Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-36078742

RESUMO

This paper analyzes the reliability and usability of a portable electronic instrument that measures balance and balance impairment in older adults. The center of pressure (CoP) metrics are measured with a modified Wii Balance Board (mWBB) platform. In the intra- and inter-rater testing, 16 and 43 volunteers (mean 75.66 and standard deviation (SD) of 7.86 years and 72.61 (SD 7.86) years, respectively) collaborated. Five volunteer raters (5.1 (SD 3.69) years of experience) answered the System Usability Scale (SUS). The most reliable CoP index in the intra-examiner tests was the 95% power frequency in the medial-lateral displacement of the CoP with closed-eyes. It had excellent reliability with an intraclass correlation coefficient ICC = 0.948 (C.I. 0.862-0.982) and a Pearson's correlation coefficient PCC = 0.966 (p < 0.001). The best index for the inter-rater reliability was the centroidal frequency in the anterior-posterior direction closed-eyes, which had an ICC (2,1) = 0.825. The mWBB also obtained a high usability score. These results support the mWBB as a reliable complementary tool for measuring balance in older adults. Additionally, it does not have the limitations of laboratory-grade systems and clinical screening instruments.


Assuntos
Equilíbrio Postural , Jogos de Vídeo , Idoso , Humanos , Reprodutibilidade dos Testes
2.
PLoS One ; 16(8): e0256129, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34398918

RESUMO

BACKGROUND: The timely detection of fall risk or balance impairment in older adults is transcendental because, based on a reliable diagnosis, clinical actions can be taken to prevent accidents. This study presents a statistical model to estimate the fall risk from the center of pressure (CoP) data. METHODS: This study is a cross-sectional analysis from a cohort of community-dwelling older adults aged 60 and over living in Mexico City. CoP balance assessments were conducted in 414 older adults (72.2% females) with a mean age of 70.23 ± 6.68, using a modified and previously validated Wii Balance Board (MWBB) platform. From this information, 78 CoP indexes were calculated and analyzed. Multiple logistic regression models were fitted in order to estimate the relationship between balance alteration and the CoP indexes and other covariables. RESULTS: The CoP velocity index in the Antero-Posterior direction with open eyes (MVELAPOE) had the best value of area under the curve (AUC) to identify a balance alteration (0.714), and in the adjusted model, AUC was increased to 0.827. Older adults with their mean velocity higher than 14.24 mm/s had more risk of presenting a balance alteration than those below this value (OR (Odd Ratio) = 2.94, p<0.001, 95% C.I.(Confidence Interval) 1.68-5.15). Individuals with increased age and BMI were more likely to present a balance alteration (OR 1.17, p<0.001, 95% C.I. 1.12-1.23; OR 1.17, p<0.001, 95% C.I. 1.10-1.25). Contrary to what is reported in the literature, sex was not associated with presenting a balance alteration (p = 0.441, 95% C.I. 0.70-2.27). SIGNIFICANCE: The proposed model had a discriminatory capacity higher than those estimated by similar means and resources to this research and was implemented in an embedded standalone system which is low-cost, portable, and easy-to-use, ideal for non-laboratory environments. The authors recommend using this technology to support and complement the clinical tools to attend to the serious public health problem represented by falls in older adults.


Assuntos
Avaliação Geriátrica/métodos , Aptidão Física/fisiologia , Equilíbrio Postural/fisiologia , Jogos de Vídeo , Idoso , Área Sob a Curva , Estudos Transversais , Feminino , Humanos , Vida Independente , Masculino , México , Pressão
3.
Ann Biomed Eng ; 49(2): 933-945, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33009606

RESUMO

This work presents the design and development of a new alternative tool to measure the Center of Pressure (CoP) displacements, intended to evaluate the human balance. The device is based on a modified commercial balance board used for video games, resulting in a low-cost, portable device capable of computing the CoP, providing 24 of the most used indexes to test the human balance. The proposed standalone device runs on rechargeable batteries, weighs only 3.5 kg, and has a data storage capacity for over 1000 tests. Visual and auditory instructions assist its user interface. Thus, contrary to the commercial systems designed for laboratory use, this device enables the measurement of quantitative balance parameters in non-laboratory places, allowing the study of the balance of vulnerable populations directly on their typical environments. To evaluate the device, 20 older adults (68.60 ± 1.23 years) were tested, and the resulting values were compared with a similar study using a force platform; 19 indexes showed a similarity with those reported using force platform and 12 of these were statistically equivalent. The proposed device represents an open-source alternative tool for researchers and healthcare personnel to acquire reliable data to evaluate human balance.


Assuntos
Monitorização Ambulatorial/instrumentação , Equilíbrio Postural , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos
4.
Micromachines (Basel) ; 13(1)2021 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-35056201

RESUMO

Pulse Width Modulation (PWM) strategies are crucial for controlling DC-AC power converters. In particular, transformerless inverters require specific PWM techniques to improve efficiency and to deal with leakage ground current issues. In this paper, three hybrid PWM methods are proposed for a DCM-232 three-phase topology. These methods are based on the concepts of carrier-based PWM and space vector modulation. Calculations of time intervals for active and null vectors are performed in a conventional way, and the resulting waveforms are compared with a carrier signal. The digital signals obtained are processed using Boolean functions, generating ten signals to control the DCM-232 three-phase inverter. The performance of the three proposed PWM methods is evaluated considering the reduction in leakage ground current and efficiency. The proposed modulation techniques have relevant performances complying with international standards, which make them suitable for transformerless three-phase photovoltaic (PV) inverter markets. To validate the proposed hybrid PWM strategies, numerical simulations and experimental tests were performed.

5.
Biomed Phys Eng Express ; 6(1): 015027, 2020 01 20.
Artigo em Inglês | MEDLINE | ID: mdl-33438615

RESUMO

OBJECTIVE: This paper presents the design and development of a new electronic portable device to assess the human balance of the human body during standing, using a minimal number of sensors and peripheral components. This device is aimed to evaluate human balance in environments outside of specialized laboratories, such as small clinics and therapy offices. APPROACH: The design is based on previous designs using three or more resistive force sensors attached to the feet, however in the present work, the sensors were attached on an adjustable platform, to fit several sizes of feet. Furthermore, all the signal acquisition, process, storage and display are executed by an embedded electronic system, thus avoiding the use of computers and external peripherals. A new method to compute the CoP using only two sensors per foot was developed and tested in a group of 50 university students, (17 women and 33 men), 26.04 ± 4.94 years. MAIN RESULTS: It was developed a portable electronic system to measure the trajectory of the CoP and to calculate the indexes values derived from it. The system is capable to discriminate between measuring situations (open and closed eyes), using only two sensors per foot (p < 0.0001). A comparison between the values obtained for young subjects using the proposed device, and the values reported in the literature showed a similar tendency. SIGNIFICANCE: The results indicate that the proposed system is a good, low-cost, and easy-to-use alternative tool for researchers and clinicians interested in the evaluation of human balance, especially if the measurements must be done outside laboratories.


Assuntos
Técnicas Biossensoriais/métodos , Diagnóstico por Computador/métodos , Eletrônica/instrumentação , Pé/fisiologia , Equilíbrio Postural/fisiologia , Adulto , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA