RESUMO
Introduction: To compare the functional results, satisfaction rates, and revisions of total knee arthroplasties performed by the same surgical team using either Brazilian or imported implants, with a minimum follow-up of 5 years after surgery. Materials and Methods: A retrospective cohort study analyzing the medical records and interviews of patients who underwent total knee arthroplasty with Brazilian or imported implants with a minimum of 5 years after surgery. Results: One hundred and fifty patients were evaluated (164 knees). In the functional questionnaire, 71% of patients had favorable answers in the group of patients who underwent surgery using the Brazilian prosthesis and 74.8% in the group with imported implants (p=0.634). There was no statistical difference in satisfaction between the groups, with 78.4% of patients satisfied or very satisfied in the Brazilian implant group and 90.7% in the imported implant group (p=0.053). Loosening of the implants was reported in 5.3% versus 4.7% (p>0.999). Conclusion: The total knee arthroplasties performed by the same surgical team with a minimum follow-up period of 5 years showed similar levels of satisfaction, function, and complications with both the Brazilian and imported implants. Level of Evidence III, cohort study.
Introdução: Comparar resultados funcionais, índices de satisfação e revisões de artroplastias totais de joelho realizadas pela mesma equipe cirúrgica usando implantes brasileiros ou importados, com acompanhamento mínimo de cinco anos após a cirurgia. Material e Método: Estudo de coorte retrospectivo com análise de prontuários e entrevistas de pacientes submetidos à artroplastia total do joelho com implantes brasileiros e importados com no mínimo cinco anos de pós-operatório. Resultados: Foram avaliados 150 pacientes (164 joelhos). No questionário funcional, encontramos 71% dos pacientes com respostas favoráveis no grupo de pacientes submetidos à cirurgia com uso de próteses brasileiras e 74,8% no grupo com implantes importados (p = 0,634). Em relação à satisfação, não houve diferença estatística entre os grupos com 78,4% dos pacientes satisfeitos ou muito satisfeitos no grupo com implante brasileiro e 90,7% no grupo com implante importado (p = 0,053). A ocorrência de soltura dos implantes foi relatada em 5,3% versus 4,7% (p > 0,999). Conclusões: As artroplastias totais de joelho realizadas pela mesma equipe cirúrgica com acompanhamento mínimo de cinco anos apresentaram níveis semelhantes de satisfação, função e complicações com os implantes brasileiros e importados. Nível de evidência III, estudo de coorte.
RESUMO
ABSTRACT Introduction To compare the functional results, satisfaction rates, and revisions of total knee arthroplasties performed by the same surgical team using either Brazilian or imported implants, with a minimum follow-up of 5 years after surgery. Materials and Methods A retrospective cohort study analyzing the medical records and interviews of patients who underwent total knee arthroplasty with Brazilian or imported implants with a minimum of 5 years after surgery. Results One hundred and fifty patients were evaluated (164 knees). In the functional questionnaire, 71% of patients had favorable answers in the group of patients who underwent surgery using the Brazilian prosthesis and 74.8% in the group with imported implants (p=0.634). There was no statistical difference in satisfaction between the groups, with 78.4% of patients satisfied or very satisfied in the Brazilian implant group and 90.7% in the imported implant group (p=0.053). Loosening of the implants was reported in 5.3% versus 4.7% (p>0.999). Conclusion The total knee arthroplasties performed by the same surgical team with a minimum follow-up period of 5 years showed similar levels of satisfaction, function, and complications with both the Brazilian and imported implants. Level of Evidence III, cohort study.
RESUMO Introdução Comparar resultados funcionais, índices de satisfação e revisões de artroplastias totais de joelho realizadas pela mesma equipe cirúrgica usando implantes brasileiros ou importados, com acompanhamento mínimo de cinco anos após a cirurgia. Material e Método Estudo de coorte retrospectivo com análise de prontuários e entrevistas de pacientes submetidos à artroplastia total do joelho com implantes brasileiros e importados com no mínimo cinco anos de pós-operatório. Resultados Foram avaliados 150 pacientes (164 joelhos). No questionário funcional, encontramos 71% dos pacientes com respostas favoráveis no grupo de pacientes submetidos à cirurgia com uso de próteses brasileiras e 74,8% no grupo com implantes importados (p = 0,634). Em relação à satisfação, não houve diferença estatística entre os grupos com 78,4% dos pacientes satisfeitos ou muito satisfeitos no grupo com implante brasileiro e 90,7% no grupo com implante importado (p = 0,053). A ocorrência de soltura dos implantes foi relatada em 5,3% versus 4,7% (p > 0,999). Conclusões As artroplastias totais de joelho realizadas pela mesma equipe cirúrgica com acompanhamento mínimo de cinco anos apresentaram níveis semelhantes de satisfação, função e complicações com os implantes brasileiros e importados. Nível de evidência III, estudo de coorte.