Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Rev. bras. oftalmol ; 81: e0103, 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1407672

RESUMO

ABSTRACT Optical coherence tomography is often used for detection of glaucoma as well as to monitor progression. This paper reviews the most common types of artifacts on the optical coherence tomography report that may be confused with glaucomatous damage. We mainly focus on anatomy-related artifacts in which the retinal layer segmentation and thickness measurements are correct. In such cases, the probability maps (also known as deviation maps) show abnormal (red and yellow) regions, which may mislead the clinician to assume disease is present. This is due to the anatomic variability of the individual, and the normative database must be taken into account.


RESUMO A tomografia de coerência óptica é frequentemente usada para detectar glaucoma, bem como para monitorar a progressão. Este artigo analisa os tipos mais comuns de artefatos no relatório de tomografia de coerência óptica que podem ser confundidos com danos glaucomatosos. Nós nos concentramos principalmente nos artefatos relacionados à anatomia em que a segmentação da camada da retina e as medidas de espessura estão corretas. Nesses casos, os mapas de probabilidade (também conhecidos como mapas de desvio) mostram regiões anormais (vermelho e amarelo), o que pode induzir o clínico em erro ao supor que a doença está presente. Isto se deve à variabilidade anatômica do indivíduo, e o banco de dados normativo deve ser levado em conta.


Assuntos
Humanos , Glaucoma/diagnóstico por imagem , Artefatos , Tomografia de Coerência Óptica/métodos , Postura , Retina/diagnóstico por imagem , Anormalidade Torcional , Movimentos da Cabeça , Erros de Diagnóstico , Movimentos Oculares , Fóvea Central , Fibras Nervosas/patologia
2.
Ophthalmology ; 123(10): 2058-65, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-27554036

RESUMO

PURPOSE: To evaluate the relationship between intraocular pressure (IOP) and rates of retinal nerve fiber layer (RNFL) thickness change over time measured by spectral-domain (SD) optical coherence tomography (OCT). DESIGN: Observational cohort study. PARTICIPANTS: The study involved 547 eyes of 339 patients followed up for an average of 3.9±0.9 years. Three hundred eight (56.3%) had a diagnosis of glaucoma and 239 (43.7%) were considered glaucoma suspects. METHODS: All eyes underwent imaging using the Spectralis SD OCT (Heidelberg Engineering GmbH, Heidelberg, Germany), along with IOP measurements and standard automated perimetry (SAP). Glaucoma progression was defined as a result of "Likely Progression" from the Guided Progression Analysis software for SAP. Linear mixed models were used to investigate the relationship between average IOP during follow-up and rates of RNFL thickness change, while taking into account potential confounding factors such as age, race, corneal thickness, and baseline disease severity. MAIN OUTCOME MEASURES: The association between IOP and rates of global and sectorial RNFL thickness loss measured by SD OCT. RESULTS: Forty-six eyes (8.4%) showed progression on SAP during follow-up. Rates of global RNFL thickness change in eyes that progressed by SAP were faster than in those that did not progress (-1.02 vs. -0.61 µm/year, respectively; P = 0.002). For progressing eyes, each 1-mmHg higher average in IOP during follow-up was associated with an additional average loss of 0.20 µm/year (95% confidence interval [CI]: 0.08 to 0.31 µm/year; P < 0.001) of global RNFL thickness versus only 0.04 µm/year (95% CI: 0.01 to 0.07 µm/year; P = 0.015) for nonprogressing eyes. The largest associations between IOP and rates of RNFL change were seen for measurements from the temporal superior and temporal inferior sectors, whereas the smallest association was seen for measurements from the nasal sector. CONCLUSIONS: Higher levels of IOP during follow-up were associated with faster rates of RNFL loss over time measured by SD OCT. These findings support the use of SD OCT RNFL thickness measurements as biomarkers for the evaluation of the efficacy of IOP-lowering therapies to slow down the rate of disease progression.


Assuntos
Glaucoma/diagnóstico , Pressão Intraocular/fisiologia , Fibras Nervosas/patologia , Células Ganglionares da Retina/patologia , Tomografia de Coerência Óptica/métodos , Idoso , Progressão da Doença , Feminino , Seguimentos , Glaucoma/fisiopatologia , Humanos , Masculino , Estudos Prospectivos , Fatores de Tempo , Tonometria Ocular , Testes de Campo Visual , Campos Visuais/fisiologia
3.
Ophthalmology ; 121(2): 498-507, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24289917

RESUMO

PURPOSE: To evaluate the ability of longitudinal frequency doubling technology (FDT) to predict the development of glaucomatous visual field loss on standard automated perimetry (SAP) in glaucoma suspects. DESIGN: Prospective, observational cohort study. PARTICIPANTS: The study included 587 eyes of 367 patients with suspected glaucoma at baseline selected from the Diagnostic Innovations in Glaucoma Study (DIGS) and the African Descent and Glaucoma Evaluation Study (ADAGES). These eyes had an average of 6.7 ± 1.9 FDT tests during a mean follow-up time of 73.1 ± 28.0 months. METHODS: Glaucoma suspects had intraocular pressure (IOP) >21 mmHg or an optic disc appearance suspicious of glaucoma. All patients had normal or nonrepeatable abnormal SAP at baseline. Humphrey Matrix FDT (Carl Zeiss Meditec, Inc, Dublin, CA) testing was performed within 6 months of SAP testing. The study end point was the development of 3 consecutive abnormal SAP test results. Joint longitudinal survival models were used to evaluate the ability of rates of FDT pattern standard deviation (PSD) change to predict the development of visual field loss on SAP, adjusting for confounding variables (baseline age, mean IOP, corneal thickness, and follow-up measurements of SAP PSD). MAIN OUTCOME MEASURES: The R(2) index was used to evaluate and compare the predictive abilities of the model containing longitudinal FDT PSD data with the model containing only baseline data. RESULTS: Sixty-three of 587 eyes (11%) developed SAP visual field loss during follow-up. The mean rate of FDT PSD change in eyes that developed SAP visual field loss was 0.07 dB/year versus 0.02 dB/year in those that did not (P < 0.001). Baseline FDT PSD and slopes of FDT PSD change were significantly predictive of progression, with hazard ratios of 1.11 per 0.1 dB higher (95% confidence interval [CI], 1.04-1.18; P = 0.002) and 4.40 per 0.1 dB/year faster (95% CI, 1.08-17.96; P = 0.04), respectively. The longitudinal model performed significantly better than the baseline model with an R(2) of 82% (95% CI, 74-89) versus 11% (95% CI, 2-24), respectively. CONCLUSIONS: Rates of FDT PSD change were highly predictive of the development of SAP visual field loss in glaucoma suspects. This finding suggests that longitudinal FDT evaluation may be useful for risk stratification of patients with suspected glaucoma.


Assuntos
Hipertensão Ocular/diagnóstico , Transtornos da Visão/diagnóstico , Testes de Campo Visual/métodos , Campos Visuais , Negro ou Afro-Americano , Estudos de Coortes , Progressão da Doença , Feminino , Seguimentos , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Hipertensão Ocular/fisiopatologia , Estudos Prospectivos , Transtornos da Visão/fisiopatologia , Acuidade Visual/fisiologia , População Branca
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA