Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Med Virol ; 96(5): e29621, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38654686

RESUMO

Mpox is a zoonotic disease historically reported in Africa. Since 2003, limited outbreaks have occurred outside Africa. In 2022, the global spread of cases with sustained interhuman transmission and unusual disease features raised public health concerns. We explore the mpox outbreak in Rio de Janeiro (RJ) state, Brazil, in an observational study of mpox-suspected cases from June to December 2022. Data collection relied on a public healthcare notification form. Diagnosis was determined by MPXV-PCR. In 46 confirmed cases, anti-OPXV IgG was determined by ELISA, and seven MPXV genomes were sequenced. A total of 3095 cases were included, 816 (26.3%) with positive MPXV-PCR results. Most positive cases were men in their 30 s and MSM. A total of 285 (34.9%) MPXV-PCR+ patients live with HIV. Eight were coinfected with varicella-zoster virus. Anogenital lesions and adenomegaly were associated with the diagnosis of mpox. Females and individuals under 18 represented 9.4% and 5.4% of all confirmed cases, respectively, showing higher PCR cycle threshold (Ct) values and fewer anogenital lesions compared to adult men. Anti-OPXV IgG was detected in 29/46 (63.0%) patients. All analyzed sequences belonged to clade IIb. In RJ state, mpox presented a diverse clinical picture, represented mainly by mild cases with low complication rates and prominent genital involvement. The incidence in females and children was higher than usually reported. The observation of a bimodal distribution of Ct values, with few positive results, may suggest the need to review the diagnostic criteria in these groups.


Assuntos
Surtos de Doenças , Humanos , Brasil/epidemiologia , Masculino , Feminino , Adulto , Adulto Jovem , Adolescente , Pessoa de Meia-Idade , Animais , Zoonoses/epidemiologia , Zoonoses/virologia , Herpesvirus Humano 3/genética , Herpesvirus Humano 3/isolamento & purificação , Criança , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Anticorpos Antivirais/sangue , Idoso , Imunoglobulina G/sangue
2.
Microbiol Spectr ; 10(6): e0201222, 2022 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-36448777

RESUMO

The COVID-19 pandemic has led to the commercialization of many antigen-based rapid diagnostic tests (Ag-RDTs), requiring independent evaluations. This report describes the clinical evaluation of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom. The collected samples (446 nasal swabs from Brazil and 246 nasopharyngeal samples from the UK) were analyzed by the Ag-RDT and compared to reverse transcription-quantitative PCR (RT-qPCR). Analytical evaluation of the Ag-RDT was performed using direct culture supernatants of SARS-CoV-2 strains from the wild-type (B.1), Alpha (B.1.1.7), Delta (B.1.617.2), Gamma (P.1), and Omicron (B.1.1.529) lineages. An overall sensitivity and specificity of 88.2% (95% confidence interval [CI], 81.3 to 93.3) and 100.0% (95% CI, 99.1 to 100.0), respectively, were obtained for the Brazilian and UK cohorts. The analytical limit of detection was determined as 1.0 × 103 PFU/mL (Alpha), 2.5 × 102 PFU/mL (Delta), 2.5 × 103 PFU/mL (Gamma), and 1.0 × 103 PFU/mL (Omicron), giving a viral copy equivalent of approximately 2.1 × 104 copies/mL, 9.0 × 105 copies/mL, 1.7 × 106 copies/mL, and 1.8 × 105 copies/mL for the Ag-RDT, respectively. Overall, while a higher sensitivity was claimed by the manufacturers than that found in this study, this evaluation finds that the Ag-RDT meets the WHO minimum performance requirements for sensitivity and specificity of COVID-19 Ag-RDTs. This study illustrates the comparative performance of the Hotgen Ag-RDT across two global settings and considers the different approaches in evaluation methods. IMPORTANCE Since the beginning of the SARS-CoV-2 pandemic, we have witnessed growing numbers of antigen rapid diagnostic tests (Ag-RDTs) being brought to market. In the United Kingdom, this was somewhat controlled indirectly as the government offered free tests from a small number of companies. However, as this has now ceased, individuals are responsible for their own acquisition of test kits. Similarly in Brazil, as of January 2022, pharmacies and other health care retailers are permitted to sell Ag-RDTs directly to the community. Many of these Ag-RDTs have not been externally evaluated, and results are not readily available to the public. Thus, there is now a need for a transparent evaluation of Ag-RDTs with both analytical and clinical evaluation. We present an independent review of the Novel Coronavirus 2019-nCoV Antigen Test (Colloidal Gold) (Beijing Hotgen Biotech Co., Ltd.), at two sites within Brazil and one in the United Kingdom.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , Brasil , COVID-19/diagnóstico , Pandemias , Reino Unido , Coloide de Ouro
3.
Front Immunol ; 13: 884760, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35844561

RESUMO

The SARS-CoV-2 pandemic has had a social and economic impact worldwide, and vaccination is an efficient strategy for diminishing those damages. New adjuvant formulations are required for the high vaccine demands, especially adjuvant formulations that induce a Th1 phenotype. Herein we assess a vaccination strategy using a combination of Alum and polyinosinic:polycytidylic acid [Poly(I:C)] adjuvants plus the SARS-CoV-2 spike protein in a prefusion trimeric conformation by an intradermal (ID) route. We found high levels of IgG anti-spike antibodies in the serum by enzyme linked immunosorbent assay (ELISA) and high neutralizing titers against SARS-CoV-2 in vitro by neutralization assay, after two or three immunizations. By evaluating the production of IgG subtypes, as expected, we found that formulations containing Poly(I:C) induced IgG2a whereas Alum did not. The combination of these two adjuvants induced high levels of both IgG1 and IgG2a. In addition, cellular immune responses of CD4+ and CD8+ T cells producing interferon-gamma were equivalent, demonstrating that the Alum + Poly(I:C) combination supported a Th1 profile. Based on the high neutralizing titers, we evaluated B cells in the germinal centers, which are specific for receptor-binding domain (RBD) and spike, and observed that more positive B cells were induced upon the Alum + Poly(I:C) combination. Moreover, these B cells produced antibodies against both RBD and non-RBD sites. We also studied the impact of this vaccination preparation [spike protein with Alum + Poly(I:C)] in the lungs of mice challenged with inactivated SARS-CoV-2 virus. We found a production of IgG, but not IgA, and a reduction in neutrophil recruitment in the bronchoalveolar lavage fluid (BALF) of mice, suggesting that our immunization scheme reduced lung inflammation. Altogether, our data suggest that Alum and Poly(I:C) together is a possible adjuvant combination for vaccines against SARS-CoV-2 by the intradermal route.


Assuntos
COVID-19 , Vacinas Virais , Adjuvantes Imunológicos , Compostos de Alúmen , Animais , Linfócitos T CD8-Positivos , Vacinas contra COVID-19 , Humanos , Imunoglobulina G , Camundongos , Poli I-C , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus
4.
Biochem Eng J ; 186: 108537, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35874089

RESUMO

Serological tests detect antibodies generated by infection or vaccination, and are indispensable tools along different phases of a pandemic, from early monitoring of pathogen spread up to seroepidemiological studies supporting immunization policies. This work discusses the development of an accurate and affordable COVID-19 antibody test, from production of a recombinant protein antigen up to test validation and economic analysis. We first developed a cost-effective, scalable technology to produce SARS-COV-2 spike protein and then used this antigen to develop an enzyme-linked immunosorbent assay (ELISA). A receiver operator characteristic (ROC) analysis allowed optimizing the cut-off and confirmed the high accuracy of the test: 98.6% specificity and 95% sensitivity for 11+ days after symptoms onset. We further showed that dried blood spots collected by finger pricking on simple test strips could replace conventional plasma/serum samples. A cost estimate was performed and revealed a final retail price in the range of one US dollar, reflecting the low cost of the ELISA test platform and the elimination of the need for venous blood sampling and refrigerated sample handling in clinical laboratories. The presented workflow can be completed in 4 months from first antigen expression to final test validation. It can be applied to other pathogens and in future pandemics, facilitating reliable and affordable seroepidemiological surveillance also in remote areas and in low-income countries.

5.
Virus Evol ; 7(2): veab078, 2021 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-34642605

RESUMO

Long-term infection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) represents a challenge to virus dispersion and the control of coronavirus disease 2019 (COVID-19) pandemic. The reason why some people have prolonged infection and how the virus persists for so long are still not fully understood. Recent studies suggested that the accumulation of intra-host single nucleotide variants (iSNVs) over the course of the infection might play an important role in persistence as well as emergence of mutations of concern. For this reason, we aimed to investigate the intra-host evolution of SARS-CoV-2 during prolonged infection. Thirty-three patients who remained reverse transcription polymerase chain reaction (RT-PCR) positive in the nasopharynx for on average 18 days from the symptoms onset were included in this study. Whole-genome sequences were obtained for each patient at two different time points. Phylogenetic, populational, and computational analyses of viral sequences were consistent with prolonged infection without evidence of coinfection in our cohort. We observed an elevated within-host genomic diversity at the second time point samples positively correlated with cycle threshold (Ct) values (lower viral load). Direct transmission was also confirmed in a small cluster of healthcare professionals that shared the same workplace by the presence of common iSNVs. A differential accumulation of missense variants between the time points was detected targeting crucial structural and non-structural proteins such as Spike and helicase. Interestingly, longitudinal acquisition of iSNVs in Spike protein coincided in many cases with SARS-CoV-2 reactive and predicted T cell epitopes. We observed a distinguishing pattern of mutations over the course of the infection mainly driven by increasing A→U and decreasing G→A signatures. G→A mutations may be associated with RNA-editing enzyme activities; therefore, the mutational profiles observed in our analysis were suggestive of innate immune mechanisms of the host cell defense. Therefore, we unveiled a dynamic and complex landscape of host and pathogen interaction during prolonged infection of SARS-CoV-2, suggesting that the host's innate immunity shapes the increase of intra-host diversity. Our findings may also shed light on possible mechanisms underlying the emergence and spread of new variants resistant to the host immune response as recently observed in COVID-19 pandemic.

7.
J Clin Virol ; 122: 104212, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31765957

RESUMO

BACKGROUND: A new point-of-care (POC) HIV virus load technology has been recently developed and designed to be utilized in decentralized settings. Alere Technologies GmbH*, Germany, developed the mPIMA HIV-1/2 VL plasma test which uses real time PCR technology with 50 µl and a turnaround time of one hour. OBJECTIVE: Analyze the performance of mPIMA to detect and quantify HIV-1 and HIV-2 and compare with Abbott M2000 assay fooling patients HIV-1 failing ARV therapy. STUDY DESIGN: In this study we evaluate the mPIMA HIV-1/2 VL plasma test using 413 specimens from 270 patients failing ARV therapy, and compared its performance with Abbott RealTime HIV-1 Viral Load assay on the m2000 system. In addition, were determined VL in plasma specimens obtained from HIV-2 infected patients. RESULTS: The results strongly indicate that mPIMA HIV-1/2 VL plasma test can determine HIV-1 with concordance of 88.9 % (95 % CI 85.4-91.7) the reference test when 1000 HIV-1 VL threshold was used as WHO cutoff to identify therapy failure. The overall correlation between HIV-1 VL was 0928 (Pearson correlation coefficient of Linear regression) and the Bland-Altman showed a mean difference of -0.20 Log cp/mL between the two technology. mPIMA HIV-1/2 VL plasma test was also able to measure HIV-2 viral load in 16 specimens from Guinea-Bissau HIV-1/HIV-2 positive samples. CONCLUSIONS: These data support the use of mPIMA HIV-1/2 VL plasma test to follow up patients and select patients failing ART, guiding immediate clinical decisions such as adherence counseling or ART regimen switch during the patient consultation.


Assuntos
Infecções por HIV/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito/normas , RNA Viral/sangue , Carga Viral/instrumentação , Carga Viral/métodos , Fármacos Anti-HIV/uso terapêutico , Alemanha , Infecções por HIV/sangue , Infecções por HIV/tratamento farmacológico , HIV-1/isolamento & purificação , HIV-2/isolamento & purificação , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
8.
Braz J Infect Dis ; 24(1): 30-33, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31760036

RESUMO

A new point-of-care HIV viral load, mPIMA HIV-1/2 VL, Abbott, USA, has been recently developed. This point-of-care viral load requires no skilled person to run and uses a small plasma volume (50µL). However, obtaining 50µL of plasma can be a challenge in limited resource settings. We validated a simple and easy method to obtain enough amount of plasma to run a point-of-care viral load. The study utilized 149 specimens from patients failing antiretroviral therapy. At least 250µL of whole blood was collected in a microtube/EDTA from fingerstick (fs-plasma) and immediately centrifuged. Parallel collection of venous blood to obtain plasma (vp-plasma) was used to compare performance in a point-of-care viral load assay and in methodology used in centralized laboratories Abbott M2000, Abbott, USA. The procedure for plasma collection takes less than 10min and in 94% of the cases only one fingerstick was sufficient to collect at least 250µL of blood. The Pearson correlation coefficient value for vp-plasma versus fs-plasma ran on mPIMA was 0.990. The Bland-Altman mean difference (md) for this comparison were virtually zero (md=-0.001) with limits of agreement between -0.225 and 0.223. In addition, the Pearson correlation coefficient value for fs-plasma in mPIMA versus vp-plasma in Abbott M2000 was 0.948 for values above the mPIMA limit of quantification (LoQ; from 800 to 1,000,000copies/mL). These results validate this simple plasma isolation method capable to be implemented in low resource countries where point-of-care decentralization is deeply needed.


Assuntos
HIV/isolamento & purificação , Plasma/virologia , Sistemas Automatizados de Assistência Junto ao Leito , Carga Viral/métodos , Estudos de Viabilidade , Infecções por HIV/sangue , Infecções por HIV/virologia , Humanos , Modelos Lineares , Reprodutibilidade dos Testes
10.
JAMA Neurol ; 73(12): 1407-1416, 2016 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-27695855

RESUMO

IMPORTANCE: Recent studies have reported an increase in the number of fetuses and neonates with microcephaly whose mothers were infected with the Zika virus (ZIKV) during pregnancy. To our knowledge, most reports to date have focused on select aspects of the maternal or fetal infection and fetal effects. OBJECTIVE: To describe the prenatal evolution and perinatal outcomes of 11 neonates who had developmental abnormalities and neurological damage associated with ZIKV infection in Brazil. DESIGN, SETTING, AND PARTICIPANTS: We observed 11 infants with congenital ZIKV infection from gestation to 6 months in the state of Paraíba, Brazil. Ten of 11 women included in this study presented with symptoms of ZIKV infection during the first half of pregnancy, and all 11 had laboratory evidence of the infection in several tissues by serology or polymerase chain reaction. Brain damage was confirmed through intrauterine ultrasonography and was complemented by magnetic resonance imaging. Histopathological analysis was performed on the placenta and brain tissue from infants who died. The ZIKV genome was investigated in several tissues and sequenced for further phylogenetic analysis. MAIN OUTCOMES AND MEASURES: Description of the major lesions caused by ZIKV congenital infection. RESULTS: Of the 11 infants, 7 (63.6%) were female, and the median (SD) maternal age at delivery was 25 (6) years. Three of 11 neonates died, giving a perinatal mortality rate of 27.3%. The median (SD) cephalic perimeter at birth was 31 (3) cm, a value lower than the limit to consider a microcephaly case. In all patients, neurological impairments were identified, including microcephaly, a reduction in cerebral volume, ventriculomegaly, cerebellar hypoplasia, lissencephaly with hydrocephalus, and fetal akinesia deformation sequence (ie, arthrogryposis). Results of limited testing for other causes of microcephaly, such as genetic disorders and viral and bacterial infections, were negative, and the ZIKV genome was found in both maternal and neonatal tissues (eg, amniotic fluid, cord blood, placenta, and brain). Phylogenetic analyses showed an intrahost virus variation with some polymorphisms in envelope genes associated with different tissues. CONCLUSIONS AND RELEVANCE: Combined findings from clinical, laboratory, imaging, and pathological examinations provided a more complete picture of the severe damage and developmental abnormalities caused by ZIKV infection than has been previously reported. The term congenital Zika syndrome is preferable to refer to these cases, as microcephaly is just one of the clinical signs of this congenital malformation disorder.


Assuntos
Artrogripose/etiologia , Hidrocefalia/etiologia , Malformações do Sistema Nervoso/etiologia , Complicações Infecciosas na Gravidez , Infecção por Zika virus/complicações , Zika virus , Anormalidades Múltiplas/etiologia , Brasil , Cerebelo/patologia , Cérebro/patologia , Feminino , Seguimentos , Humanos , Lactente , Morte do Lactente , Recém-Nascido , Lisencefalia/etiologia , Masculino , Microcefalia/etiologia , Morte Perinatal , Gravidez , Zika virus/genética , Zika virus/isolamento & purificação , Zika virus/patogenicidade , Infecção por Zika virus/congênito
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA