Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Sep Sci ; 44(6): 1148-1173, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33006433

RESUMO

Bisphenol A is a synthetic compound widely used in industry, in the production of polycarbonate, epoxy resins, and thermal paper, among others. Its annual production is estimated at millions of tons per year, demonstrating its importance. Despite its wide application in various everyday products, once in the environment (due to its disposal or leaching), it has high toxicity to humans and animal life, and this problem has been well known for years. Given this problem, many researchers seek alternatives for its monitoring in matrices such as natural water, waste, food, and biological matrices. For this, new advanced materials have been developed, characterized, and applied in creative ways for the preparation of samples for the determination of bisphenol A. This article aims to present some of these important and recent applications, describing the use of molecularly imprinted polymers, metal and covalent organic frameworks, ionic liquids and magnetic ionic liquids, and deep eutectic solvents as creative solutions in sample preparation for the long-standing problem of bisphenol A determination.

2.
Talanta ; 221: 121443, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33076068

RESUMO

In widespread use in commercial products as plasticizers, phthalic acid esters (phthalates) have worried researchers and society in general, given the negative impacts on living organisms, especially human health. Since they are not chemically linked to the polymeric matrix, their migration is evident for samples that come into contact with plastics that contain them, such as water, food and saliva. In this work, a new strategy is described, named parallel-disposable pipette extraction (Pa-DPX), in a fast, efficient and robust analytical method using five simultaneous extractions for the determination of migration of 6 phthalates from common plastic materials (children's toys, school supplies, dog toys and oral contact items) to saliva simulant, using gas chromatography-mass spectrometry (GC-MS). The optimized conditions were 5 extraction cycles with 1600 µL of saliva simulant and desorption with 200 µL of ethyl acetate using 5 cycles with the same aliquot. The calibration curves resulted in determination coefficients higher than 0.9915, limits of detection at 1.5 µg L-1, and the quantification limits were 5.0 µg L-1. Excellent results were obtained for repeatability (relative standard deviation ranging from 8.7% to 20.1% for 5 µg L-1) and intermediate precision, varying the day of analyses (7.9%-16.2%). The analyte recovery ranged from 75% to 114% for two different samples, in four different levels of concentration. The Pa-DPX-GC-MS method was successfully applied to determine the migration of PAE from 21 samples. At least one PAE was detected in 81% of samples, and di-n-octyl phthalate was found in higher concentration, achieving the migration of almost 30 µg per g of sample.


Assuntos
Ácidos Ftálicos , Plásticos , Animais , Cães , Cromatografia Gasosa-Espectrometria de Massas , Ácidos Ftálicos/análise , Plastificantes/análise , Saliva/química
3.
Talanta ; 223(Pt 2): 121759, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33298275

RESUMO

In this work, a novel and high-throughput parallel-dispersive droplet extraction (Pa-DDE) based on in situ formation of the hydrophobic MILs ([Co(C4IM)4+2]2[NTf2-], [Ni(C4IM)4+2]2[NTf2-] and [Ni(BeIM)4+2]2[NTf2-]) is demonstrated, for the first time, for the determination of benzophenone, metolachlor, triclocarban, pendimethalin, 4-methylbenzylidene camphor, and 2-ethylhexyl-4-methoxycinnamate from aqueous environmental samples. This experimental setup is comprised of a 96-well plate system containing a set of magnetic pins which were used to collect the MIL droplet after in situ formation. This consolidated system enabled simultaneous extraction of up to 96 samples and MIL production in one step. Using this apparatus, sample preparation times of 0.78 min per sample was achieved. The experimental conditions were carefully optimized using uni and multivariate approaches. The optimal conditions were comprised of sample volume of 1.25 mL, 4 mg of [Co(C4IM)4+2]2[Cl-] and 40 µL of LiNTf2 for the in situ formation, and dilution in 20 µL of acetonitrile. The analytical parameters of merit were successfully determined with LODs ranging from 7.5 to 25 µg L-1 and coefficients of determination higher than 0.989. Intraday and interday precision ranged from 6.4 to 20.6% (n = 3) and 11.6-22.9% (n = 9), respectively, with analyte relative recovery ranging between 53.9 and 129.1%.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA