Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Clin Transl Oncol ; 26(2): 424-433, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37395988

RESUMO

INTRODUCTION: To guarantee treatment reproducibility and stability, immobilization devices are essential. Additionally, surface-guided radiation therapy (SGRT) serves as an accurate complement to frameless stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) by aiding patient positioning and real-time monitoring, especially when non-coplanar fields are in use. At our institute, we have developed a surface-guided SRS (SG-SRS) workflow that incorporates our innovative open-face mask (OM) and mouth bite (MB) to guarantee a precise and accurate dose delivery. METHODS: This study included 40 patients, and all patients were divided into closed mask (CM) and open-face mask (OM) groups according to different positioning flow. Cone beam computed tomography (CBCT) scans were performed, and the registration results were recorded before and after the treatment. Then Bland-Altman method was used to analyze the consistency of AlignRT-guided positioning errors and CBCT scanning results in the OM group. The error changes between 31 fractions in one patient were recorded to evaluate the feasibility of monitoring during treatment. RESULTS: The median of translation error between stages of the AlignRT positioning process was (0.03-0.07) cm, and the median of rotation error was (0.20-0.40)°, which were significantly better than those of the Fraxion positioning process (0.09-0.11) cm and (0.60-0.75)°. The mean bias values between the AlignRT guided positioning errors and CBCT were 0.01 cm, - 0.07 cm, 0.03 cm, - 0.30°, - 0.08° and 0.00°. The 31 inter-fractional errors of a single patient monitored by SGRT were within 0.10 cm and 0.50°. CONCLUSIONS: The application of the SGRT with an innovative open-face mask and mouth bite device could achieve precision positioning accuracy and stability, and the accuracy of the AlignRT system exhibits excellent constancy with the CBCT gold standard. The non-coplanar radiation field monitoring can provide reliable support for motion management in fractional treatment.


Assuntos
Neoplasias Encefálicas , Radiocirurgia , Radioterapia Guiada por Imagem , Humanos , Radiocirurgia/métodos , Posicionamento do Paciente , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/cirurgia , Reprodutibilidade dos Testes , Máscaras , Radioterapia Guiada por Imagem/métodos , Encéfalo , Tomografia Computadorizada de Feixe Cônico/métodos , Planejamento da Radioterapia Assistida por Computador/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA