Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Eur J Oral Sci ; 132(4): e12992, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38771146

RESUMO

Finite element analysis (FEA) has been used to analyze the behavior of dental materials, mainly in implantology. However, FEA is a mechanical analysis and few studies have tried to simulate the biological characteristics of the healing process of loaded implants. This study used the rule of mixtures to simulate the biological healing process of immediate implants in an alveolus socket and bone-implant junction interface through FEA. Three-dimensional geometric models of the structures were obtained, and material properties were derived from the literature. The rule of mixtures was used to simulate the healing periods-immediate and early loading, in which the concentration of each cell type, based on in vivo studies, influenced the final elastic moduli. A 100 N occlusal load was simulated in axial and oblique directions. The models were evaluated for maximum and minimum principal strains, and the bone overload was assessed through Frost's mechanostat. There was a higher strain concentration in the healing regions and cortical bone tissue near the cervical portion. The bone overload was higher in the immediate load condition. The method used in this study may help to simulate the biological healing process and could be useful to relate FEA results to clinical practice.


Assuntos
Implantes Dentários , Módulo de Elasticidade , Análise de Elementos Finitos , Carga Imediata em Implante Dentário , Alvéolo Dental , Cicatrização , Humanos , Alvéolo Dental/fisiologia , Cicatrização/fisiologia , Fenômenos Biomecânicos , Simulação por Computador , Interface Osso-Implante/fisiologia , Estresse Mecânico , Processo Alveolar/fisiologia , Modelos Biológicos , Osseointegração/fisiologia , Força de Mordida , Análise do Estresse Dentário/métodos , Osteoblastos/fisiologia , Osso Cortical/fisiologia , Imageamento Tridimensional/métodos
2.
Comput Methods Biomech Biomed Engin ; 23(14): 1127-1137, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32657618

RESUMO

Contraction due to polymerization of dental resin can cause failure on the adhesive interfaces, can lead to problems such as the appearance of gaps in the interfaces, postoperative sensitivity, pulp damage and the return of the caries. The objective of this work is the study of stresses on the dental adhesive that are generated by the process shrinkage of resin associated with biting forces. A laboratory experiment measured the strains and temperature inside the FiltekTM Bulk Fill Flow resin during the process of polymerization using Fiber Bragg Grating sensors in an ex vivo tooth. From tomographic images a three-dimensional geometric model of the tooth was reconstructed. A pre-tension was calibrated to simulate the residual contraction on the resin 3 D model. Finally, an Finite Element Method analysis was performed to access the adhesive stresses at the interface enamel/dentin with the adhesive, considering as loading the residual polymerization contraction of the dental resin and also biting loads. The model was able to represented the strain obtained in the laboratory experiment. The results of the stress analysis shows that the outer regions of adhesive are more prone to failure, as veried by dental surgeons in clinical practice.


Assuntos
Resinas Compostas/química , Análise de Elementos Finitos , Óptica e Fotônica/métodos , Adulto , Fenômenos Biomecânicos , Força de Mordida , Calibragem , Colagem Dentária , Análise do Estresse Dentário , Humanos , Imageamento Tridimensional , Teste de Materiais , Polimerização , Pressão , Temperatura , Adulto Jovem
3.
Rev. bras. ortop ; 53(5): 564-569, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-977875

RESUMO

ABSTRACT Objective: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. Methods: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. Results: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. Conclusion: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


RESUMO Objetivo: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. Métodos: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. Resultados: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. Conclusão: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.


Assuntos
Animais , Dispositivos de Fixação Ortopédica , Tendões , Tíbia , Fenômenos Biomecânicos , Ligamento Cruzado Anterior
4.
Rev Bras Ortop ; 53(5): 564-569, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30245995

RESUMO

OBJECTIVE: The aim of the study was to compare the mechanical behavior of interference screw tibial fixation vs. screw-plus-staple tibial fixation in an animal model. METHODS: Thirty-six pieces of swine knee specimens were selected and divided into two groups: Group 1, tibial fixation with interference screw (n = 17), and Group 2, fixation with interference screw and staple (n = 19). The models were submitted to a single cycle of tension testing. The following variables were measured: graft cross-sectional area, failure point on 10 mm (F10), yield load (Fy), and stiffness. RESULTS: The mean values of graft cross-sectional area, F10, Fy, and stiffness did not present significant differences between the groups. CONCLUSION: The addition of a second staple-type ligament fixation device, complementing the interference screw, did not increase the mechanical safety of the system.


OBJETIVO: Comparar o comportamento mecânico da fixação tibial com parafuso de interferência versus parafuso de interferência com agrafe, em modelo animal. MÉTODOS: Foram selecionadas 36 peças de joelho suíno e divididas em dois grupos: Grupo 1, fixação tibial com parafuso de interferência (n = 17) e Grupo 2, fixação com parafuso de interferência e agrafe (n = 19). Os modelos foram submetidos a teste de ciclo único de tração. Foram mensuradas as seguintes variáveis: medida da área de seção transversal do enxerto, ponto de falha nos 10 mm (F10), yield load (Fy) e rigidez. RESULTADOS: Os valores médios de área de seção transversal do enxerto, F10, Fy, e rigidez não apresentaram diferenças significativas entre os grupos. CONCLUSÃO: A adição de um segundo dispositivo de fixação ligamentar tibial tipo agrafe, complementar ao parafuso de interferência, não aumentou a segurança mecânica do sistema.

5.
Full dent. sci ; 9(35): 34-39, 2018. tab, graf
Artigo em Português | BBO - Odontologia | ID: biblio-988320

RESUMO

O objetivo do estudo foi avaliar a alteração de temperatura nos ossos cortical e medular gerados pela resina acrílica na união dos transferentes por meio das redes de Bragg. Foram selecionados dois implantes cone morse Titamax (Neodent) 4 mm x 15 mm. Os implantes foram inseridos em um osso artificial da marca Sawbones, de acordo com as instruções do fabricante, cuja localização dos pilares foi referente aos dentes 44 e 46 com ausência do dente 45. Sobre os implantes foram instalados transferentes para a técnica aberta. Os transferentes foram esplintados por meio de um fio dental e aplicação de resina acrílica pela técnica de Nealon. Foram selecionadas duas resinas acrílicas: Duralay e GC Pattern LS. Dois sensores de fibra ótica foram posicionados, sendo um próximo à região cervical e outro na região apical do implante. Os sensores mensuraram a transferência de calor para o osso cortical e medular com o auxílio de uma pasta térmica (Implastec). Os dados foram submetidos à análise estatística por meio dos testes de normalidade de Shapiro-Wilk, ANOVA a dois critérios e teste de múltiplas comparações post hoc LSD (p<0,05). Foram encontradas diferenças significativas entre Duralay apical eGC Pattern LS cervical, GC Pattern LS cervical eGC Patternapical (p<0,05). As redes de Bragg apresentaram-se sensíveis para a mensuração da transferência de temperatura do transferente para os ossos cortical e medular. A partir dos resultados obtidos, pode-se afirmar que não há risco de necrose óssea (AU).


The purpose of the study was to evaluate the temperature change in the cortical and medullary bones generated by the acrylic resin in the union of transferents through the Bragg's grating. Two cone morse Titamax (Neodent) 4 mm x 15 mm implants were selected. The implants were inserted into a Sawbones artificial bone according to the manufacturer's instructions, abutment location were teeth 44 and 46 with absence of tooth 45. On the implants tranfers were installed for the open technique. The transfers were splined by means of a dental floss and acrylic resin application by the Nealon technique. Two acrylic resins were selected: Duralay and GC Pattern LS. Two fiber optic sensors were positioned, one near the cervical region and other at the implant apical region. The sensors measured the heat transfer to the cortical and medullary bones with the help of a thermal paste (Implastec). Data were submitted to statistical analysis using Shapiro-Wilk normality tests, two way ANOVA, and post hoc LSD multiple comparisons (p <0.05). Significant differences were found between Duralay apical and GC Pattern LS cervical, GC Pattern LS cervical and GC apical Pattern (p <0.05). The Bragg's grating were sensitive to temperature transference measurement from transfers to the cortical and medullary bones. From the results obtained, it is possible to ssure that there is no risk of bone necrosis (AU).


Assuntos
Resinas Acrílicas , Osso e Ossos , Implantes Dentários , Prótese Dentária Fixada por Implante , Alterações na Temperatura Corporal , Brasil , Análise de Variância , Interpretação Estatística de Dados , Tecnologia de Fibra Óptica/métodos
6.
Arq. odontol ; 53: 1-7, jan.-dez. 2017. tab
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-906069

RESUMO

Objetivo: O objetivo desse estudo foi avaliar e comparar as propriedades mecânicas dos cimentos resinosos duais convencionais e autoadesivos em macro e nanoescala. Métodos: Foram confeccionados 15 espécimes de cada marca de cimentos resinosos, AllCem (FGM), RelyX ARC (3M/ESPE) e RelyX U200 (3M/ESPE), para cada teste realizado (flexão de três pontos, compressão e nanoindentação) de acordo com as instruções dos fabricantes. Os espécimes foram fotoativados com aparelho Optilux Demetron (Kerr) por 40 segundos e armazenados em frascos escuros a 37ºC por 24 horas. Foram obtidos os resultados de resistência flexural, resistência à compressão, dureza e de módulo de Young para os diferentes testes mecânicos. Os dados foram avaliados pelos testes ANOVA, múltiplas comparações de Tukey HSD para análise dos valores de resistência, dureza e módulo de elasticidade entre os diferentes cimentos resinosos e ANOVA dois critérios e múltiplas comparações de Games Howell para análise dos módulos de Young entre os diferentes experimentos. Resultados: Os resultados revelaram que o AllCem obteve os maiores valores de resistência flexural e compressão axial (129±22,01 MPa; 243,71±29,75, respectivamente) e o RelyX U200 os menores valores (82,35±19,83 MPa; 134,57±48,93 MPa, respectivamente). Os valores de dureza não diferiram entre os cimentos estudados. No teste de flexão os valores de módulo de Young não diferiram entre os cimentos resinosos. No teste de compressão axial o AllCem apresentou módulo de Young estatisticamente maiores que dos demais cimentos. Para nanoindentação AllCem e RelyX U200 apresentaram maiores valores de módulo de Young que RelyX ARC. Os valores de módulo de Young diferiram significativamente entre todos os experimentos (p<0.05). Conclusão: Os valores das propriedades dos cimentos resinosos podem ser influenciados pelo tipo de experimento (macro- ou nanoescala) realizado.(AU)


Aim: The aim of this study was to evaluate and compare the mechanical properties of conventional and self-adhesive dual resin cements in macroscale and nanoscale. Methods: Fifteen specimens of each brand of resin cement ­ AllCem (FGM), RelyX ARC (3M/ ESPE), and RelyX U200 (3M/ESPE) ­ were made for each test performed in this study (three point bending, compression, and nanoindentation) according to the manufacturer's instructions. The specimens were photoactivated with Optilux Demetron (Kerr) for 40 seconds and stored in the dark at 37°C for 24 hours. Subsequently, they were submitted to flexural strength and axial compression tests at a speed of 1 mm/min, as well as to the Berkovich nanoindentation test. The results of flexural strength, compressive strength, hardness, and Young's modulus were obtained for the different mechanical tests. Data were evaluated by ANOVA tests; multiple comparisons of Tukey HSD to analyze the values of strength, hardness, and Young's modulus among the different resin cements; and ANOVA two criteria and multiple comparisons of Games Howell to analyze the Young's modulus within the different experiments. Results: The results showed that AllCem obtained the highest values of flexural strength and axial compression (129±22.01, 243.71±29.75 MPa, respectively), while RelyX U200 presented the lowest values (82.35 ± 19.83, 134.57 ± 48.93 MPa, respectively). The hardness values did not differ among the studied cements. In the flexural test, the Young's modulus values did not differ between the resin cements. In the axial compression test, AllCem presented a Young's modulus that was statistically higher than the other cements. In the nanoindentation test, AllCem and RelyX U200 presented higher values for Young's modulus than RelyX ARC. Young's modulus values differed significantly among all experiments (p <0.05). Conclusion: The values of resin cement properties can be influenced by the type of experiment (macroscale and nanoscale) performed.(AU)


Assuntos
Força Compressiva , Materiais Dentários , Testes de Dureza , Ciência dos Materiais , Cimentos de Resina/análise , Torção Mecânica , Resinas Sintéticas
7.
Full dent. sci ; 8(30): 69-73, 2017. ilus, tab
Artigo em Português | BBO - Odontologia | ID: biblio-909846

RESUMO

O presente estudo teve como objetivo avaliar a resistência coesiva e o módulo de elasticidade de cimentos resinosos à tração e compressão. Os 15 espécimes foram divididos em 3 grupos: G1: AllCem, G2: Rely X U100, G3: Rely X ARC e submetidos a dois testes mecânicos: tração e compressão. Foram obtidos os resultados de resistência e módulo de elasticidade à tração e compressão dos cimentos resinosos. Os resultados foram avaliados estatisticamente por meio da ANOVA e múltiplas comparações de Games-Howell. Para a tração, a ANOVA revelou diferenças significativas entre os valores médios segundo o cimento (p<0.05). O teste de múltiplas comparações de Games-Howell para a tensão de ruptura mostrou que o cimento resinoso Rely X U100 apresentou os menores valores (21.91 ± 4.97 MPa), seguido pelo AllCem (23.13 ± 5.51 MPa) e pelo Rely X ARC (36.10 ± 8.27 MPa), onde o Rely X ARC diferiu estatisticamente doRely X U100 e doAllCem. ORely X U100 e AllCemnão revelaram diferenças entre si (p<0.05). No teste de compressão, o cimento Rely X U100 também apresentou os menores valores (134.57 ± 48.93 MPa), seguido do Rely X ARC (145.64 ± 32.76 MPa) e AllCem (243.71 ± 29.75 MPa), onde os cimentos Rely X U100 e Rely X ARC diferiram estatisticamente do AllCem e não revelaram diferenças entre si (p<0.05). Concluiu-se que os cimentos resinosos duais convencionais estudados apresentaram maiores valores de resistência à tração quando comparados ao cimento resinoso dual autoadesivo. A resistência coesiva à compressão foi maior que à tração para todos os cimentos resinosos estudados (AU).


The aim of the present study was to evaluate the cohesive strength and elastic modulus of resin cements subjected to the tensile and compression strength. Fifteen specimens were divided into 3 groups: G1: Allcem, G2: Rely X U100, G3: Rely X ARC, and subjected to two mechanical testing: tensile and compression. Strength and elastic modulus results of tension and compression tests of resin cements were obtained. The results were statistically analyzed by ANOVA and multiple comparisons of Games-Howell. For tensile test, the ANOVA revealed significant differences between the mean values according to the cement (p <0.05). The test multiple Games-Howell comparisons for the break to tensile showed that the resin cement Rely X U100 showed the lowest values (21.91 ± 4.97 MPa), followed by Allcem (23:13 ± 5:51 MPa) and the Rely X ARC (36.10 ± 8.27 MPa ), where the Rely X ARC differed from Rely X U100 and Allcem. The Rely X U100 and Allcem revealed no differences (p<0.05). In the compression test, Rely X U100 cement also had the lowest values (134.57 ± 48.93 MPa), followed by Rely X ARC (145.64 ± 32.76 MPa) and Allcem (243.71 ± 29.75 MPa), where cement Rely X U100 and Rely X ARC differed from the Allcem and revealed no differences (p <0.05). It was concluded that conventional dual resin cements studied showed higher tensile strength when compared to the dual-cured self-adhesive cement. The cohesive compressive strength was greater than to tensile for all resin cements studied (AU).


Assuntos
Módulo de Elasticidade , Ciência dos Materiais/métodos , Cimentos de Resina , Resistência à Tração , Análise de Variância , Brasil
8.
Full dent. sci ; 7(25): 64-69, jan.2016. tab
Artigo em Português | LILACS | ID: lil-790080

RESUMO

O objetivo deste estudo foi avaliar a correlação entre as cores nomeadas com identificações iguais de dentes artificiais de resina acrílica de diferentes marcas comerciais. Foram selecionadas cinco marcas: Vipi Dent Plus (VIPI), Biolux OMC (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás) e Tritone (VIPI), todas utilizando o mesmo padrão de nomenclatura. De cada marca comercial foram utilizadas as cores: 60, 62, 65, 66, 67 e 69. Para realizar as comparações de cor foi utilizado o aparelho espectrofotômetro Vita Easy Shade. Após três medições de cada cor, foi obtida a média das leituras, todas realizadas no centro do dente, no mesmo horário e com fundo cinza claro padronizado. Assim, os valores de L*, a* e b* foram obtidos. Esses valores foram tabulados para cálculos do ∆E, onde ∆E< ou = 3 representa diferença de cor significativa e perceptível. Observou-se correlação entre as marcas comerciais na cor 60 Biocler GII e Natus Dent (ΔE= 3); Biocler GII e Tritone (ΔE= 2,87), cor 62 Biolux OMC e Natus Dent (ΔE=1,33), cor 67 Natus Dent e Tritone (ΔE=2,06) e Tritone e Vipi Dent Plus (ΔE=1,92). Concluiu-se que os resultados demonstraram poucas correlações entre as marcas avaliadas e as correlações existentes não ocorreram de forma igual para todas as cores, dificultando o sucesso dos tratamentos protéticos, assim como a comunicação entre o cirurgião dentista e o técnico em prótese dentária...


The objective of this study was to evaluate the correlation between colors of artificial acrylic resin teeth from different brands with the same name and identification. Five brands were selected: Vipi Dent Plus (VIPI), Biolux WTO (VIPI), Biocler G II (Dentbrás), Natus Dent (Dentbrás), and Tritone (VIPI), all using the same naming pattern. The used colors from each brand were: 60, 62, 65, 66, 67, and 69. To perform comparisons of color the Vita Easy Shade spectrophotometer was used. After three measurements of each color a mean was obtained All readings were performed on the central area of the tooth, at the same time and with clear standard gray background, obtaining the values of L*, a*, and b*. These values were tabulated for ΔE calculations, where ΔE < or = 3 represented significant and noticeable color difference. There is a correlation between the trademarks in color 60 Biocler GII and Natus Dent (ΔE = 3); Biocler GII and Tritone (ΔE = 2.87), color 62 Biolux WTO and Natus Dent (ΔE = 1.33), color 67 Natus Dent and Tritone (ΔE = 2.06), and Tritone and Vipi Dent Plus (ΔE = 1, 92). It was concluded that the results showed little correlation between the evaluated brands and correlation did not occur equally to all colors, hindering the success of prosthetic treatments as well as communication between the dental surgeon and dental technician...


Assuntos
Humanos , Espectrofotômetros/métodos , Prótese Dentária , Resinas Compostas/química , Dente Artificial , Cor
9.
Rev. bras. ortop ; 50(2): 131-135, Mar-Apr/2015. tab, graf
Artigo em Inglês | LILACS | ID: lil-748349

RESUMO

The aim of this study was to review all cases of pseudoaneurysm in the literature, in predominantly arthroscopic procedures on the knee, and to report on a case of pseudoaneurysm that we treated. A bibliographic search was conducted for scientific articles published in Brazilian and foreign periodicals over the last 23 years. Forty-seven cases were found, in 40 articles. In addition to these 47 cases, there was the case that we treated, which was also included in the data. Among the operations that progressed with formation of a pseudoaneurysm, 60% were cases of meniscal injuries and 23%, anterior cruciate ligament injuries. In 46% of the cases, the artery affected with the popliteal, and in 21%, the inferomedial genicular artery. The commonest clinical symptom was pain (37%), followed by pulsating tumor (31%), edema of the calf (12%) and hemarthrosis (11%). The median time taken to make the diagnosis was 11 days, but it ranged from one day to 10 weeks after the procedure. Although rare, pseudoaneurysms are a risk that is inherent to arthroscopic surgery. All patients should be made aware of the vascular risks, even in small-scale procedures.


O objetivo deste estudo é revisar na literatura todos os casos de pseudoaneurisma em procedimentos predominantemente artroscópicos do joelho e relatar um caso de pseudoaneurisma tratado pelos autores. Foi feita uma pesquisa bibliográfica por meio de artigos científicos publicados em periódicos nacionais e internacionais nos últimos 23 anos. Foram levantados 47 casos, em 40 artigos. Somou-se aos 47 um caso dos autores deste estudo que foi incluído nos dados. Das cirurgias que cursaram com pseudoaneurisma, 60% se tratavam de lesões meniscais e 23% de lesões do ligamento cruzado anterior. Em 46% dos casos a artéria acometida foi poplítea e em 21% a artéria genicular inferomedial. O sintoma clínico mais comum foi dor (37%), seguido de tumor pulsátil (31%), edema de panturrilha (12%) e hemartrose (11%). A mediana do tempo para diagnóstico foi de 11 dias, mas variou de um dia até 10 semanas após o procedimento. Apesar de raro, o pseudoaneurisma é um risco inerente à cirurgia artroscópica. Todo paciente deve ser notificado dos riscos vasculares, mesmo em procedimentos de pequeno porte.


O objetivo deste estudo é revisar na literatura todos os casos de pseudoaneurisma em procedimentos predominantemente artroscópicos do joelho e relatar um caso de pseudoaneurisma tratado pelos autores. Foi feita uma pesquisa bibliográfica por meio de artigos científicos publicados em periódicos nacionais e internacionais nos últimos 23 anos. Foram levantados 47 casos, em 40 artigos. Somou-se aos 47 um caso dos autores deste estudo que foi incluído nos dados. Das cirurgias que cursaram com pseudoaneurisma, 60% se tratavam de lesões meniscais e 23% de lesões do ligamento cruzado anterior. Em 46% dos casos a artéria acometida foi poplítea e em 21% a artéria genicular inferomedial. O sintoma clínico mais comum foi dor (37%), seguido de tumor pulsátil (31%), edema de panturrilha (12%) e hemartrose (11%). A mediana do tempo para diagnóstico foi de 11 dias, mas variou de um dia até 10 semanas após o procedimento. Apesar de raro, o pseudoaneurisma é um risco inerente à cirurgia artroscópica. Todo paciente deve ser notificado dos riscos vasculares, mesmo em procedimentos de pequeno porte.


Assuntos
Humanos , Masculino , Adulto Jovem , Falso Aneurisma , Ligamento Cruzado Anterior , Artérias , Artroscopia , Joelho
10.
Rev. bras. ortop ; 48(5): 417-420, Sept-Oct/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-697312

RESUMO

OBJECTIVE: To study the anatomy of the hamstring tendons insertion and anatomical rela-tionships. METHODS: Ten cadaver knees with medial and anterior intact structures were selected. The dissection was performed from anteromedial access to exposure of the insertion of the flexor tendons (FT), tibial plateau (TP) and tibial tuberosity (TT). A needle of 40 × 12 and a caliper were used to measure the distance of the tibial plateau of the knee flexor tendons insertion at 15 mm from the medial border of the patellar tendon and tibial tuberosity to the insertion of the flexor tendons of the knee. The angle between tibial plateau and the insertion of the flexor tendons of the knee (A-TP-FT) was calculated using Image Pro Plus software. RESULTS: The mean distance TP-FT was 41 ± 4.6 mm. The distance between the TT-FT was 6.88 ± 1 mm. The (A-TP-FT) was 20.3 ± 4.9°. CONCLUSION: In the anterior tibial flexor tendons are about 40 mm from the plateau with an average of 20°. .


OBJETIVO: Determinar parâmetros anatômicos para localizar a inserção dos tendões flexores do joelho na tíbia. MÉTODOS: Foram selecionados 10 joelhos de cadáveres com estruturas mediais e anteriores íntegras. A dissecção foi feita por acesso ânteromedial até a exposição adequada da inserção dos tendões flexores (TF), do planalto tibial (PT) e da tuberosidade anterior da tíbia (TAT). Uma agulha 40×12 e um paquímetro digital foram usados para aferir a distância do planalto tibial da inserção dos tendões flexores do joelho a 15 mm da borda medial ao tendão patelar e da tuberosidade anterior da tíbia à inserção dos tendões flexores do joelho. O ângulo o planalto tibial e a inserção dos tendões flexores do joelho (PT-TF) foi calculado com o auxílio do software ImagePro Plus(r). RESULTADOS: A distância PT-TF foi de 41 ± 4,6 mm em média. A distância entre a TAT-TF foi de 6,88 ± 1 mm. A angulação (PT-TF) foi de 20,3 ± 4,9 graus. CONCLUSÃO: Na região anterior da tíbia os tendões flexores estão a cerca de 40 mm do planalto com um ângulo médio de 20 graus. .


Assuntos
Humanos , Anatomia , Cadáver , Joelho/anatomia & histologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA