Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Plast Reconstr Surg Glob Open ; 12(5): e5836, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38784827

RESUMO

Charcot-Marie-Tooth (CMT) disease is the most prevalent inherited neuromuscular disorder. It commonly leads to various musculoskeletal deformities, profoundly impacting the quality of life. The present case report explores the often under-recognized body image dissatisfaction in CMT, highlighting the potential benefits of a multidisciplinary approach to enhance aesthetic satisfaction. We present a case of a 54-year-old woman with CMT, who experienced chronic facial asymmetry, significantly impairing her quality of life. Seeking cosmetic enhancement, she underwent two sessions of facial treatment using hyaluronic acid-based fillers. The first session focused on correcting right mandibular hypoplasia and other facial asymmetries, whereas the second session focused on enhancing perioral aesthetics. The treatment resulted in significant aesthetic improvements, as demonstrated by high ratings in both the Physician Global Aesthetic Improvement Scale and the Subject Global Aesthetic Improvement Scale. Besides, there was a marked reduction in lip corner asymmetry, the patient's primary concern. The role of hyaluronic acid fillers in facial aesthetic enhancement is well established, and their application in the context of CMT is a promising under-investigated field, to our knowledge. This case study highlights the importance of considering body image in CMT patients and suggests that minimally invasive aesthetic procedures can be a valuable addition to the multidisciplinary care of patients with inherited neurological disorders. Despite being a single-case study, the significant improvement in the patient's aesthetic satisfaction requires further research in this field.

2.
Skin Appendage Disord ; 7(5): 422-426, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34604337

RESUMO

Onychomatricoma is a primary benign neoplasm of the nail matrix. Currently, a limited number of cases have been reported, so it is still considered a rare neoplasia. However, it is debatable if this condition is underdiagnosed and underreported. Onychomycosis is an important differential diagnosis of onychomatricoma, and sometimes, both these conditions may even coexist in the same nail. As the tumor grows, tissue microenvironment is more vulnerable to dermatophytes. Probably, the altered keratin appears to be susceptible to fungal invasion. Careful clinical assessment and dermoscopic evaluation help nailing the diagnosis. Usually, total nail avulsion is the preferred therapeutic approach when they coexist. Herein, we present a case of a middle-aged woman with onychomycosis and onychomatricoma affecting a single fingernail. The proposed therapy was oral terbinafine for 6 months followed by a conservative surgery. There were dramatic changes in dermoscopic features after fungal treatment, which, to our knowledge, have not been previously reported.

3.
Respir Care ; 62(2): 215-221, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27729399

RESUMO

BACKGROUND: The use of esophageal catheters with microtransducer promises advantages over traditional catheters with air-filled balloons. However, performance comparisons between these 2 types of catheters are scarce and incomplete. METHODS: A catheter with a 9.5-cm air-filled balloon at the distal tip and a catheter with a microtransducer mounted within a flexible silicone rubber were tested in vitro and in vivo. In vitro, the response times of both catheters were compared, and the drift of the baseline pressure of the microtransducer catheter was evaluated over a 6-h period. In vivo, 11 healthy volunteers had both catheters inserted, and the drift of the baseline esophageal pressure was measured over a 3-h period. Also, the correlation and agreement of the baseline and changes in the esophageal pressure of both catheters were evaluated. RESULTS: In vitro, the microtransducer catheter had a response time significantly higher (262 × 114 Hz, P < .01) and a good pressure stability, with a mean baseline pressure drift of 1.4 cm H2O. In vivo, both catheters presented a small and similar baseline esophageal pressure drift (P = 0.08). For measurements of baseline and changes in esophageal pressure, the correlation and agreement between the catheters were poor, with a large bias between them. CONCLUSIONS: The catheter with the microtransducer had a small baseline pressure drift, similar to the air-filled balloon catheter. The low agreement between the catheters does not allow the microtransducer catheter to be used as a surrogate for the traditional air-filled balloon catheter.


Assuntos
Catéteres , Esôfago/fisiologia , Manometria/instrumentação , Monitorização Ambulatorial/instrumentação , Transdutores de Pressão , Adulto , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Pressão , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA