Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Prosthodont ; 2023 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-37675950

RESUMO

PURPOSE: The purpose of this 3D finite element analysis was to evaluate the biomechanical effects of different materials used to fabricate occlusal devices to achieve stress distribution in simulated abutment screws, dental implants, and peri-implant bone tissue in individuals who clench their teeth. MATERIALS AND METHODS: Eight 3D models simulated a posterior maxillary bone block with three external hexagon implants (Ø4.0 × 7.0 mm) supporting a 3-unit screw-retained metal-ceramic prosthesis with different crown connection (splinting), and the use of an occlusal device (OD). The OD was modeled to be 2-mm thick. ANSYS 19.2 software was used to generate the finite-element models in the pre-and post-processing phases. Simulated abutment screws and dental implants were evaluated by von Mises stress maps, and simulated bone was evaluated by maximum principal stress and microstrain maps by using a finite element software program. RESULTS: The highest stress values in the dental implants and screws were observed in single crowns without OD (M1). Furthermore, the highest stress values and bone tissue strain were found in single crowns without OD (M1). The simulated material for the OD did not cause many discrepancies in terms of the stress magnitude in the simulated dental implant and abutment screw for both single and splinted crowns; however, more rigid materials exhibited lower stress values. CONCLUSION: The use of OD was effective in reducing stress in the simulated implants and abutment screws and stress and strain in the simulated bone tissue. The material used to simulate the OD influenced the biomechanical behavior of implant-supported fixed prostheses, whereas splints with rigid materials such as PEEK and PMMA exhibited better biomechanical behavior.

2.
J Prosthodont ; 31(8): 697-704, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34859540

RESUMO

PURPOSE: To assess the effects of tilted external hexagon implants and splinted restorations in terms of stress distribution on the bone tissue, implants, and prosthetic screws, using three-dimensional finite element analysis. MATERIALS AND METHODS: Six models were used to simulate a posterior maxilla bone block (type IV) from the first premolar to the first molar. Each model included three 4.1-mm-diameter external hexagon implants with varying inclinations (0°, 17°, and 30°) and crown designs (splinted and nonsplinted restorations). The forces applied were as follows: 400 N axially (50 N for each slope of the cusp) and 200 N obliquely (45° only on the buccal slope of the cusp). Stress distribution on the implants and prosthetic screw was evaluated using Von Mises stress, while the maximum principal stress was used to evaluate the stress distribution in the bone tissue. RESULTS: The oblique load increased the stress on all the structures in all the models. Increased inclination of the implants resulted in higher stress concentration in the bone tissue, implants, and prosthetic screws. However, splinted restorations contributed to reduction of the stress for the oblique loading, mainly in the bone tissue and prosthetic screw of the first molar, as the stress was shared between the first and second premolar restorations. CONCLUSIONS: Tilted implants increased proportionally the stress on bone tissue and prosthetic screws of models. Additionally, splinting restorations reduced the stress concentration area in the simulated bone tissue, implants, and prosthetic screws in the first molar, as the stress was shared with the adjacent implants.


Assuntos
Implantes Dentários , Maxila , Análise de Elementos Finitos , Maxila/cirurgia , Prótese Dentária Fixada por Implante/métodos , Análise do Estresse Dentário , Estresse Mecânico , Fenômenos Biomecânicos
3.
J Prosthet Dent ; 126(2): 223.e1-223.e8, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34099274

RESUMO

STATEMENT OF PROBLEM: Whether providing an occlusal device for a patient with bruxism and an implant-supported fixed dental prosthesis leads to improved biomechanics is unclear. PURPOSE: The purpose of this 3D finite element analysis (FEA) study was to evaluate the biomechanical behavior of 3-unit implant-supported prostheses under parafunctional forces with and without an occlusal device. MATERIALS AND METHODS: Eight 3D models consisting of a posterior (type IV) maxillary bone block with 3 external hexagon implants (Ø4.0×7.0 mm) and 3-unit implant-supported prostheses with different crown connections (splinted or unsplinted) and an occlusal device under functional and parafunctional loading were simulated. The abutment screws were evaluated by von Mises stress maps, and the bone tissue by maximum principal stress and microstrain maps by using a finite element software program. RESULTS: An occlusal device improved the biomechanical behavior of the prostheses by reducing stress in the abutment screws and stress and strain in the bone tissue. However, the use of an occlusal device was not sufficiently effective to negate the biomechanical benefit of splinting. CONCLUSIONS: The use of splinted crowns in the posterior maxillary region with an occlusal device was the most effective method of reducing stress in the abutment screws and stress and strain in the bone tissue when parafunction was modeled.


Assuntos
Implantes Dentários , Prótese Dentária Fixada por Implante , Fenômenos Biomecânicos , Coroas , Planejamento de Prótese Dentária , Análise do Estresse Dentário , Análise de Elementos Finitos , Humanos , Estresse Mecânico
5.
Mater Sci Eng C Mater Biol Appl ; 102: 66-74, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31147038

RESUMO

The purpose of this in vitro study was to measure the vertical, positive-horizontal, and negative-horizontal misfit (VM, PHM, and NHM, respectively) of the zirconia three-element prosthetic framework, fabricated using different methods, and compare them with conventional fabrication methods (lost-wax casting). Furthermore, this study aimed to evaluate the influence of the misfit values on the biomechanical behavior of the 3-unit fixed prosthetic frameworks using three-dimensional finite element analysis (3D-FEA). Forty frameworks (n = 10) were fabricated as follow: G1, Cerec Bluecam; G2, iTero; G3, 3Series; and G4, conventional method. The samples were randomized to measure marginal misfit using a high-precision three-dimensional (3D)-optical microscope. The results were submitted to analysis of variance (ANOVA), with the significance level set at 5%. The mean VM values of each group were used in creating the models by 3D-FEA with the misfit found in optical microscopy. The programs used were the InVesalius, Rhinoceros, SolidWorks, FEMAP and NEiNastran. The von Mises map was plotted for each model. The G4 showed the lowest mean VM value (16.73 µm), followed by G3 (20.71 µm), G2 (21.01 µm), and G1 (41.77 µm) (p < 0.001). G2 was more accurate than G1 (p < 0.05) and similar to G3 (p = 0.319). For PHM, G4 was the most accurate and did not present overextended values. With regard to NHM, the computer-aided design and computer-aided manufacturing (CAD-CAM) systems were more accurate (-61.91 µm) than G4 (-95.36 µm) (p = 0.014). In biomechanical analysis, stress concentration caused by oblique loading is greater than caused by axial loading. In axial loading, G4 was the most favorable while G1 was the least favorable, biomechanically, in oblique loading, similar stress patterns were observed in all the models. The prosthetic screw was the most overloaded structure, but the material did not influence the stress distribution. The misfit prostheses showed a greater degree of stress than the controls (without misfit). The manufacturing method influenced the marginal misfit of the frameworks, with the conventional method being the most accurate and the Cerec Bluecam System (closed system) the least accurate. Biomechanically, fitting prostheses were more favorable than misfit prostheses.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária/métodos , Estresse Mecânico , Simulação por Computador , Análise de Elementos Finitos
6.
Obes Surg ; 29(5): 1675-1680, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30835020

RESUMO

Bariatric surgery is the most effective treatment for morbid obesity, but it can cause numerous adverse effects. This systematic review and meta-analysis aimed to evaluate whether bariatric surgery changes patient salivary flow. We searched for articles in the Web of Science, Pubmed/MEDLINE, and Scopus databases using the search terms "oral health AND bariatric surgery OR gastrectomy OR obesity surgery." We recovered 845 articles. After the removal of duplicates and exclusions, eight studies remained. Of them, five showed no significant difference in salivary flow values, two showed an increase in flow rate, and one showed a reduction in flow rate (p < 0.05). The results of the included studies showed no significant alteration in salivary flow rate for up to 24 months after bariatric surgery.


Assuntos
Cirurgia Bariátrica , Salivação , Humanos
7.
Int J Dent ; 2018: 7868531, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30510576

RESUMO

A systematic review was performed to evaluate whether whitening toothpastes promote tooth whitening when compared to the use of conventional (nonbleaching) dentifrices. This review was registered at PROSPERO (CRD42017065132) and is based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses. Electronic systematic searches of PubMed/MEDLINE, Scopus, and the Cochrane Library were conducted for published articles. Only randomized clinical trials in adults that compared the use of so-called whitening dentifrices to the use of nonwhitening dentifrices were selected. The outcome was tooth color change. Twenty-two articles from 703 data sources met the eligibility criteria. After title and abstract screening, 16 studies remained, after which a further five studies were excluded. In total, nine studies were qualitatively analyzed. Significant differences in tooth color change were found between the groups using whitening dentifrices and those using nonwhitening dentifrices. Within the limitations of this study, the evidence from this systematic review suggests that bleaching dentifrices have potential in tooth whitening. However, although many whitening dentifrices have been introduced into the dental market for bleaching treatments, it is important to analyze tooth surface and color changes when performing home bleaching.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA