Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Lasers Med Sci ; 32(1): 161-167, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27778115

RESUMO

The aim of this study was to evaluate the effects of dentin thickness and pulpal pressure simulation (PPS) on the variation of intrapulpal temperature (∆T) when submitted to an adhesive technique using laser irradiation. Sixty sound human molars were sectioned and randomly divided into two groups (n = 30): group 1-1 mm of dentin thickness; group 2-2 mm of dentin thickness. Each group was divided into two subgroups (n = 15): subgroup A-absence of PPS; subgroup P-presence of PPS (15 cm H2O), sequentially treated with the following: 37 % phosphoric acid, adhesive system (Adper Single Bond), irradiation with Nd:YAG laser (1064 nm, 10 Hz, 60 s) using 60, 80, and 100 mJ/pulse energy parameters and light-curing (10 s). The ∆T was evaluated during the laser irradiation with a digital thermometer. Data were analyzed by three-way ANOVA and Tukey tests (p < 0.05). Three-way ANOVA revealed no significant differences for dentin thickness (p = 0.6512) on ∆T. PPS significantly reduced ∆T (p = 0.0001). The laser energy parameters (p = 0.0027) indicated that 100 mJ presented with significantly greater ∆T when compared to the groups irradiated with 80 and 60 mJ. Dentin thickness did not affect ∆T. The presence of PPS reduced the mean temperature values. The Nd:YAG laser energy parameters had a negative influence on the variation of temperature in the absence of PPS. In the presence of PPS, there was no risk to the pulp, since this study obtained temperature increases below 5.5 °C for all energy parameters, showing the technical viability for in vivo conditions.


Assuntos
Polpa Dentária/fisiologia , Dentina/química , Dentina/efeitos da radiação , Lasers de Estado Sólido , Pressão , Temperatura , Análise de Variância , Polpa Dentária/efeitos da radiação , Humanos
2.
Lasers Med Sci ; 31(1): 49-56, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26510575

RESUMO

The aim of this study was to evaluate the effects of simulated pulpal pressure (SPP) on the variation of intrapulpal temperature (ΔT) and microtensile bond strength (µTBS) to dentin submitted to an adhesive technique using laser irradiation. One hundred sound human molars were randomly divided into two groups (n = 50), according to the presence or absence of SPP (15 cm H2O). Each group was divided into five subgroups (n = 10) according to Nd:YAG laser energy (60, 80, 100, 120, 140 mJ/pulse). The samples were sequentially treated with the following: 37 % phosphoric acid, adhesive (Scotchbond Universal), irradiation with Nd:YAG laser (60 s), and light curing (10 s). ΔT was evaluated during laser irradiation using a type K thermocouple. Next, a composite resin block was build up onto the irradiated area. After 48 h, samples were submitted to microtensile test (10 kgf load cell, 0.5 mm/min). Data were analyzed by two-way ANOVA and Tukey tests (p = 0.05). ANOVA revealed significant differences for ΔT and TBS in the presence of SPP. For ΔT, the highest mean (14.3 ± 3.23 °C)(A) was observed in 140 mJ and without SPP. For µTBS, the highest mean (33.4 ± 4.15 MPa)(A) was observed in 140 mJ and without SPP. SPP significantly reduced both ΔT and µTBS during adhesive procedures, lower laser energy parameters resulted in smaller ΔT, and the laser parameters did not influence the µTBS values.


Assuntos
Polpa Dentária , Dentina/química , Dentina/efeitos da radiação , Lasers de Estado Sólido , Pressão , Temperatura , Adesividade , Resinas Compostas/química , Lâmpadas de Polimerização Dentária , Humanos , Resistência à Tração
3.
Oper Dent ; 38(4): 447-55, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23215546

RESUMO

PURPOSE: The aim of this study was to investigate the influence of Nd:YAG laser on the shear bond strength to enamel and dentin of total and self-etch adhesives when the laser was applied over the adhesives, before they were photopolymerized, in an attempt to create a new bonding layer by dentin-adhesive melting. MATERIAL AND METHODS: One-hundred twenty bovine incisors were ground to obtain flat surfaces. Specimens were divided into two substrate groups (n=60): substrate E (enamel) and substrate D (dentin). Each substrate group was subdivided into four groups (n=15), according to the surface treatment accomplished: X (Xeno III self-etching adhesive, control), XL (Xeno III + laser Nd:YAG irradiation at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental), S (acid etching + Single Bond conventional adhesive, Control), and SL (acid etching + Single Bond + laser Nd:YAG at 140 mJ/10 Hz for 60 seconds + photopolymerization, experimental). The bonding area was delimited with 3-mm-diameter adhesive tape for the bonding procedures. Cylinders of composite were fabricated on the bonding area using a Teflon matrix. The teeth were stored in water at 37°C/48 h and submitted to shear testing at a crosshead speed of 0.5 mm/min in a universal testing machine. Results were analyzed with three-way analysis of variance (ANOVA; substrate, adhesive, and treatment) and Tukey tests (α=0.05). ANOVA revealed significant differences for the substrate, adhesive system, and type of treatment: lased or unlased (p<0.05). The mean shear bond strength values (MPa) for the enamel groups were X=20.2 ± 5.61, XL=23.6 ± 4.92, S=20.8 ± 4.55, SL=22.1 ± 5.14 and for the dentin groups were X=14.1 ± 7.51, XL=22.2 ± 6.45, S=11.2 ± 5.77, SL=15.9 ± 3.61. For dentin, Xeno III self-etch adhesive showed significantly higher shear bond strength compared with Single Bond total-etch adhesive; Nd:YAG laser irradiation showed significantly higher shear bond strength compared with control (unlased). CONCLUSION: Nd:YAG laser application prior to photopolymerization of adhesive systems significantly increased the bond strength to dentin.


Assuntos
Colagem Dentária , Esmalte Dentário/ultraestrutura , Adesivos Dentinários/efeitos da radiação , Dentina/ultraestrutura , Lasers de Estado Sólido , Condicionamento Ácido do Dente/métodos , Animais , Bis-Fenol A-Glicidil Metacrilato/química , Bis-Fenol A-Glicidil Metacrilato/efeitos da radiação , Bovinos , Resinas Compostas/química , Materiais Dentários/química , Análise do Estresse Dentário/instrumentação , Adesivos Dentinários/química , Cura Luminosa de Adesivos Dentários/instrumentação , Cura Luminosa de Adesivos Dentários/métodos , Teste de Materiais , Ácidos Fosfóricos/química , Polimerização , Doses de Radiação , Resistência ao Cisalhamento , Estresse Mecânico , Temperatura , Fatores de Tempo , Água/química
4.
Int Endod J ; 41(6): 485-92, 2008 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-18422585

RESUMO

AIM: To evaluate ex vivo effectiveness of the three formulations of bleaching materials for intracoronal bleaching of root filled teeth using the walking bleach technique. METHODOLOGY: Extracted premolar teeth were stained artificially with human blood. After biomechanical preparation, the root canals were filled and a 3-mm thick intermediate base of zinc phosphate cement was placed at the level of the cementoenamel junction. The teeth were divided into four groups (n = 12): C (control, without bleaching material), A1 (sodium perborate + distilled water), A2 (sodium perborate + 10% carbamide peroxide) and A3 (sodium perborate + 35% carbamide peroxide). The bleaching materials were changed at 7 and 14 days. Evaluation of shade was undertaken with aid of the VITA Easyshadetrade mark (DeltaE*ab) and was performed after tooth staining and at 7, 14 and 21 days after bleaching, based on the CIELAB system. Data were analysed by anova for repeated measurements, Tukey and Dunnett tests (alpha = 0.05). RESULTS: The Tukey test revealed that group A1 (10.58 +/- 4.83 DeltaE*ab) was statistically different from the others (A2, 19.57 +/- 4.72 DeltaE*ab and A3, 17.58 +/- 3.33 DeltaE*ab), which were not different from each other. At 7 days: A1 was significantly different from A2; at 14 and 21 days: A2 and A3 were significantly better than A1; the Dunnett test revealed that the control group was different from A1, A2 and A3 at all periods (P < 0.05). CONCLUSION: Sodium perborate associated with both 10% and 35% carbamide peroxide was more effective than when associated with distilled water.


Assuntos
Manchas de Sangue , Cavidade Pulpar/efeitos dos fármacos , Peróxido de Hidrogênio , Tratamento do Canal Radicular/métodos , Clareamento Dental/métodos , Descoloração de Dente/tratamento farmacológico , Análise de Variância , Dente Pré-Molar , Boratos/uso terapêutico , Peróxido de Carbamida , Permeabilidade da Dentina/efeitos dos fármacos , Combinação de Medicamentos , Humanos , Peróxido de Hidrogênio/uso terapêutico , Técnicas In Vitro , Estudos Longitudinais , Peróxidos/uso terapêutico , Materiais Restauradores do Canal Radicular/efeitos adversos , Obturação do Canal Radicular/métodos , Estatísticas não Paramétricas , Fatores de Tempo , Descoloração de Dente/etiologia , Dente não Vital/terapia , Ureia/análogos & derivados , Ureia/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA