Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Ultrasonics ; 111: 106339, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33352452

RESUMO

Even though the pulse-echo ultrasonic technique is commonly used for the assessment of metal structures, it has some inherent limitations. Vibro-acoustography (VA) is a relatively new ultrasonic technique which has demonstrated a great potential in revealing defects in objects, however it is traditionally used to analyze the integrity of specimens made of low-stiffness materials. This work presents the evaluation of the performance of VA technique for the inspection of a steel structure, which was manufactured with defects of known geometry on its inner surface. All the inspection process was done automatically, from the data acquisition to the image processing for characterizing the defects. Experimental results show that VA was able to identify and characterize even the smallest defects in the structure, with a diameter of 2 mm. In addition, the results show that VA was able to characterize the artificial defects in the steel structure with almost the same errors as the traditional pulse-echo method, which indicates a potential use of VA in the inspection of materials with high mechanical stiffness.

2.
J Acoust Soc Am ; 130(1): EL25-31, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21786864

RESUMO

The pressure-particle velocity (PU) impedance measurement technique is an experimental method used to measure the surface impedance and the absorption coefficient of acoustic samples in situ or under free-field conditions. In this paper, the measurement uncertainty of the the absorption coefficient determined using the PU technique is explored applying the Monte Carlo method. It is shown that because of the uncertainty, it is particularly difficult to measure samples with low absorption and that difficulties associated with the localization of the acoustic centers of the sound source and the PU sensor affect the quality of the measurement roughly to the same extent as the errors in the transfer function between pressure and particle velocity do.


Assuntos
Acústica , Modelos Estatísticos , Método de Monte Carlo , Som , Incerteza , Absorção , Acústica/instrumentação , Simulação por Computador , Desenho de Equipamento , Movimento (Física) , Porosidade , Pressão , Propriedades de Superfície , Fatores de Tempo , Transdutores de Pressão
3.
ISA Trans ; 50(3): 513-20, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21334618

RESUMO

Refrigerant compressor performance tests play an important role in the evaluation of the energy characteristics of the compressor, enabling an increase in the quality, reliability, and efficiency of these products. Due to the nonexistence of a refrigerating capacity standard, it is common to use previously conditioned compressors for the intercomparison and evaluation of the temporal drift of compressor performance test panels. However, there are some limitations regarding the use of these specific compressors as standards. This study proposes the development of a refrigerating capacity standard which consists of a mass flow meter and a variable-capacity compressor, whose speed is set based on the mass flow rate measured by the meter. From the results obtained in the tests carried out on a bench specifically developed for this purpose, it was possible to validate the concept of a capacity standard.


Assuntos
Algoritmos , Modelos Teóricos , Refrigeração/instrumentação , Refrigeração/métodos , Reologia/instrumentação , Reologia/métodos , Simulação por Computador , Análise de Falha de Equipamento/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA