RESUMO
INTRODUCTION: The number of patients who have a cardiac implantable electronic device (CIEDs) that undergo a course of radiotherapy is increasing due to the ageing population. The majority of clinical studies only evaluate any CIED malfunction at the end of a course of irradiation or in a case of there being symptoms of possible malfunction. As a result, little data has been collected on CIED status acquired during an active course of irradiation. MATERIAL AND METHODS: We aimed to evaluate the correct functioning of a CIED during a course of radiotherapy. So, a retrospective analysis was made of all patients having CIEDS in a single institution during their course of radiotherapy. All CIEDs were systematically checked before and during the course of radiotherapy according to the risk of device failure and patient dependence. RESULTS: Data was analysed from 56 patients (43 men, 13 women) with a mean age of 78.2 years, of whom 87.5% of the patients carried a pacemaker (PM), the 39% of the patients were PM dependent, and the remaining patients carried an implantable cardioverter-defibrillator (ICD). An observable dose of irradiation was evident in only 10 cases. 69.1% of the CIEDs were checked daily and the remainder were checked weekly. During the radiotherapy course, 82% of the patients did not complain of any cardiological event. The CIED of five patients experienced an increase in the threshold and, in another case, a sudden reduction in the duration of the battery was reported. Another patient with a CIED experienced a cardiac insufficiency episode triggered by a ventricular tachycardia. CONCLUSION: In conclusions, although adverse clinical events from exposure of a CIED to irradiation are rare, they can appear in any group of risk. No dose-dependency was observed on the malfunction of the CIED.