Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Oper Dent ; 46(5): 537-546, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34929042

RESUMO

The aim of this in vitro study was to quantitatively evaluate the internal gap of resin composites of high-and low-viscosity used in single- and incremental-fill techniques in Class I cavities exposed to thermal cycling (TC) using optical coherence tomography (OCT). Cavities of 4-mm depth and 3-mm diameter were prepared in 36 third molars randomly distributed into four groups, according to viscosity of restorative resin-based composite (high or low viscosity, all from 3M Oral Care) and technique application (bulk or incremental fill) used (n=9): RC, high-viscosity, incremental-fill, resin-based composite (Filtek Z350 XT Universal Restorative); BF, high-viscosity, bulk-fill, resin-based composite (Filtek One Bulk Fill); LRC, lowviscosity, incremental-fill, resin-based composite (Filtek Z350 XT Flowable Universal Restorative); and LBF, low-viscosity, bulk-fill, resin-based composite (Filtek Flowable Restorative). Single Bond Universal Adhesive system (3M Oral Care) was used in all the experimental groups. The incremental-fill technique was used for RC and LRC groups (2-mm increments), and a single-layer technique was used for BF and LBF groups, as recommended by the manufacturer. The internal adaptation of the resin at all dentin walls was evaluated before and after TC (5000 cycles between 5°C and 55°C) using OCT images. Five images of each restored tooth were obtained. Images were analyzed using ImageJ software that measured the entire length of the gaps at the dentin-restoration interface. The length of gaps (µm) was analyzed using two-way repeated measures ANOVA and the Tukey tests (α=0.05). There was a significant interaction between material types and TC (p=0.006), and a significant difference among all material types (p<0.0001), before and after TC (p<0.0001). Increased internal gaps at the dentin-restoration interface were noticed after TC for all groups. RC presented the lowest value of internal gap before and after TC, while LBF showed the highest values of internal gap after TC. In conclusion, TC negatively affected the integrity of internal gap, whereas high-viscosity, incremental-fill, resin-based composite presented better performance in terms of internal adaptation than low-viscosity, bulk-fill materials in Class I cavities.


Assuntos
Cárie Dentária , Restauração Dentária Permanente , Resinas Compostas/química , Resinas Compostas/uso terapêutico , Materiais Dentários/química , Restauração Dentária Permanente/métodos , Humanos , Teste de Materiais , Tomografia de Coerência Óptica , Viscosidade
2.
Analyst ; 146(6): 1973-1980, 2021 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-33502395

RESUMO

This work describes a new method for the analysis of handwritten documents through a system composed of a pre-selector optical analyser equipped with light sources of different wavelengths coupled with bandpass filters combined with an optical coherence tomography (OCT) instrument. The optical analyser identifies regions with different pen pressures on the paper using specific wavelengths from ultraviolet (UV) to infrared (IR) and bandpass filters. Then the selected regions are analysed with a coherence tomography analyser to measure the depth of grooves and capture three-dimensional images. With this methodology, it is possible to identify similarities, or differences, between the pieces of evidence under investigation, increasing the possibility of correct attribution concerning the authorship of the signature and we also showed that this feature is independent of the paper substrate. In this work, a new strategy will be presented to categorize and quantify pen pressure in order to aid a better response for a forensic examiner. Thereby, from the observed areas that display higher pressures (more significant grooves), it is possible to determine the authorship of the signature.

3.
Skin Res Technol ; 21(1): 90-3, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25066480

RESUMO

BACKGROUND/PURPOSE: When evaluating skin care products for human skin, quantitative test methods need to be simple, precise and reliable. Optical coherence tomography (OCT), provides high-resolution sectional images of translucent materials to a depth of a few millimeters, a technique usually applied to medical measurements in ophthalmology and dermatology. This study aimed to demonstrate the application of OCT as the main technique for monitoring changes in skin topography during tests of a wrinkle-reduction product in humans. METHODS: We used a commercial OCT apparatus to perform clinical examinations of skin roughness in treated and non-treated sites in the periorbital region of thirty human voluntaries who were using an anti-aging product commercially available: Natura Chronos® Flavonóides de Passiflora 45+ FPS15, from Natura Cosméticos, Brazil. Measurements were performed days 0, 7, 14 and 28 of treatment. Equipment and software allowed real-time recording of skin roughness parameters and wrinkle depths. RESULTS: The OCT measurements have allowed the monitoring of changes in skin roughness, which have shown reduction in treated sites around 10%. The obtained depth distributions also indicate reduction in the occurrence of wrinkles deeper than 170 µm. The verified results are consistent with those typically obtained after successful treatment with modern anti-aging products. CONCLUSION: By using the OCT technique, it was possible to quantify changes in skin roughness and in the distribution of depths of skin wrinkles, with adequate sensitivity. OCT imaging allows the direct visualization of the skin topography with resolution of micrometers, a reliable and interactive tool for clinical use. Therefore, for the first time, we demonstrated the use of OCT technique to verify the efficacy of cosmetic products in real time.


Assuntos
Envelhecimento da Pele/efeitos dos fármacos , Envelhecimento da Pele/fisiologia , Creme para a Pele/administração & dosagem , Pele/citologia , Pele/efeitos dos fármacos , Tomografia de Coerência Óptica/métodos , Administração Tópica , Adulto , Monitoramento de Medicamentos/métodos , Feminino , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Cell Tissue Bank ; 16(1): 47-53, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24322969

RESUMO

As banked human tissues are not widely available, the development of new non-destructive and contactless techniques to evaluate the quality of allografts before distribution for transplantation is very important. Also, tissues will be processed accordingly to standard procedures and to minimize disease transmission most tissue banks will include a decontamination or sterilization step such as ionizing radiation. In this work, we present a new method to evaluate the internal structure of frozen or glycerol-processed human cartilages, submitted to various dosis of irradiation, using the total optical attenuation coefficient retrieved from optical coherence tomography (OCT) images. Our results show a close relationship between tensile properties and the total optical attenuation coefficient of cartilages. Therefore, OCT associated with the total optical attenuation coefficient open a new window to evaluate quantitatively biological changes in processed tissues.


Assuntos
Cartilagem/fisiologia , Radiação Ionizante , Tomografia de Coerência Óptica/métodos , Cartilagem/efeitos da radiação , Humanos
5.
Cell Tissue Bank ; 15(3): 337-43, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23887800

RESUMO

As banked human tissues are not widely available, the development of new non-destructive and contactless techniques to evaluate the quality of allografts before distribution for transplantation is very important. Also, tissues will be processed accordingly to standard procedures and to minimize disease transmission most tissue banks will include a decontamination or sterilization step such as ionizing radiation. In this work, we present a new method to evaluate the internal structure of frozen or glycerol processed human cartilages, submitted to various dosis of irradiation, using the total optical attenuation coefficient retrieved from optical coherence tomography (OCT) images. Our results show a close relationship between tensile properties and the total optical attenuation coefficient of cartilages. Therefore, OCT associated with the total optical attenuation coefficient open a new window to evaluate quantitatively biological changes in processed tissues.


Assuntos
Cartilagem/diagnóstico por imagem , Cartilagem/patologia , Estresse Mecânico , Tomografia de Coerência Óptica , Aloenxertos/patologia , Fenômenos Biomecânicos , Cadáver , Feminino , Humanos , Masculino , Radiação Ionizante , Radiografia
6.
J Biomed Opt ; 10(6): 064027, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16409092

RESUMO

Evaluation of molar dental restorations on enamel is performed using optical coherence tomography (OCT) with 10 microm resolution. Images of approximately 50 microm failure gaps in the restorations are demonstrated and the OCT images are compared with x-ray and optical microscopy pictures. The results demonstrate the potential of the technique for clinical evaluation of dental restorations.


Assuntos
Esmalte Dentário/patologia , Esmalte Dentário/cirurgia , Desgaste de Restauração Dentária , Análise de Falha de Equipamento/métodos , Interpretação de Imagem Assistida por Computador/métodos , Dente Molar/patologia , Dente Molar/cirurgia , Algoritmos , Diagnóstico Bucal/métodos , Estudos de Viabilidade , Humanos , Técnicas In Vitro , Prognóstico , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA