Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J Pediatr ; 273: 114132, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38823628

RESUMO

OBJECTIVE: To define percentile charts for arterial oxygen saturation (SpO2), heart rate (HR), and cerebral oxygen saturation (crSO2) during the first 15 minutes after birth in neonates born very or extremely preterm and with favorable outcome. STUDY DESIGN: We conducted a secondary-outcome analysis of neonates born preterm included in the Cerebral regional tissue Oxygen Saturation to Guide Oxygen Delivery in preterm neonates during immediate transition after birth III (COSGOD III) trial with visible cerebral oximetry measurements and with favorable outcome, defined as survival without cerebral injuries until term age. We excluded infants with inflammatory morbidities within the first week after birth. SpO2 was obtained by pulse oximetry, and electrocardiogram or pulse oximetry were used for measurement of HR. crSO2 was assessed with near-infrared spectroscopy. Measurements were performed during the first 15 minutes after birth. Percentile charts (10th to 90th centile) were defined for each minute. RESULTS: A total of 207 neonates born preterm with a gestational age of 29.7 (23.9-31.9) weeks and a birth weight of 1200 (378-2320) g were eligible for analyses. The 10th percentile of SpO2 at minute 2, 5, 10, and 15 was 32%, 52%, 83%, and 85%, respectively. The 10th percentile of HR at minute 2, 5, 10, and 15 was 70, 109, 126, and 134 beats/min, respectively. The 10th percentile of crSO2 at minute 2, 5, 20, and 15 was 15%, 27%, 59%, and 63%, respectively. CONCLUSIONS: This study provides new centile charts for SpO2, HR, and crSO2 for neonates born extremely or very preterm with favorable outcome. Implementing these centiles in guiding interventions during the stabilization process after birth might help to more accurately target oxygenation during postnatal transition period.


Assuntos
Frequência Cardíaca , Lactente Extremamente Prematuro , Oximetria , Saturação de Oxigênio , Humanos , Recém-Nascido , Frequência Cardíaca/fisiologia , Saturação de Oxigênio/fisiologia , Feminino , Masculino , Oximetria/métodos , Valores de Referência , Espectroscopia de Luz Próxima ao Infravermelho , Recém-Nascido Prematuro , Oxigênio/metabolismo , Oxigênio/sangue , Encéfalo/metabolismo , Idade Gestacional
2.
J Pediatr ; 246: 40-47.e5, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35257740

RESUMO

OBJECTIVE: To investigate the efficacy and safety of nebulized poractant alfa (at 200 and 400 mg/kg doses) delivered in combination with nasal continuous positive airway pressure compared with nasal continuous positive airway pressure alone in premature infants with diagnosed respiratory distress syndrome. STUDY DESIGN: This randomized, controlled, multinational study was conducted in infants at 280/7 to 326/7 weeks of gestation. The primary outcome was the incidence of respiratory failure in the first 72 hours of life, defined as needing endotracheal surfactant and/or mechanical ventilation owing to prespecified criteria. Secondary outcomes included the time to respiratory failure in the first 72 hours, duration of ventilation, mortality, incidence of bronchopulmonary dysplasia, and major associated neonatal comorbidities. In addition, the safety and tolerability of the treatments were assessed reporting the number and percentage of infants with treatment-emergent adverse events and adverse drug reactions during nebulization. RESULTS: In total, 129 infants were randomized. No significant differences were observed for the primary outcome: 24 (57%), 20 (49%), and 25 (58%) infants received endotracheal surfactant and/or mechanical ventilation within 72 hours in the poractant alfa 200 mg/kg, poractant alfa 400 mg/kg, and nasal continuous positive airway pressure groups, respectively. Similarly, secondary respiratory outcomes did not differ among groups. Enrollment was halted early owing to a change in the benefit-risk balance of the intervention. Nebulized poractant alfa was well-tolerated and safe, and no serious adverse events were related to the study treatment. CONCLUSIONS: The intervention did not decrease the likelihood of respiratory failure within the first 72 hours of life. TRIAL REGISTRATION: ClinicalTrials.gov: NCT03235986.


Assuntos
Doenças do Prematuro , Surfactantes Pulmonares , Síndrome do Desconforto Respiratório do Recém-Nascido , Insuficiência Respiratória , Produtos Biológicos , Pressão Positiva Contínua nas Vias Aéreas , Humanos , Recém-Nascido , Doenças do Prematuro/epidemiologia , Fosfolipídeos , Surfactantes Pulmonares/uso terapêutico , Síndrome do Desconforto Respiratório do Recém-Nascido/tratamento farmacológico , Síndrome do Desconforto Respiratório do Recém-Nascido/epidemiologia , Insuficiência Respiratória/tratamento farmacológico , Tensoativos/uso terapêutico
3.
J Pediatr ; 239: 150-154.e1, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34453917

RESUMO

OBJECTIVE: To characterize respiratory function monitor (RFM) measurements of sustained inflations and intermittent positive pressure ventilation (IPPV) delivered noninvasively to infants in the Sustained Aeration of Infant Lungs (SAIL) trial and to compare vital sign measurements between treatment arms. STUDY DESIGN: We analyzed RFM data from SAIL participants at 5 trial sites. We assessed tidal volumes, rates of airway obstruction, and mask leak among infants allocated to sustained inflations and IPPV, and we compared pulse rate and oxygen saturation measurements between treatment groups. RESULTS: Among 70 SAIL participants (36 sustained inflations, 34 IPPV) with RFM measurements, 40 (57%) were spontaneously breathing prior to the randomized intervention. The median expiratory tidal volume of sustained inflations administered was 5.3 mL/kg (IQR 1.1-9.2). Significant mask leak occurred in 15% and airway obstruction occurred during 17% of sustained inflations. Among 34 control infants, the median expiratory tidal volume of IPPV inflations was 4.3 mL/kg (IQR 1.3-6.6). Mask leak was present in 3%, and airway obstruction was present in 17% of IPPV inflations. There were no significant differences in pulse rate or oxygen saturation measurements between groups at any point during resuscitation. CONCLUSION: Expiratory tidal volumes of sustained inflations and IPPV inflations administered in the SAIL trial were highly variable in both treatment arms. Vital sign values were similar between groups throughout resuscitation. Sustained inflation as operationalized in the SAIL trial was not superior to IPPV to promote lung aeration after birth in this study subgroup. TRIAL REGISTRATION: Clinicaltrials.gov: NCT02139800.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Ventilação com Pressão Positiva Intermitente/métodos , Ressuscitação/métodos , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Feminino , Idade Gestacional , Humanos , Lactente Extremamente Prematuro , Recém-Nascido , Recém-Nascido Prematuro , Ventilação com Pressão Positiva Intermitente/efeitos adversos , Masculino , Testes de Função Respiratória
4.
Clinics (Sao Paulo) ; 71(10): 580-585, 2016 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27759846

RESUMO

OBJECTIVE:: Early diagnosis of significant patent ductus arteriosus reduces the risk of clinical worsening in very low birth weight infants. Echocardiographic patent ductus arteriosus shunt flow pattern can be used to predict significant patent ductus arteriosus. Pulmonary venous flow, expressed as vein velocity time integral, is correlated to ductus arteriosus closure. The aim of this study is to investigate the relationship between significant reductions in vein velocity time integral and non-significant patent ductus arteriosus in the first week of life. METHODS:: A multicenter, prospective, observational study was conducted to evaluate very low birth weight infants (<1500 g) on respiratory support. Echocardiography was used to evaluate vein velocity time integral on days 1 and 4 of life. The relationship between vein velocity time integral and other parameters was studied. RESULTS:: In total, 98 very low birth weight infants on respiratory support were studied. On day 1 of life, vein velocity time integral was similar in patients with open or closed ductus. The mean vein velocity time integral significantly reduced in the first four days of life. On the fourth day of life, there was less of a reduction in patients with patent ductus compared to those with closed patent ductus arteriosus and the difference was significant. CONCLUSIONS:: A significant reduction in vein velocity time integral in the first days of life is associated with ductus closure. This parameter correlates well with other echocardiographic parameters and may aid in the diagnosis and management of patent ductus arteriosus.


Assuntos
Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido de muito Baixo Peso/fisiologia , Veias Pulmonares/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/patologia , Ecocardiografia Doppler/métodos , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Valores de Referência , Fatores de Risco , Estatísticas não Paramétricas , Fatores de Tempo
5.
Clinics ; 71(10): 580-585, Oct. 2016. tab, graf
Artigo em Inglês | LILACS | ID: lil-796867

RESUMO

OBJECTIVE: Early diagnosis of significant patent ductus arteriosus reduces the risk of clinical worsening in very low birth weight infants. Echocardiographic patent ductus arteriosus shunt flow pattern can be used to predict significant patent ductus arteriosus. Pulmonary venous flow, expressed as vein velocity time integral, is correlated to ductus arteriosus closure. The aim of this study is to investigate the relationship between significant reductions in vein velocity time integral and non-significant patent ductus arteriosus in the first week of life. METHODS: A multicenter, prospective, observational study was conducted to evaluate very low birth weight infants (<1500 g) on respiratory support. Echocardiography was used to evaluate vein velocity time integral on days 1 and 4 of life. The relationship between vein velocity time integral and other parameters was studied. RESULTS: In total, 98 very low birth weight infants on respiratory support were studied. On day 1 of life, vein velocity time integral was similar in patients with open or closed ductus. The mean vein velocity time integral significantly reduced in the first four days of life. On the fourth day of life, there was less of a reduction in patients with patent ductus compared to those with closed patent ductus arteriosus and the difference was significant. CONCLUSIONS: A significant reduction in vein velocity time integral in the first days of life is associated with ductus closure. This parameter correlates well with other echocardiographic parameters and may aid in the diagnosis and management of patent ductus arteriosus.


Assuntos
Humanos , Masculino , Feminino , Recém-Nascido , Permeabilidade do Canal Arterial/fisiopatologia , Recém-Nascido de muito Baixo Peso/fisiologia , Veias Pulmonares/fisiopatologia , Velocidade do Fluxo Sanguíneo/fisiologia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/patologia , Ecocardiografia Doppler/métodos , Recém-Nascido Prematuro , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Valores de Referência , Fatores de Risco , Estatísticas não Paramétricas , Fatores de Tempo
6.
J Pediatr ; 167(3): 545-50.e1-2, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26144575

RESUMO

OBJECTIVE: To determine the efficacy and safety of automated adjustment of the fraction of inspired oxygen (FiO2) in maintaining arterial oxygen saturation (SpO2) within a higher (91%-95%) and a lower (89%-93%) target range in preterm infants. STUDY DESIGN: Eighty preterm infants (gestational age [median]: 26 weeks, age [median] 18 days) on noninvasive (n = 50) and invasive (n = 30) respiratory support with supplemental oxygen, were first randomized to one of the SpO2 target ranges and then treated with automated FiO2 (A-FiO2) and manual FiO2 (M-FiO2) oxygen control for 24 hours each, in random sequence. RESULTS: The percent time within the target range was higher during A-FiO2 compared with M-FiO2 control. This effect was more pronounced in the lower SpO2 target range (62 ± 17% vs 54 ± 16%, P < .001) than in the higher SpO2 target range (62 ± 17% vs 58 ± 15%, P < .001). The percent time spent below the target or in hypoxemia (SpO2 <80%) was consistently reduced during A-FiO2, independent of the target range. The time spent above the target range or at extreme hyperoxemia (SpO2 >98%) was only reduced during A-FiO2 when targeting the lower SpO2 range (89%-93%). These outcomes did not differ between infants on noninvasive and invasive respiratory support. Manual adjustments were significantly reduced during A-FiO2 control. CONCLUSIONS: A-FiO2 control improved SpO2 targeting across different SpO2 ranges and reduced hypoxemia in preterm infants on noninvasive and invasive respiratory support. TRIAL REGISTRATION: ISRCTN 56626482.


Assuntos
Oximetria/métodos , Oxigênio/sangue , Respiração Artificial/métodos , Canadá , Estudos Cross-Over , Europa (Continente) , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Masculino , Oxigênio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA