 30 s, and blotdried. A trial adhesive (base to catalyst on a 1:1 ratio) was used with an experimental luting agent (35% Bis-GMA, 14.37% TeGDMA, 0.5% eDMAB, 0.13% CQ); group 2: A trial adhesive (base to catalyst on a 1:2 ratio) was luted as in group 1; group 3: One-Step Plus (OSP, Bisco Inc.) following the ethanol bonding technique in combination with the luting agent as in group 1; group 4: OSP strictly following the manufacturer's instructions using the luting agent as in group 1. The groups were challenged with push-out tests. Posted root slices were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under scanning electron microscopy. RESULTS: Push-out strength was not significantly influenced by the luting agent (p>0.05). No statistically significant differences among the tested groups were found as group 1 (exp 1--ethanol-wet bonding technique)=group 2 (exp 2--ethanol-wet bonding technique)=Group 3 (OSP--ethanol-wet bonding technique)=group 4 (control, OSP--water-wet bonding technique) (p>0.05). The dominating failure modes in all the groups were cohesive/adhesive failures, which were predominantly observed on the post/luting agent interface. CONCLUSIONS: The results of this study support the hypothesis that the proposal to replace water with ethanol to bond fiber posts to the root canal using highly hydrophobic resin is plausible, but this seems to be more the proof of a concept than a clinically applicable procedure.


Assuntos
Colagem Dentária/métodos , Cavidade Pulpar/química , Adesivos Dentinários/química , Microscopia Eletrônica de Varredura , Técnica para Retentor Intrarradicular , Cavidade Pulpar/efeitos dos fármacos , Falha de Restauração Dentária , Dentina/química , Dentina/efeitos dos fármacos , Humanos , Interações Hidrofóbicas e Hidrofílicas , Teste de Materiais , Distribuição Aleatória , Estatísticas não Paramétricas , Propriedades de Superfície
7.
J Adhes Dent ; 11(1): 65-70, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19343929

RESUMO

PURPOSE: The study evaluates the behavior of different adhesive systems and resin cements in fiber post placement, with the intent to clarify the possible role of unfilled resin as a luting material for fiber posts. MATERIALS AND METHODS: Two luting agents (Dual-Link and Unfilled Resin) for cementing fiber posts into root canals were applied either with All-Bond 2 or One-Step Plus, or without an adhesive system, and challenged with the push-out test. Slices of roots restored with posts were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under SEM. RESULTS: Push-out strength was significantly influenced by the luting agent (p < 0.05), but not by the bonding strategy (p > 0.05). The best results were obtained in combination with Unfilled Resin with One-Step Plus. Dual-Link groups failed mainly cohesively within the cement, while Unfilled Resin demonstrated more adhesive fracture at the post interface. CONCLUSION: The results of this study support the hypothesis that adhesive unfilled resin application is essential for achieving high bond strength to radicular dentin.


Assuntos
Cimentação/métodos , Colagem Dentária , Técnica para Retentor Intrarradicular/instrumentação , Cimentos de Resina/química , Condicionamento Ácido do Dente , Adolescente , Bis-Fenol A-Glicidil Metacrilato/química , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Adesivos Dentinários/química , Humanos , Umidade , Teste de Materiais , Metacrilatos/química , Microscopia Eletrônica de Varredura , Polietilenoglicóis/química , Ácidos Polimetacrílicos/química , Poliuretanos/química , Preparo de Canal Radicular , Estresse Mecânico , Temperatura , Fatores de Tempo
8.
Am J Dent ; 21(1): 30-4, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18435373

RESUMO

PURPOSE: To evaluate early and 24-hour microtensile bond strength (microTBS) and the degree of conversion (DC) of one representative adhesive system from each of the four current bonding approaches. METHODS: 40 human molars were sectioned occluso-gingivally into two halves. Resin composite was bonded incrementally to flat, mid-coronal dentin, using the adhesives Adper Scotchbond MP (MP); Adper Scotchbond 2 (SB); Clearfil SE Bond (SE); and Adper Prompt L-Pop (LP) according to the respective manufacturer's instructions (n = 10). One half was immediately sectioned into sticks and subjected to muTBS test. As the sectioning process took approximately 1 hour, the results were designated as 1-hour bond strengths. The other half was stored in distilled water at 37 degrees C for 24 hours before being sectioned and tested. The DC of these systems was measured using Fourier Transform-Raman spectroscopy in three periods: immediately, 1 and 24 hours after polymerization. Data were analyzed with ANOVA and Tukey's tests. RESULTS: There were no significant differences between the 1-hour and 24-hour bond strengths (P > 0.05), or among the DC measured immediately, 1 hour and 24 hours after polymerization (P > 0.05). However, significant differences were observed among adhesives (P < 0.05). microTBS values obtained, in MPa (1 hour/24 hour), were: SB (48.6 + 1.3/48.4 + 3.5) = SE (51.9 + 4.7/53.3 +/- 2.9) > MP (35.3 +/- 10.9/38.6 + 6.7) > LP (25.5 + 1.1/26.0 + 1.5). The DC, in percentage (immediately/1 hour/24 hour), were: SE (81/82/87) > MP (79/77/81) > SB (60/63/65) > LP (39/37/42).


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Adesivos Dentinários/química , Resinas Compostas/química , Materiais Dentários/química , Dentina/ultraestrutura , Humanos , Teste de Materiais , Polímeros/química , Cimentos de Resina/química , Espectroscopia de Infravermelho com Transformada de Fourier , Análise Espectral Raman , Estresse Mecânico , Temperatura , Resistência à Tração , Fatores de Tempo , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA