Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Sci Rep ; 9(1): 18403, 2019 12 05.
Artigo em Inglês | MEDLINE | ID: mdl-31804540

RESUMO

The temporomandibular muscle dysfunction is characterized by myofascial pain and is more prevalent in women of reproductive age. Sex steroid hormones are hypothetically involved in the dysfunction, but few are the studies of steroid receptors in masticatory and mastication-related muscles. Our aim was to determine estrogen and testosterone receptor expression in rat masticatory and mastication-related muscles within the context of age and gender. Twelve rats were equally divided into four groups: (a) 10-month-old females; (b) 10-month-old males; (c) 24-month-old females; and (d) 24-month-old males. Euthanasia of the females was performed in the proestrous phase (vaginal smears) and the masticatory and accessory muscles were removed for immunohistochemical analysis. Statistical analysis was performed with ANOVA and the Tukey test. Estrogen receptor expression was similarly low in all muscles and groups. Testosterone receptor expression in the Masseter muscle of the 24-month-old male rats was higher than that in the other groups and significantly superior to its expression in the Posterior Digastric muscle. In short, testosterone receptor expression was highest in old male rats. If we generalize to humans, this fact could indicate age- and sex-related hormonal influence on temporomandibular muscle dysfunction. Further studies, however, are necessary to strengthen this hypothesis.


Assuntos
Envelhecimento/genética , Músculos da Mastigação/metabolismo , Receptores Androgênicos/genética , Receptores de Estrogênio/genética , Animais , Estrogênios/sangue , Feminino , Regulação da Expressão Gênica no Desenvolvimento , Masculino , Mastigação/fisiologia , Músculos da Mastigação/crescimento & desenvolvimento , Proestro/fisiologia , Ratos , Ratos Wistar , Receptores Androgênicos/metabolismo , Receptores de Estrogênio/metabolismo , Transdução de Sinais , Testosterona/sangue
2.
J Esthet Restor Dent ; 28(4): 208-20, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27312653

RESUMO

OBJECTIVE: The aim of this review was to update the literature with regard to the digital methods available by CEREC Chairside system to register and design the occlusion, to report their efficacy and technical innovations in the field of Restorative Dentistry. A search strategy was performed using the key-words: "virtual articulator," or "CAD-CAM and occlusal recording," or "CAD-CAM and occlusion register," or "CAD-CAM and occlusal contacts," or "CAD-CAM and prosthesis." MATERIAL AND METHODS: Inclusion criteria comprised studies evaluating the use of digital methods available by CEREC System for occlusal registration and design during prosthodontics treatment. PubMed and Cochrane library and reference lists were searched up to January 2016. RESULTS: The search resulted in 280 articles after removing duplicates. Subsequently, 233 records were excluded and 49 studies were selected for reading in full. Eleven articles were considered eligible for the systematic review (4 in vitro and 7 clinical studies). CONCLUSION: Scientific evidence suggests that digital methods were accurate to register and design the occlusion of dental prostheses. Nevertheless, further clinical studies are required to establish a conclusion with regard to its accuracy in prosthodontics treatment. CLINICAL SIGNIFICANCE: Digital technologies allow the design of occlusal surfaces of CAD-CAM fabricated prostheses using innovative approaches. This systematic review aimed to update the literature to help dentists determine the most appropriate digital method to register and design the occlusal surface of CAD-CAM crowns. (J Esthet Restor Dent 28:208-220, 2016).


Assuntos
Oclusão Dentária , Restauração Dentária Permanente , Sistemas Automatizados de Assistência Junto ao Leito , Desenho Assistido por Computador , Humanos
3.
Braz Dent J ; 26(5): 458-62, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26647928

RESUMO

Since the dental implant/abutment interface cannot totally seal the passage of microorganisms, the interior of implant becomes a reservoir of pathogenic microorganisms that produce and maintain chronic inflammation in the tissues around implants. Silver nanoparticles (nano-Ag) are potent and broad-spectrum antimicrobial agents. The aim of this study was to evaluate the capacity of the nano-Ag to prevent the contamination of the implant internal surface by Candida albicans, caused by the implant/abutment microgap infiltration. Thirty-six implants were used in this experiment. Three study groups were performed: experimental group (implants receiving an application of nano-Ag in their inner cavity before installation of the abutment); positive-control group (implants receiving sterile phosphate buffer saline application instead of nano-Ag) and negative-control group (implants receiving the application of nano-Ag in the inner cavity and immersed in a sterile medium). In the positive-control and experimental groups, the implants were immersed in a Candida albicans suspension. The abutments of all three groups were screwed with a 10 N torque. After 72 h of immersion inC. albicans suspension or sterile medium, the abutments were removed and the inner surface of the implants was sampled with absorbent paper cone for fungal detection. No C. albicans contamination was observed in the negative-control group. The positive-control group showed statistically higher values of colony forming units (CFUs) of C. albicans compared with the experimental group. In conclusion, silver nanoparticles reduced C. albicans colonization inside the implants, even with low torque screw abutment.


Assuntos
Candida albicans/isolamento & purificação , Implantes Dentários , Nanopartículas Metálicas , Prata/química , Dente Suporte , Técnicas In Vitro
4.
Braz. dent. j ; 26(5): 458-462, Oct. 2015. graf
Artigo em Inglês | LILACS | ID: lil-767624

RESUMO

Abstract: Since the dental implant/abutment interface cannot totally seal the passage of microorganisms, the interior of implant becomes a reservoir of pathogenic microorganisms that produce and maintain chronic inflammation in the tissues around implants. Silver nanoparticles (nano-Ag) are potent and broad-spectrum antimicrobial agents. The aim of this study was to evaluate the capacity of the nano-Ag to prevent the contamination of the implant internal surface byCandida albicans, caused by the implant/abutment microgap infiltration. Thirty-six implants were used in this experiment. Three study groups were performed: experimental group (implants receiving an application of nano-Ag in their inner cavity before installation of the abutment); positive-control group (implants receiving sterile phosphate buffer saline application instead of nano-Ag) and negative-control group (implants receiving the application of nano-Ag in the inner cavity and immersed in a sterile medium). In the positive-control and experimental groups, the implants were immersed in a Candida albicans suspension. The abutments of all three groups were screwed with a 10 N torque. After 72 h of immersion inC. albicans suspension or sterile medium, the abutments were removed and the inner surface of the implants was sampled with absorbent paper cone for fungal detection. No C. albicans contamination was observed in the negative-control group. The positive-control group showed statistically higher values of colony forming units (CFUs) of C. albicans compared with the experimental group. In conclusion, silver nanoparticles reduced C. albicans colonization inside the implants, even with low torque screw abutment.


Resumo: A interface implante/pilar não pode ser totalmente selada para passagem de microrganismos, com isso o interior do implante torna-se um reservatório de microrganismos patogênicos que promovem e mantêm a inflamação crônica nos tecidos em volta dos implantes. Nanopartículas de prata são agentes antimicrobianos potentes e de amplo espectro. O objetivo deste estudo foi avaliar a capacidade das nanopartículas de prata em evitar a contaminação porCandida albicans do interior de implantes, originada da infiltração do fungo através da interface implante/pilar. 36 implantes foram utilizados neste experimento. Três grupos de estudo foram estabelecidos: grupo experimental (os implantes receberam aplicação de nanopartículas de prata na sua cavidade interna, antes da instalação do pilar); grupo controle positivo (os implantes receberam PBS estéril em vez das nanopartículas de prata) e grupo controle negativo (implantes receberam aplicação de nanopartículas de prata na cavidade interna, mas os implantes foram imersos em meio estéril). Nos grupos controle positivo e experimental, os implantes foram imersos em suspensão deCandida albicans. Os pilares protéticos de todos os grupos foram parafusados com torque de 10 N. Após 72 h imersos na suspensão deC. albicans ou em meio estéril, os pilares foram removidos e amostras da superfície interna dos implantes foram coletadas com cone de papel absorvente para a detecção de Candida. No grupo controle negativo não foi observada contaminação por C. albicans. O grupo-controle positivo mostrou valores de unidades formadoras de colônia deCandida estatisticamente maiores quando comparado com o grupo experimental. Conclui-se que nanopartículas de prata reduzem a colonização de C. albicans dentro dos implantes, mesmo quando o pilar é parafusado com torque baixo.


Assuntos
Candida albicans/isolamento & purificação , Implantes Dentários , Nanopartículas Metálicas , Prata/química , Dente Suporte , Técnicas In Vitro
5.
Full dent. sci ; 6(22): 199-205, mar. 2015. ilus
Artigo em Português | LILACS | ID: lil-754385

RESUMO

A interação entre macrófagos e a superfície do implante considera a adsorção de proteínas como primeiro acontecimento no qual determina os processos celulares consequentes e pode ser fulcral para o desenvolvimento de novas estratégias de biocompatibilidade e engenharia de tecidos. Os macrófagos além de participarem do infiltrado inflamatório em reposta durante a implantação no estado inicial da fase inflamatória, onde predominam atividades fagocitárias, também atuam na fase tardia predominante de atividades anti- inflamatórias e reparação tecidual. Eles podem ser identificados na polarização de dois fenótipos diferentes, denominados æÆclássicoÆÆ ativado (M1) ou æÆalternativoÆÆ ativado (M2). São dois subgrupos funcionais os quais apresentam quadros comportamentais inflamatórios e anti-inflamatórios. M2 pode ser ordenado em três subtipos distintos, denominados M2a, M2b e M2c, baseados, sobretudo, nos agentes de indução e expressão do marcador molecular. M2d é resultante de mediadores dependentes da adenosina do macrófago M1, que exibe um padrão de expressão do marcador distinto do IL-4 / IL-13 dependente dos macrófagos M2...


Interaction between macrophages and the implant surface considers protein adsorption as the first event in which the resulting cellular processes are determined and can be crucial for development of new strategies for biocompatibility and tissue engineering. Besides taking participating of the inflammatory infiltrate in response during deployment in the initial stage of the inflammatory phase, in which predominate phagocytic activities, macrophages also act on the predominant late stage of anti-inflammatory activity and tissue repair. They can be identified in two different polarization phenotypes, called ôclassicõ activated (M1) or ôalternativeõ activated (M2), sub-groups with inflammatory and anti-inflammatory functional behavior. M2 can be ordered in three different subtypes, named M2a, M2b, and M2c grounded mainly on inducing agents and expression of molecular marker. M2d results from macrophage mediators of adenosine M1, which exhibits a distinct pattern of expression of marker IL-4 / IL-13 dependent on the M2 macrophages...


Assuntos
Regeneração Óssea , Macrófagos , Monócitos
6.
Int J Biomater ; 2015: 485275, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25667594

RESUMO

Silver has been used in medicine for centuries because of its antimicrobial properties. More recently, silver nanoparticles have been synthesized and incorporated into several biomaterials, since their small size provides great antimicrobial effect, at low filler level. Hence, these nanoparticles have been applied in dentistry, in order to prevent or reduce biofilm formation over dental materials surfaces. This review aims to discuss the current progress in this field, highlighting aspects regarding silver nanoparticles incorporation, such as antimicrobial potential, mechanical properties, cytotoxicity, and long-term effectiveness. We also emphasize the need for more studies to determine the optimal concentration of silver nanoparticle and its release over time.

7.
Int J Pediatr Otorhinolaryngol ; 77(4): 519-24, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23312530

RESUMO

OBJECTIVES: To compare the prevalence of signs and symptoms of temporomandibular dysfunction (TMD) in female adolescent athletes and non-athletes and to examine the association between signs and symptoms of TMD in female adolescents in different Tanner stages. METHODS: The subjects were 89 female basketball and handball players ages 10-18 years and 72 female non-athlete adolescents ages 10-19 years selected from the Department of Pediatrics (School of Medicine, Federal University of São Paulo) as a control group. A survey was used to assess the signs and symptoms of TMD. According to the answers on the survey the adolescents were classified in two categories: no signs or symptoms present (score A-absent), at least one sign or symptom present (score P-present). The ones who got score "P" were submitted to a standardized functional examination of the masticatory system by four previously calibrated examiners. Pubertal status was assessed based on physical examination by physicians from our Division. The adolescents were classified according to Tanner stages into three subgroups: subgroup 1 (before the growth spurt), subgroup 2 (growth spurt period), subgroup 3 (end of growth spurt). Significant differences between athletes and non-athletes were assessed for categorical variables (Chi-square and Fisher's exact test) and for continuous variables (Mann-Whitney test). The level of significance used was 5%. There was significant agreement between raters, kappa-values (0.621-1.000) and ICC values (0.757-0.899). RESULTS: There was no significant difference between the athletes and non-athletes in exhibiting at least one sign or symptom of TMD (p=0.301). When comparing the adolescents who presented at least one symptom of TMD to the different subgroups of Tanner stages no statistically significant differences were found (p=0.124). CONCLUSION: The lack of significant differences among female adolescent athletes and non-athletes and among the subgroups of Tanner stages may suggests that although contact sports increase the risk of temporomandibular joint lesions and estrogen levels are risk factor for onset of TMD, they do not impact significantly on the onset of this disorder, when considered alone.


Assuntos
Atletas , Transtornos da Articulação Temporomandibular/diagnóstico , Transtornos da Articulação Temporomandibular/epidemiologia , Articulação Temporomandibular/fisiopatologia , Adolescente , Criança , Feminino , Inquéritos Epidemiológicos , Humanos , Prevalência , Puberdade , Fatores de Risco , Adulto Jovem
8.
Braz. dent. j ; 23(5): 502-507, Sept.-Oct. 2012. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-660351

RESUMO

The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.


O presente estudo avaliou a intercambiabilidade dos componentes protéticos de implantes de hexágono externo medindo-se a precisão da interface implante/pilar com microscopia eletrônica de varredura. Foram utilizados dez implantes para cada uma de três marcas (SIN, Conexão, Neodent) com seus respectivos pilares (base metálica de CoCr , rotacional e não rotacional) e um de marca alternativa (Microplant) em um arranjo com todas as combinações de implante/pilar possíveis. O valor de referência para a intercambiabilidade das várias marcas de componentes foi definido pela diferença do pilar original para com seu respectivo implante. Dessa maneira, a intercambiabilidade foi considerada válida quando o resultado para um dado pilar colocado sobre um implante fosse igual ou menor que a diferença medida quando o pilar da mesma marca do implante fora posicionado. Os dados foram comparados pelo teste de Kruskal-Wallis com nível de significância de 5%. Um grau de desajuste foi observado em todos os espécimes. De uma maneira geral, o pilar anti-rotacional foi mais preciso do que o rotacional. Estes variaram de 0,6-16,9 µm, com mediana 4,6 µm; enquanto o anti-rotacional foi de 0,3-12,9 µm, com mediana de 3,4 µm. Os espécimes com o pilar e o implante Conexão tiveram uma diferença maior que o conjunto original para SIN e Neodent (p<0,05). Apesar destes últimos apresentarem resultados semelhantes com seus respectivos pilares, quando trocados não mantiveram a mesma precisão original. Os resultados sugerem que a marca alternativa seria a única que apresentaria compatibilidade com todos os sistemas, enquanto as outras marcas não seriam completamente intercambiáveis.


Assuntos
Ligas de Cromo/química , Projeto do Implante Dentário-Pivô/métodos , Implantes Dentários/normas , Ajuste de Prótese/métodos , Projeto do Implante Dentário-Pivô/instrumentação , Microscopia Eletrônica de Varredura
9.
Braz Dent J ; 23(5): 502-7, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23306225

RESUMO

The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.


Assuntos
Ligas de Cromo/química , Projeto do Implante Dentário-Pivô/métodos , Implantes Dentários/normas , Ajuste de Prótese/métodos , Projeto do Implante Dentário-Pivô/instrumentação , Microscopia Eletrônica de Varredura
10.
Artigo em Inglês, Espanhol, Português | VETINDEX | ID: biblio-1480880

RESUMO

Os dentes caninos, o quarto pré-molar superior, seguidos por pré-molares, molares e incisivos, são os mais acometidos por fratura. Quando há exposição pulpar, são tratados endodonticamente e restaurados. Para os dentes com grande destruição coronária, indica-se reconstrução protética coronal com metal fundido, que recebe o nome de restauração metálica fundida (RMF) e recobre toda a superfície da coroa clínica. Tais restaurações utilizam retentores intrarradiculares com núcleo e ferulação (cintamento). O retentor intrarradicular serve para aumentar a retentividade do conjunto. A base do núcleo é a estrutura do espelho, que apoia-se no remanescente coronal, sendo protegida pela férula (ou cintamento), que promove um abraçamento cervicocoronal e aumenta a resistência a possíveis novas fraturas. A ação protetora do espelho e da férula associados neutralizará o efeito de cunha causado pelos pinos intrarradiculares.


The most often fractured teeth are the upper canines, fourth pre-molars (carnassial teeth), pre-molars and incisors. In cases of pulp exposure, the animals undergo endodontic treatment and subsequent restoration of the broken tooth. When there is extensive coronal destruction, metallic coronal prostheses with molten metal, which are often called full cast metal restorations, are indicated. These cover the whole surface of the clinical crown and often make use of a cast post and core with a ferrule (crown bracing). This kind of technique improves the stability of the restoration. The mirror structure forms the base of the core, which leans on the remainder of the crown and is protected by the ferrule, which, in turn, promotes a cervico-coronal bracing that increases the resistance to new fractures. The protective effect of the association of mirror and ferrule will neutralize the bevel effect caused by the metallic post.


Los caninos, cuarto premolar superior y los premolares, molares e incisivos, son los dientes con mayor incidencia de fracturas en el perro. En los casos en que hay exposición de la pulpa, se realiza un tratamiento de endodoncia. En dientes con una gran destrucción coronaria, se indica una restauración protésica coronal con metal fundido, que normalmente es llamada restauración metálica fundida (RMF), que recubre la totalidad de la superficie de la corona. Estas restauraciones requieren de retenedores intrarradiculares con núcleo y ferulización (abrazamiento cervical). El retenedor intrarradicular sirve para aumentar la estabilidad del conjunto. La base del núcleo es la estructura “en espejo” que se apoya en el resto de la corona, que está protegida por la férula (o abrazo). Esto induce un “abrazo cérvico coronal” aumentando la resistencia a nuevas fracturas. La acción protectora asociada del espejo y de la férula, neutraliza el efecto de cuña causado por los pernos intrarradiculares.


Assuntos
Animais , Ferula , Pinos Ortopédicos , Cães/classificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA