Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Esthet Restor Dent ; 2024 Aug 02.
Artigo em Inglês | MEDLINE | ID: mdl-39095320

RESUMO

OBJECTIVE: To evaluate the fracture behavior of human molars with extensive MOD restorations using short-fiber-reinforced resin composite of varying viscosities. MATERIALS AND METHODS: Human molars were randomly divided into seven groups (n = 12): intact teeth (control); restoration using conventional high-viscosity resin composite without (Filtek Z350XT, 3M) or with fibers (everX Posterior, GC); conventional low-viscosity resin composite without (Filtek Supreme Flowable, 3M) or with fibers (everX Flow Dentin Shade, GC); bulk-fill low-viscosity resin composite (Filtek Bulk Fill Flow, 3M) or with fibers (everX Flow Bulk Shade, GC). Restorations were performed on extensive MOD preparations, following the manufacturers' recommendations for each material. Specimens underwent fracture strength testing (N) and fracture pattern (%) categorized as repairable, possibly repairable, or non-repairable. Results were analyzed using a generalized linear model (N) and Fisher's exact test (%), with α = 0.05. RESULTS: Restorations performed with high-viscosity materials showed fracture strength values similar to the control and higher than those of restorations using low-viscosity resin composites (p < 0.0001), except for the bulk-fill low-viscosity resin composite with fibers (p > 0.05). Teeth restored using low-viscosity resin composite with fibers showed a higher % of repairable and possibly repairable fractures than the control (p = 0.0091). CONCLUSIONS: The viscosity of materials mediated the fracture strength, with restorations using high-viscosity resin composites promoting values similar to the intact tooth; however, the presence of fibers influenced the fracture pattern. CLINICAL SIGNIFICANCE: Teeth with MOD cavities restored with high-viscosity resin composites showed similar fracture strength to intact teeth. Fiber-reinforced low-viscosity resin composite for the base of restoration resulted in a more repairable/possibly repairable fracture pattern.

2.
Braz Oral Res ; 38: e030, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38597548

RESUMO

This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 µm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.


Assuntos
Resinas Compostas , Cárie Dentária , Humanos , Dureza , Microtomografia por Raio-X , Espectroscopia de Infravermelho com Transformada de Fourier , Teste de Materiais , Polimerização , Propriedades de Superfície , Materiais Dentários
3.
J Esthet Restor Dent ; 36(2): 381-390, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37676053

RESUMO

PURPOSE: To evaluate the reliability and failure modes of ultrathin (0.5 mm) lithium disilicate, translucent and ultra-translucent zirconia crowns for posterior teeth restorations. MATERIALS AND METHODS: Fifty-four mandibular first molar crowns of three ceramic materials: (1) Lithium disilicate (e.max CAD, Ivoclar Vivadent), (2) 3Y-TZP (Zirconn Translucent, Vipi), and (3) 5Y-PSZ (Cercon XT, Dentsply Sirona), with 0.5 mm of thickness were milled and cemented onto composite resin abutments. Eighteen samples of each group were tested under mouth-motion step-stress accelerated life testing in a humid environment using mild, moderate, and aggressive profiles. Data was subjected to Weibull statistics. Use level curves were plotted and reliability was calculated for a given mission of 100,000 cycles at 100, 200, and 300 N. Fractographic analyses of representative samples were performed in scanning electron microscope. RESULTS: Beta (ß) values suggest that failures were dictated by material's strength for lithium disilicate and by fatigue damage accumulation for both zirconias. No significant differences were detected in Weibull modulus and characteristic strength among groups. At a given mission of 100,000 cycles at 100 N, lithium disilicate presented higher reliability (98% CB: 95-99) regarding 3Y-TZP and 5Y-PSZ groups (84% CB: 65%-93% and 79% CB: 37&-94%, respectively). At 200 N, lithium disilicate reliability (82% CB: 66%-91%) was higher than 5Y-PSZ (20% CB: 4%-44%) and not significantly different from 3Y-TZP (54% CB: 32%-72%). Furthermore, at 300 N no significant differences in reliability were detected among groups, with a notable reduction in the reliability of all materials. Fractographic analyses showed that crack initiated at the interface between the composite core and the ceramic crowns due to tensile stress generated at the intaglio surface. CONCLUSIONS: Ultrathin lithium disilicate crowns demonstrated higher reliability relative to zirconia crowns at functional loads. Lithium disilicate and zirconia crown's reliability decreased significantly for missions at higher loads and similar failure modes were observed regardless of crown material. The indication of 0.5 mm thickness crowns in high-load bearing regions must be carefully evaluated. CLINICAL SIGNIFICANCE: Ultraconservative lithium disilicate and zirconia crowns of 0.5 mm thickness may be indicated in anterior restorations and pre-molars. Their clinical indication in high-load requirement regions must be carefully evaluated.


Assuntos
Coroas , Porcelana Dentária , Reprodutibilidade dos Testes , Teste de Materiais , Cerâmica , Zircônio , Análise do Estresse Dentário , Falha de Restauração Dentária , Desenho Assistido por Computador
4.
Braz. oral res. (Online) ; 38: e030, 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1557363

RESUMO

Abstract This study aimed to evaluate volumetric polymerization shrinkage, degree of conversion and Vickers hardness of four bulk-fill resin composites light-activated with their dedicated light curing units (LCUs). Four groups were evaluated, according to the type of composite and curing mode: Tetric EvoCeram Bulk-fill (TEBO) and Tetric EvoFlow Bulk-fill (TEBF) were light-activated with Bluephase Style 20i (20s, in high-mode), while Tetric Powerfill (TEPO) and Tetric Powerflow (TEPF) were light-activated with Bluephase PowerCure (3s). Volumetric polymerization shrinkage test (n = 6) was performed in standardized box-shaped class-I cavities of extracted third molars (4 x 4 x 4 mm). Teeth were scanned before and after resin composite application by micro-computed tomography, and acquired data were evaluated with Amira software. Degree of conversion (n = 5) was evaluated at the top and bottom surfaces of composite cylindric samples (4 mm diameter, 4 mm thickness) using an FT-IR spectrometer (spectra between 1,500 and 1,800 cm-1, 40 scans at a resolution of 4 cm-1). Three Vickers indentations (50 g / 15 s), spaced 500 μm apart, were performed on the top and bottom composite surfaces and averaged. One-way ANOVA was used for data evaluation. TEPF showed the lowest volumetric polymerization shrinkage (p < 0.05), while the other composites were not significantly different within each other (p > 0.05). All materials presented a significant decrease in degree of conversion and Vickers hardness when compared top to bottom surfaces (p < 0.05). Bottom to top surface ratios for degree of conversion ranged from 0.8 (TEBO and TEPO) to 0.9 (TEBF and TEPF), and from 0.4 (TEPO) to 0.7 (TEBF and TEPF) for hardness. In conclusion, resinous materials present a decrease in hardness and degree of conversion from top to bottom even when a higher power is used, while the flowable material TEPF showed the lowest volumetric shrinkage values compared to the other materials.

5.
J Mech Behav Biomed Mater ; 126: 105019, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34875501

RESUMO

PURPOSE: This study evaluated the effect of different tightening protocols on the probability of survival of screw-retained implant-supported anterior crowns. MATERIALS AND METHODS: Seventy-two implants with internal conical connections (4.0 × 10mm, Ti-6Al-4V, Colosso, Emfils) were divided into four groups (n = 18 each): 1) Manufacturer's recommendations torque (25 N.cm for abutment's screw and 30 N.cm for crown's screw) (MaT); 2) Retightening after 10 min (ReT); 3) Torque 16% below recommended to simulate an uncalibrated wrench (AgT), and; 4) Temporary crown simulation (TeT), where crowns were torqued to 13 N.cm to simulate manual tightening, subjected to 11,200 cycles to simulate temporary crown treatment time (190 N), and then retightened to manufacturer torque (TeT). All specimens were subjected to cyclic fatigue in distilled water with a load of 190 N until 250,000 cycles or failure. The probability of survival (reliability) to complete a mission of 50,000 cycles was calculated and plotted using the Weibull 2-Parameter analysis. Weibull modulus and number of cycles at which 62.3% of the specimens would fail were also calculated and plotted. The failure mode was characterized in stereo and scanning electron microscopes (SEM). RESULTS: The probability of survival was 69.3% for MaT, 70% for ReT, 54.8% for AgT, and 40.3% for TeT, all with no statistically significant difference. Weibull modulus was approximately 1.0 for all groups. The characteristic number of cycles for failure was 105,000 cycles for MaT, 123,000 for ReT, 82,000 cycles for AgT, and 54,900 cycles for TeT, with no significant difference between groups. The chief failure mode for MaT, ReT, AgT groups was crown screw fracture, whereas abutment screw fracture was the chief failure mode for the TeT group. CONCLUSION: Tightening protocol did not influence the probability of survival of the screw-retained anterior crowns supported by internal conical implants (Ti-6Al-4V, Colosso, Emfils).


Assuntos
Coroas , Implantes Dentários , Parafusos Ósseos , Falha de Restauração Dentária , Análise do Estresse Dentário , Probabilidade , Reprodutibilidade dos Testes , Torque
6.
Clin Oral Investig ; 26(3): 2635-2643, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34697656

RESUMO

OBJECTIVES: This study aims to evaluate the opalescence (OP) and color stability of composite resins over a period of 180 days and to compare composite resins' OP with enamel's OP. MATERIALS AND METHODS: Twenty human enamel specimens (5.0 × 0.3 mm) and 9 specimens (10.0 × 1.0 mm) of 10 colors of 4 different composite resins (3 M ESPE, FGM, Ivoclar-Vivadent, Miscerium) and one brand of adhesive (3 M ESPE) were made. The results were obtained by measuring the reflectance and transmittance spectra in the visible region. After baseline measurement, composites and adhesive were analyzed after 2, 7, 30, 60, 120, and 180 days. The Lab color coordinates were used in the calculations of the OP parameter and color differences in the CIELab and CIEDE2000 methods. The data were analyzed statistically. RESULTS: The materials tested showed variation and an increase in OP over time. The OP found for enamel was 18.06 ± 2.99, and some resins showed higher results. There was a strong correlation between the coordinate b*T and the OP over time. Enamel Plus was the only one material that presented no color changes during all periods in both color analyses. Filtek Z350 XT, AT, and BT did not show differences in any time when analyzed by CIELAB. CONCLUSIONS: The OP of most composite resins changed during the period of 180 days and was different from the OP of tooth enamel. In general, composites demonstrated small color changes over the period tested, being this characteristic material dependent. CLINICAL RELEVANCE: Natural teeth present different optical properties. Composite resins restorations should present properties similar to natural teeth and it is important that characteristics like color and opalescence remain stable over time.


Assuntos
Resinas Compostas , Iridescência , Cor , Esmalte Dentário , Humanos , Estudos Longitudinais , Teste de Materiais
7.
J Prosthet Dent ; 128(4): 784-792, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33741142

RESUMO

STATEMENT OF PROBLEM: The light source stability of digital cameras and smartphones is important in shade matching in restorative and prosthetic dentistry to communicate objectively with the dental laboratory. Techniques that standardize the light source of such devices are lacking, and this limitation can lead to color mismatches, difficulties in color communication, and treatment documentation. PURPOSE: The purpose of this clinical study was to compare the magnitude of color difference (ΔE) among 3 shade selection methods during the fabrication of ceramic crowns: visual shade selection with a shade guide, digital shade selection with a digital camera and cross-polarizing filter, and digital shade selection with a smartphone and a light-correcting device. MATERIAL AND METHODS: Forty-five patients in need of ceramic crowns were enrolled, and shade selection was evaluated according to different protocols: visual shade selection (A-D shade guide and IPS Natural Die Material Shade Guide, sent to the dental laboratory technician via a laboratory prescription); digital shade selection with a digital camera (D7000; Nikon Corp) with an 85-mm lens and wireless close-up flash, with and without a cross-polarizing filter (Polar eyes); and digital shade selection with a smartphone and a light-correcting device (iPhone XS attached to Smile Lite MDP, with and without its cross-polarizing filter accessory). Information from the smartphone was imported to an app (IPS e.max Shade Navigation App; Ivoclar AG) that converted the reading to a shade and level of translucency for the ceramic restoration. For all photographs, a gray reference card with known color values was positioned by the mandibular teeth and was used for white balancing of the digital photographs with a software program. All photographs were edited and sent to the dental laboratory: white-balanced with the shade guide; white-balanced with the substrate shade guide; black and white; saturated; and cross-polarized. Ceramic crowns were made with the same lithium disilicate material (IPS e.max CAD; Ivoclar AG) and cemented with the same resin cement (RelyX Ultimate Clicker, A3 shade; 3M). The ΔE values between the crown and the adjacent tooth were determined. The data were analyzed by using a 1-way analysis of variance (ANOVA) and Tukey post hoc tests (α=.05). RESULTS: The mean ΔE between a cemented ceramic crown and the adjacent tooth in the visual shade selection group was 5.32, significantly different than both digital camera (ΔE=2.75; P=.002) and smartphone (ΔE=2.34; P=.001), which were not different from each other (P=.857). CONCLUSIONS: The digital shade selection with photographs acquired with both a digital camera and a smartphone with a light-correcting device showed a threshold within the acceptable values (ΔE<3.7), whereas the visual shade selection showed an average ΔE above the threshold for acceptable values (ΔE>3.7). The use of a gray reference card helped standardize the white balance from the digital images.


Assuntos
Porcelana Dentária , Smartphone , Humanos , Cor , Coroas , Cimentos de Resina , Cerâmica
8.
J Esthet Restor Dent ; 33(5): 713-719, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33881792

RESUMO

OBJECTIVES: To evaluate the effect of atmospheric pressure plasma (PLA), sandblasting (SAN), silanization (SIL) and hydrophobic bonding resin (HBR) on the micro-shear bond strength (MSBS) of fresh nanofilled (NF) or microhybrid (MH) composites to water-aged nanofilled composite. MATERIALS AND METHODS: NF plates were fabricated and stored in distilled water for 4 months. The aged plates were assigned to the groups (n = 6): 1- untreated; 2- SAN + SIL + HBR; 3- HBR; 4- PLA + HBR; 5- SAN + HBR; 6- SAN + PLA + HBR; and 7- PLA. Two fresh composite cylinders were constructed on each plate with NF or MH composites and tested after 24 h or 1 year of water-storage, using the MSBS testing. Data were analyzed by three-way ANOVA and Tukey test (α = 0.05). RESULTS: NF yielded better outcomes than MH at 24 h, which was not observed at 1 year. HBR showed the highest MSBS results, while untreated and PLA groups yielded the lowest one. MSBS reduced for all groups after 1 year. CONCLUSIONS: Only HBR can obtain good MSBS results, while PLA alone was not beneficial. After 1 year, a reduction in repair MSBS was observed and the type of composite did not influence the results. CLINICAL RELEVANCE: The repair technique can be simplified with the use of only an adhesive and macromechanical retentions in the old composite, regardless the type of fresh composite.


Assuntos
Colagem Dentária , Gases em Plasma , Argônio , Resinas Compostas , Análise do Estresse Dentário , Teste de Materiais , Cimentos de Resina , Propriedades de Superfície
9.
J Esthet Restor Dent ; 33(3): 487-495, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32937028

RESUMO

OBJECTIVE: To evaluate, through microcomputed tomography (µCT), the cement film thickness of veneers and crowns made with different provisional materials. MATERIAL AND METHODS: A veneer and a crown preparation were performed on a central incisor and a second molar of a dental model, respectively, scanned with an intraoral scanner, and the .stl files were exported to an LCD-based SLA three-dimensional (3D)-Printer. Twenty-four preparations were 3D-printed for each veneer and crown and divided into four groups (n = 6/group): (a) Acrylic resin (Acrílico Marche); (b) Bisacrylic resin (Protemp 4); (c) PMMA computer-aided design and computer-aided manufacturing (CAD-CAM) (Vipiblock); and (d) 3D-printed resin for provisional restorations (Raydent C&B for temporary crown and bridge). Veneers and crowns restorations were performed and cemented with a flowable composite. Each specimen was scanned with a µCT apparatus, files were imported for data analysis, and cement film thickness was quantitatively measured. Data were analyzed by 2-way ANOVA and Tukey post-hoc tests (α = .05). RESULTS: Crowns presented a thicker cementation film than veneers (P < .05).The bisacrylic resin showed the smallest veneer film thickness, similar to the acrylic resin (P = .151), which was not significantly different than the PMMA CAD/CAM material (P = .153). The 3D printed provisional material showed the thicker film, different than all other materials (P < .05). The bisacrylic resin showed a cement film thickness with a high number of voids in its surface. For crowns cementation, the 3D printed provisional material showed the thicker cementation film, different than all other materials (P < .05). CONCLUSIONS: Different provisional materials present different film thicknesses. The 3D printed provisional material showed the highest veneer and crown film thicknesses. Veneers film thicknesses were smaller than crowns for all provisional materials. CLINICAL SIGNIFICANCE: The 3D printed provisional material studied can be satisfactorily used, presenting appropriate adaptation with the tooth preparation, however, it shows the highest cement film thickness for both veneers and crowns cementations when compared with other provisional materials. A better internal fit, or smaller cement film thickness is obtained by CAD/CAM materials, acrylic and bisacrylic resins. Veneer cementation showed a smaller cement film thickness compared with crown cementation for all provisional materials.


Assuntos
Coroas , Porcelana Dentária , Desenho Assistido por Computador , Materiais Dentários , Planejamento de Prótese Dentária , Teste de Materiais , Impressão Tridimensional , Cimentos de Resina , Microtomografia por Raio-X
10.
J Esthet Restor Dent ; 33(2): 269-276, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32989879

RESUMO

OBJECTIVE: To evaluate color matching of universal composite restorations performed in anterior teeth using two evaluation methods. MATERIALS AND METHODS: Sixty class III preparations were made on denture central incisors with different shades (A1-A3) and restored with multishade (Tetric Evoceram, Filtek Universal, and TPH Spectra Universal) and single-shade (Omnichroma) universal composites (n = 5). For photographic analysis, a digital photograph of each specimen was taken under standardized set-up. Color measurements were taken in the center of the restoration, and in the tooth surface 1.0 mm adjacent from the tooth/restoration margin. CIELab coordinates were recorded and color difference analysis (ΔE) was made using the CIEDE-2000 formula. For visual analysis, calibrated observers performed visual scoring of color matching and differences were graded as 0:excellent match; 1:very good match; 2:not so good match; 3:obvious mismatch; 4:huge mismatch. All data were statistically analyzed using a linear mixed model analysis with a confidence interval of 95%. RESULTS: For photographic analysis, Omnichroma showed the highest ΔE compared to the other composites for all shades (P < .05), without difference among experimental groups regarding tooth shade. For visual analysis, Omnichroma showed the highest scores (P < .05) for all teeth shades, without differences between the other groups. Furthermore, there were no differences between visual scores for different shades of a same resin composite group. CONCLUSIONS: Multishade universal composites presented higher color matching than the single shade universal composite. There were no differences of color matching for different tooth shades for all composites. CLINICAL SIGNIFICANCE: Universal composites with increased color matching may be helpful to simplify anterior restorations, minimizing clinical errors.


Assuntos
Restauração Dentária Permanente , Dente , Cor , Resinas Compostas , Teste de Materiais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA