Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Bioinformatics ; 21(1): 376, 2020 Aug 31.
Artigo em Inglês | MEDLINE | ID: mdl-32867673

RESUMO

BACKGROUND: Two-dimensional gel electrophoresis (2-DGE) is a commonly used tool for proteomic analysis. This gel-based technique separates proteins in a sample according to their isoelectric point and molecular weight. 2-DGE images often present anomalies due to the acquisition process, such as: diffuse and overlapping spots, and background noise. This study proposes a joint pre-processing framework that combines the capabilities of nonlinear filtering, background correction and image normalization techniques for pre-processing 2-DGE images. Among the most important, joint nonlinear diffusion filtering, adaptive piecewise histogram equalization and multilevel thresholding were evaluated using both synthetic data and real 2-DGE images. RESULTS: An improvement of up to 46% in spot detection efficiency was achieved for synthetic data using the proposed framework compared to implementing a single technique of either normalization, background correction or filtering. Additionally, the proposed framework increased the detection of low abundance spots by 20% for synthetic data compared to a normalization technique, and increased the background estimation by 67% compared to a background correction technique. In terms of real data, the joint pre-processing framework reduced the false positives up to 93%. CONCLUSIONS: The proposed joint pre-processing framework outperforms results achieved with a single approach. The best structure was obtained with the ordered combination of adaptive piecewise histogram equalization for image normalization, geometric nonlinear diffusion (GNDF) for filtering, and multilevel thresholding for background correction.


Assuntos
Eletroforese em Gel Bidimensional/métodos , Bases de Dados de Proteínas , Humanos , Processamento de Imagem Assistida por Computador , Proteínas/análise , Proteômica/métodos , Razão Sinal-Ruído
2.
Genomics Proteomics Bioinformatics ; 16(1): 63-72, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29474888

RESUMO

Various methods and specialized software programs are available for processing two-dimensional gel electrophoresis (2-DGE) images. However, due to the anomalies present in these images, a reliable, automated, and highly reproducible system for 2-DGE image analysis has still not been achieved. The most common anomalies found in 2-DGE images include vertical and horizontal streaking, fuzzy spots, and background noise, which greatly complicate computational analysis. In this paper, we review the preprocessing techniques applied to 2-DGE images for noise reduction, intensity normalization, and background correction. We also present a quantitative comparison of non-linear filtering techniques applied to synthetic gel images, through analyzing the performance of the filters under specific conditions. Synthetic proteins were modeled into a two-dimensional Gaussian distribution with adjustable parameters for changing the size, intensity, and degradation. Three types of noise were added to the images: Gaussian, Rayleigh, and exponential, with signal-to-noise ratios (SNRs) ranging 8-20 decibels (dB). We compared the performance of wavelet, contourlet, total variation (TV), and wavelet-total variation (WTTV) techniques using parameters SNR and spot efficiency. In terms of spot efficiency, contourlet and TV were more sensitive to noise than wavelet and WTTV. Wavelet worked the best for images with SNR ranging 10-20 dB, whereas WTTV performed better with high noise levels. Wavelet also presented the best performance with any level of Gaussian noise and low levels (20-14 dB) of Rayleigh and exponential noise in terms of SNR. Finally, the performance of the non-linear filtering techniques was evaluated using a real 2-DGE image with previously identified proteins marked. Wavelet achieved the best detection rate for the real image.


Assuntos
Algoritmos , Eletroforese em Gel Bidimensional/métodos , Processamento de Imagem Assistida por Computador/métodos , Proteínas/análise , Proteômica/métodos , Software , Animais , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA