Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Cardiol Res ; 14(4): 291-301, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37559713

RESUMO

Background: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. Methods: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. Results: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs. 5.95%, P = 0.17). Late ST was observed in 1.19% cases of the XIENCE arm, while there were no such cases in the BioMime arm (P = 0.16). Conclusions: The objective comparisons between the novel BP-based BioMime SES and the well-established DP-based XIENCE EES in this randomized controlled trial show acceptable outcomes of both the devices in the cardiac deaths, MI, ID-TVR, and ST. Moreover, since there were no incidences of cardiac death in the entire study sample over the course of 2 years, we contend that the findings of the study are highly significant for both these DES designs. In this preliminary comparative trial, the device safety of BioMime SES can be affirmed to be acceptable, considering the lower three-point MACE rate and absence of late ST in the BioMime arm over the 2-year period.

2.
Cardiol Res. ; 14(4): 291-301, ago.2023. ilus
Artigo em Inglês | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1525284

RESUMO

BACKGROUND: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. METHODS: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. RESULTS: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doenças Cardiovasculares , Everolimo
3.
EuroIntervention ; 14(11): e1207-e1214, 2018 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-30222120

RESUMO

AIMS: The aim of this study was to evaluate the safety and efficacy of the BioMime sirolimus-eluting coronary stent (SES) compared to the XIENCE family of everolimus-eluting coronary stents (EES) in the treatment of patients with de novo native coronary artery lesions. METHODS AND RESULTS: The meriT-V is a prospective, multicentre, randomised, open-label, active-controlled, non-inferiority trial. A total of 256 patients with up to two de novo native coronary artery lesions were enrolled and randomly assigned (2:1) to BioMime SES or XIENCE EES. BioMime SES was non-inferior to XIENCE EES for the primary endpoint of in-stent late lumen loss (0.15±0.27 mm vs. 0.15±0.29 mm; difference: -0.006 mm; 95% confidence interval: -0.085 to 0.072; p=0.87; p for non-inferiority <0.0001) at nine-month follow-up. The major adverse cardiac events rate was numerically lower in the BioMime SES group (2.98% vs. 7.14%; p=0.13), driven by a statistically significant lower risk of any myocardial infarction (0.60% vs. 4.76%; p=0.03), when compared with the XIENCE EES group. There was no difference in target vessel myocardial infarction (p=0.62) between the groups. There was no definite or probable stent thrombosis in either group. CONCLUSIONS: In the treatment of de novo native coronary artery lesions, the biodegradable polymer ultra-thin SES (BioMime) was non-inferior to a durable polymer EES (XIENCE) at nine-month follow-up. Further studies powered for clinical endpoints are needed.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Implantes Absorvíveis , Everolimo , Humanos , Polímeros , Estudos Prospectivos , Sirolimo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA