Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz Oral Res ; 37: e059, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37341232

RESUMO

The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.


Assuntos
Cavidade Pulpar , Tratamento do Canal Radicular , Humanos , Cavidade Pulpar/diagnóstico por imagem , Microtomografia por Raio-X , Dente Molar/diagnóstico por imagem , Período Pós-Operatório
2.
Braz. oral res. (Online) ; 37: e059, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS, BBO - Odontologia | ID: biblio-1439753

RESUMO

Abstract The aim of this study was to compare the quantification of hard-tissue debris by using micro-computed tomography (micro-CT) and nano-focus computed tomography (nano-CT) after root canal instrumentation. Ten mandibular molars containing an isthmus in the mesial root were scanned in a SkyScan 1172 micro-CT device with a voxel size of 12.8 µm and in a NanoTom nano-CT device with 5.5 µm. The mesial root canals were irrigated with 5 mL of saline solution at the orifice level, instrumented with Reciproc R25 files and a second scanning was performed by micro-CT and nano-CT devices for post-instrumentation images. DataViewer software was used for registering the pre- and post-operative micro-CT and nano-CT images. The root canal and the debris were segmented for quantitative analysis of the volume of the canal and volume of debris using CTAn software. Statistical analysis was performed using the T test for comparison between volume of the canal after instrumentation and volume of debris in both image modalities. The level of significance was set at p < 0.05. Nano-CT images showed higher values of debris when compared with micro-CT (p < 0.05) after root canal instrumentation. No difference was observed between the volume of the root canal after instrumentation in the two imaging methods used (p > 0.05). Nano-CT technology can be recommended as a more precise method for quantitative analysis of hard-tissue debris. Moreover, in Endodontic research it is a promising method, as it is capable of providing higher spatial and contrast resolution, faster scanning and higher image quality.

3.
Aust Endod J ; 47(3): 631-638, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34097337

RESUMO

The aim of this study was to compare the efficacy of UAI with ESI, sonic activation with Eddy® and syringe irrigation in removing debris, and dentin removal during canal irrigation. Twenty-four mandibular molars containing isthmus type V and with a mean curvature of 32.5° were instrumented and divided into three groups for final irrigation: UAI with ESI, sonic activation with Eddy and syringe irrigation. The samples were scanned in a SkyScan 1172 micro-CT device for pre-, post-instrumentation and post-irrigation images and analysis of dentin removal. Statistical analysis was performed using Wilcoxon, Kruskal-Wallis and Dunn tests. UAI and sonic activation significantly improved debris removal (P < 0.05). No significant difference was observed regarding dentin removal between the groups (P > 0.05), although higher values were found for UAI. Sonic activation with Eddy® showed to be an effective and safe device since it was able to remove debris without causing damage to the canal walls.


Assuntos
Projetos de Pesquisa , Seringas , Dentina , Microtomografia por Raio-X
4.
Dentomaxillofac Radiol ; 50(5): 20200503, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-33400563

RESUMO

OBJECTIVES: To evaluate the influence of artefacts in cone beam CT (CBCT) images of filled root canals in isthmus-containing molars. METHODS: 10 teeth presenting canals with an isthmus were instrumented and filled with a thermoplasticised obturation technique. The teeth were scanned using a micro-CT device and two CBCT devices: 3D Accuitomo 170 (ACC) and NewTom VGi evo (NT), with different acquisition protocols: larger and smaller voxel size. Three examiners assessed the CBCT images for: (1) detection of filling voids; (2) assessment of under- or overestimation of the filling material and (3) resemblance of CBCT images to the reference standard. Analyses of Task 1 yielded accuracy, sensitivity and specificity for detection of filling voids. For tasks 2 and 3, statistical analysis was performed using Wilcoxon test. The level of significance was set at p < .05. RESULTS: For Task 1, ACC showed higher sensitivity, whereas NT presented higher specificity. No significant difference was found between the protocols in ACC, however, for NT, differences between protocols were significant for all diagnostic values. In Task 2, visualisation of the filling was overestimated for NT, while for ACC, underestimation was observed. For Task 3, images with smaller voxel size were more similar to the reference image, for both CBCT devices. CONCLUSIONS: Different artefacts compromise the detection of filling voids on CBCT images of canals in mandibular molars with isthmus. ACC and NT present rather similar diagnostic accuracy, even though artefact expression remains device-specific.


Assuntos
Artefatos , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico , Cavidade Pulpar/diagnóstico por imagem , Humanos , Dente Molar/diagnóstico por imagem , Obturação do Canal Radicular
5.
Eur Endod J ; 5(2): 105-111, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32766519

RESUMO

Objective: This study aimed to investigate the root canal system morphology of maxillary first molar mesiobuccal (MB) roots in a Brazilian sub-population using micro-computed tomography. Methods: Ninety-six MB roots were scanned with a micro-CT (Skyscan 1173, Bruker). Three-dimensional images were analyzed regarding the number of pulp chamber orifices, the number and classification of the canals, the presence of accessory canals in different thirds of the root as well as the number and type of apical foramina. Results: A single entrance orifice was found in 53.0% of the samples, two in 43.9% and only 3.1% had three orifices. The second mesiobuccal root canal (MB2) was present at some portion of the root in 87.5% of the specimens. A single apical foramen was present in 16.7%, two in 22.9%, and three or more foramina in 60.4% of the roots. Only 55.3% and 76.1% of the root canals could be arranged by Weine's and Vertucci's classifications, respectively. Conclusion: The number of orifices at the pulp chamber level could not work as a predictor of the MB2 presence. The most prevalent canal configuration was Weine type IV / Vertucci type V. The anatomical complexity of the MB root could not be entirely classified by the current most accepted classifications.


Assuntos
Cavidade Pulpar/diagnóstico por imagem , Imageamento Tridimensional/métodos , Maxila/diagnóstico por imagem , Dente Molar/diagnóstico por imagem , Raiz Dentária/diagnóstico por imagem , Microtomografia por Raio-X/métodos , Brasil , Humanos , Ápice Dentário/diagnóstico por imagem
6.
Artigo em Inglês | MEDLINE | ID: mdl-26047162

RESUMO

The objective of this work was to propose an automated and direct process to grade tooth wear intra-orally. Eight extracted teeth were etched with acid for different times to produce wear and scanned with an intra-oral optical scanner. Computer vision algorithms were used for alignment and comparison among models. Wear volume was estimated and visual scoring was achieved to determine reliability. Results demonstrated that it is possible to directly detect submillimeter differences in teeth surfaces with an automated method with results similar to those obtained by direct visual inspection. The investigated method proved to be reliable for comparison of measurements over time.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Desgaste dos Dentes , Algoritmos , Calibragem , Humanos , Modelos Teóricos , Reprodutibilidade dos Testes , Dente
7.
Imaging Sci Dent ; 45(2): 95-101, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26125004

RESUMO

PURPOSE: This study used cone-beam computed tomography (CBCT) to characterize mandibular molar root and canal morphology and its variability in Belgian and Chilean population samples. MATERIALS AND METHODS: We analyzed the CBCT images of 515 mandibular molars (257 from Belgium and 258 from Chile). Molars meeting the inclusion criteria were analyzed to determine (1) the number of roots; (2) the root canal configuration; (3) the presence of a curved canal in the cross-sectional image of the distal root in the mandibular first molar and (4) the presence of a C-shaped canal in the second mandibular molar. A descriptive analysis was performed. The association between national origin and the presence of a curved or C-shaped canal was evaluated using the chi-squared test. RESULTS: The most common configurations in the mesial root of both molars were type V and type III. In the distal root, type I canal configuration was the most common. Curvature in the cross-sectional image was found in 25% of the distal canals of the mandibular first molars in the Belgian population, compared to 11% in the Chilean population. The prevalence of C-shaped canals was 10% or less in both populations. CONCLUSION: In cases of unclear or complex root and canal morphology in the mandibular molars, CBCT imaging might assist endodontic specialists in making an accurate diagnosis and in treatment planning.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA