Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 36(6): 1857-1863, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33579631

RESUMO

BACKGROUND: Optimizing surgical trays to improve operating room efficiency and reduce costs in instrument processing is an under-appreciated strategy for cost containment. This study aimed to assess the economic impact of instrument tray optimization in total joint arthroplasty. METHODS: Thirty-five randomly selected elective primary total knee arthroplasty and total hip arthroplasty performed by 4 fellowship-trained surgeons were analyzed. Type and number of instruments used as well as timing of different steps in the sterilization process were recorded by an independent observer. Using Lean methodology, surgeons identified redundant or underutilized instruments and agreed upon the fewest number needed for each tray. Instrument utilization rates and processing time were analyzed before and after tray modifications. Annual cost savings were calculated based on a processing factor of $0.59-$11.52 per instrument. RESULTS: Only 45.5% of instruments opened for total knee arthroplasty were utilized. After optimization, 28 of 87 (32.2%) instruments were removed and the remainder could be stored in one tray. Mean set-up time decreased from 20.7 to 14.2 minutes, while 40-75 minutes were saved during the sterilization process. For total hip arthroplasty, only 36.0% of instruments were utilized. Using Lean methods, 46 of 112 (41.1%) instruments were removed and tray count was reduced to 2 trays. Mean set-up time decreased from 27.9 to 18.6 minutes, while 45-150 minutes were saved during processing. Average annual savings amounted to $281,298.05. CONCLUSION: Lean methodology can be used to eliminate redundant or underutilized instruments in total joint arthroplasty, improving surgical efficiency and generating substantial cost savings.


Assuntos
Salas Cirúrgicas , Instrumentos Cirúrgicos , Artroplastia , Redução de Custos , Humanos , Esterilização
2.
J Arthroplasty ; 35(9): 2318-2322, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32423758

RESUMO

BACKGROUND: The Centers for Medicare and Medicaid Services has recently designated the codes for total hip and knee arthroplasty as misvalued and has asked the Relative Value Scale Update Committee (RUC) to review the work required to perform these procedures. Although other studies have reported time spent on perioperative and postoperative care, time spent on coordinating and performing preoperative care is not included in current RUC methodology and has yet to be addressed in literature. METHODS: We prospectively tracked a consecutive series of 438 primary total hip arthroplasty and total knee arthroplasty patients by one of the 5 surgeons over a 3-month period. Each clinical staff member tracked the amount of time to perform each preoperative care task from the last clinic visit until day of surgery. Data were analyzed separately between providers and ancillary medical staff. RESULTS: Although the current RUC review includes 40 minutes of preservice time on the day of surgery, surgeons spent an average of an additional 43.2 minutes while physician assistants and nurse practitioners spent an additional 97.9 minutes per patient on preoperative care prior to that time. Ancillary medical staff spent a mean of 110.2 minutes per patient. The most common tasks include preoperative phone calls, templating and surgical planning, and preoperative patient education classes. CONCLUSION: Surgeons and advanced practice providers spend nearly 2 hours per arthroplasty patient on preoperative care not accounted for in current RUC methodology. As readmissions, hospital stay, and complication rates continue to decline, Centers for Medicare and Medicaid Services should consider the substantial work required during the preoperative phase to allow for these improved outcomes.


Assuntos
Artroplastia de Quadril , Artroplastia do Joelho , Idoso , Humanos , Tempo de Internação , Medicare , Escalas de Valor Relativo , Estados Unidos/epidemiologia
3.
J Arthroplasty ; 35(5): 1228-1232, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32115328

RESUMO

BACKGROUND: Controlling postoperative pain and reducing opioid requirements after total knee arthroplasty remain a challenge, particularly in an era stressing rapid recovery protocols and early discharge. A single-shot adductor canal blockade (ACB) has been shown to be effective in decreasing postoperative pain. The purpose of the present study is to compare the efficacy of an anesthesiologist administered ACB and a surgeon administered intraoperative ACB. METHODS: Patients undergoing primary total knee arthroplasty were prospectively randomized to receive either an anesthesiologist administered (group 1) or surgeon administered (group 2) ACB using 15 mL of ropivacaine 0.5%. Primary outcomes were pain visual analog scale, range of motion, and opioid consumption. RESULTS: Thirty-four patients were randomized to group 1 and 29 to group 2. Opioid equivalents consumed were equal on postoperative day (POD) 0, 1, and 2. Patients in group 1 had statistically less pain on POD 0, but this did not reach clinical significance and there was no difference in pain on POD 1 or 2. Patients in group 1 had significantly increased active flexion POD 1, but there was no difference in active flexion on POD 0 or 6 weeks postop. There was no difference in patient satisfaction with pain control or short-term functional outcomes. CONCLUSION: Surgeon administered ACB is not inferior to anesthesiologist administered ACB with respect to pain, opioid consumption, range of motion, patient satisfaction, or short-term functional outcomes. Surgeon administered ACB is an effective alternative to anesthesiologist administered ACB.


Assuntos
Bloqueio Nervoso , Cirurgiões , Anestesiologistas , Anestésicos Locais , Humanos , Dor Pós-Operatória/prevenção & controle , Estudos Prospectivos , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
J Arthroplasty ; 35(4): 955-959, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31983564

RESUMO

BACKGROUND: Total joint arthroplasty (TJA) can be successfully carried out under general (GA) or spinal anesthesia (SA). The existing literature does not adequately illustrate which technique is optimal. The purpose of this study is to prospectively compare the effects of anesthesia technique on TJA outcomes. METHODS: This 2-year, prospective, observational study was conducted at a single institution where patients receiving primary TJA were consecutively enrolled. Patients were contacted postoperatively to assess for any 90-day complications. The primary outcome of the study was the overall complication rate. RESULTS: A total of 2242 patients underwent total hip arthroplasty (n = 656; 29.26%) or total knee arthroplasty (n = 1586; 70.74%) between 2015 and 2017. Of these procedures, 1325 (59.10%) were carried out under SA and 917 (40.90%) were carried out under GA. Patients in the GA cohort had higher mean Charlson Comorbidity Index scores (0.05 SA vs 0.09 GA; P < .05) and higher average body mass index (29.35 SA vs 30.24 GA; P < .05). On multivariate analysis, patients in the SA cohort had a significantly lower overall complication rate relative to their GA counterparts (7.02% vs 10.14%; odds ratio, 0.66; 95% confidence interval, 0.49-0.90; P < .05). In addition, length of stay in the GA cohort was significantly longer (2.43 [SD, 1.62] vs 2.18 [SD, 0.88] days; P < .01) and a larger percentage of GA patients were discharged to a nursing facility (32.28% vs 25.06%; odds ratio, 0.55; 95% confidence interval, 0.44-0.70; P < .05). CONCLUSION: Our study demonstrates that SA for TJA is associated with a decrease in overall complications and healthcare resource utilization.


Assuntos
Raquianestesia , Artroplastia de Quadril , Artroplastia do Joelho , Anestesia Geral , Raquianestesia/efeitos adversos , Artroplastia de Quadril/efeitos adversos , Artroplastia do Joelho/efeitos adversos , Humanos , Complicações Pós-Operatórias , Estudos Prospectivos , Estudos Retrospectivos
5.
J Arthroplasty ; 35(3): 756-761, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31761673

RESUMO

BACKGROUND: Probability-based computer algorithms that reduce patient burden are currently in high demand. These computer adaptive testing (CAT) methods improve workflow and reduce patient frustration, while achieving high measurement precision. In this study, we evaluated the accuracy and validity of the CAT Hip Disability and Osteoarthritis Outcome Score (HOOS) and the Hip Disability and Osteoarthritis Outcome Score Joint Replacement (HOOS-JR) by comparing them to the full version of these scoring systems in a subset of patients who had undergone total hip arthroplasties. METHODS: A previously developed CAT HOOS and HOOS-JR was applied to 354 and 1547 HOOS and HOOS-JR patient responses, respectively. Mean, standard deviations, Pearson's correlation coefficients, interclass correlation coefficients, frequency distribution plots, and Bland-Altman plots were used to compare the precision, validity, and accuracy between CAT scores and full-form scores. RESULTS: By modifying the questions to past responses, the CAT HOOS demonstrated a mean reduction of 30% of questions (28 vs 40 questions). There were no significant differences between the full HOOS and CAT HOOS with respect to pain (P = .73), symptoms (P = .94), quality of life (P = .99), activities of daily living (P = .82), and sports (P = .99). There were strong linear relationships between the CAT versions and the standard questionnaires (r > 0.99). The Bland-Altman plot showed that differences between CAT HOOS and full HOOS were independent of the overall scores. CONCLUSION: The CAT HOOS and HOOS-JR have high correlation and require fewer questions to finish compared to the standard full-form questionnaires. This may represent a reliable and practical alternative that may be less burdensome to patients and may help improve compliance for reporting outcome metrics.


Assuntos
Artroplastia de Quadril , Osteoartrite do Quadril , Atividades Cotidianas , Computadores , Humanos , Osteoartrite do Quadril/cirurgia , Medidas de Resultados Relatados pelo Paciente , Pacientes , Qualidade de Vida , Reprodutibilidade dos Testes , Inquéritos e Questionários
6.
J Arthroplasty ; 34(8): 1640-1645, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31084971

RESUMO

BACKGROUND: Multiple studies have demonstrated that ketamine, a glutamate receptor blocker, may decrease postoperative pain in abdominal and orthopedic surgeries. However, its role with spinal anesthesia and total knee arthroplasty (TKA) remains unknown. The purpose of this study is to determine the efficacy of subanesthetic dosing of ketamine during TKA on postoperative pain and narcotic consumption. METHODS: In this prospective, randomized, double-blinded clinical trial, we enrolled 91 patients undergoing primary TKA with spinal anesthesia in a single institution from 2017 to 2018. Patients were randomized to receive intraoperative ketamine infusion at a rate of 6 mcg/kg/min for 75 minutes or a saline placebo. All patients received spinal anesthesia and otherwise identical surgical approaches, pain management, and rehabilitation protocols. Patient-reported visual analog pain scores were calculated preoperatively, postoperative days (POD) 0-7, and 2 weeks. Narcotic consumption was evaluated on POD 0 and 1. RESULTS: There was no difference in average pain between ketamine and placebo at all time points except for at PODs 1 (45 vs 56, P = .041) and 4 (39 vs 49, P = .040). For least pain experienced, patients administered with ketamine experienced a reduction in pain only at POD 4 (22 vs 35, P = .011). There was no difference in maximum pain cohorts at all time points of the study or in-hospital morphine equivalents between the 2 cohorts. CONCLUSION: As part of multimodal pain management protocol, intraoperative ketamine does not result in a clinically significant improvement in pain and narcotic consumption following TKA.


Assuntos
Analgesia Controlada pelo Paciente/métodos , Analgésicos Opioides/administração & dosagem , Artroplastia do Joelho , Ketamina/uso terapêutico , Entorpecentes/uso terapêutico , Idoso , Raquianestesia/métodos , Método Duplo-Cego , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Morfina/uso terapêutico , Manejo da Dor/métodos , Medição da Dor , Dor Pós-Operatória/tratamento farmacológico , Período Pós-Operatório , Estudos Prospectivos
7.
Surg Technol Int ; 27: 225-32, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26680402

RESUMO

PURPOSE: Accurate alignment and balanced flexion and extension gaps are critical elements in achieving a successful outcome following total knee arthroplasty (TKA). The ability to make accurate and precise bone cuts is essential in the creation of balanced gaps. We sought to determine if one type of modern-day standard surgical instrument using an intramedullary rod and posterior referencing produces accurate and precise distal and posterior femoral bone resections. MATERIALS AND METHODS: Seventy-five consecutive patients undergoing TKA were divided into three groups, with 25 patients in each group receiving one of three implant designs: 25 Stryker Triathlon® CR (Stryker, Mahwah, NJ), 25 Zimmer NexGen® Flex CR (Zimmer, Warsaw, IN), and 25 StelKast Proven Gen-FlexTM CR (StelKast, Pittsburgh, PA). Flexion-extension gap matching was determined using only the medial flexion and extension gaps. Accuracy was determined by comparing actual resection thickness to desired resection thickness. "Optimal" accuracy was considered to be within 1.0mm of desired, and "near-optimal" accuracy was considered to be within 2.0mm of the desired resection thickness. Precision was determined by the variability of resection thicknesses within each system. RESULTS: Data demonstrated a lack of accuracy and precision across all three tested systems, with each system resulting in certain unique tendencies. Only one out of 75 cases resulted in optimal resection accuracy with all three cuts (Zimmer). When lowering the threshold to include both optimal and near-optimal (within 2 mm of error) with all three cuts, only one third of Stryker and Zimmer cases and two thirds of StelKast cases achieved this threshold, representing 44% of cases (33/75). CONCLUSIONS: Improvements in instrumentation to increase accuracy and precision may be warranted. Errors in fixation may be due to the instrumentation itself, and altering instrumentation to include less modularity, provide more stable fixation, and more reliably seal the implant on the femur may be of benefit.


Assuntos
Artroplastia do Joelho , Fêmur/cirurgia , Artroplastia do Joelho/instrumentação , Artroplastia do Joelho/métodos , Artroplastia do Joelho/normas , Artroplastia do Joelho/estatística & dados numéricos , Humanos , Articulação do Joelho/cirurgia , Prótese do Joelho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA