RESUMO

Fecal Immunochemical Test (FIT) followed by a colonoscopy is an efficacious strategy to improve the adenoma detection rate and Colorectal Cancer (CRC). There is no organized national screening program for CRC in Brazil. The aim of this research was to describe the implementation of an organized screening program for CRC through FIT followed by colonoscopy, in an urban low-income community of São Paulo city. The endpoints of the study were: FIT participation rate, FIT positivity rate, colonoscopy compliance rate, Positive Predictive Values (PPV) for adenoma and CRC, and the rate of complications. From May 2016 to October 2019, asymptomatic individuals, 50-75 years old, received a free kit to perform the FIT. Positive FIT (≥ 50 ng/mL) individuals were referred to colonoscopy. 10,057 individuals returned the stool sample for analysis, of which (98.2%) 9,881 were valid. Women represented 64.8% of the participants. 55.3% of individuals did not complete elementary school. Positive FIT was 7.8% (776/9881). The colonoscopy compliance rate was 68.9% (535/776). There were no major colonoscopy complications. Adenoma were detected in 63.2% (332/525) of individuals. Advanced adenomatous lesions were found in 31.4% (165/525). CRC was diagnosed in 5.9% (31/525), characterized as adenocarcinoma: in situ in 3.2% (1/31), intramucosal in 29% (9/31), and invasive in 67.7% (21/31). Endoscopic treatment with curative intent for CRC was performed in 45.2% (14/31) of the cases. Therefore, in an urban low-income community, an organized CRC screening using FIT followed by colonoscopy ensued a high participation rate, and high predictive positive value for both, adenoma and CRC.


Assuntos
Colonoscopia , Neoplasias Colorretais , Detecção Precoce de Câncer , Sangue Oculto , Idoso , Feminino , Humanos , Pessoa de Meia-Idade , Adenocarcinoma/diagnóstico , Adenocarcinoma/cirurgia , Brasil , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/cirurgia , Adenoma/diagnóstico , Adenoma/cirurgia , Masculino
2.
Clinics ; 78: 100278, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1520689

RESUMO

Abstract Fecal Immunochemical Test (FIT) followed by a colonoscopy is an efficacious strategy to improve the adenoma detection rate and Colorectal Cancer (CRC). There is no organized national screening program for CRC in Brazil. The aim of this research was to describe the implementation of an organized screening program for CRC through FIT followed by colonoscopy, in an urban low-income community of São Paulo city. The endpoints of the study were: FIT participation rate, FIT positivity rate, colonoscopy compliance rate, Positive Predictive Values (PPV) for adenoma and CRC, and the rate of complications. From May 2016 to October 2019, asymptomatic individuals, 50-75 years old, received a free kit to perform the FIT. Positive FIT (≥ 50 ng/mL) individuals were referred to colonoscopy. 10,057 individuals returned the stool sample for analysis, of which (98.2%) 9,881 were valid. Women represented 64.8% of the participants. 55.3% of individuals did not complete elementary school. Positive FIT was 7.8% (776/9881). The colonoscopy compliance rate was 68.9% (535/776). There were no major colonoscopy complications. Adenoma were detected in 63.2% (332/525) of individuals. Advanced adenomatous lesions were found in 31.4% (165/525). CRC was diagnosed in 5.9% (31/525), characterized as adenocarcinoma: in situ in 3.2% (1/31), intramucosal in 29% (9/31), and invasive in 67.7% (21/31). Endoscopic treatment with curative intent for CRC was performed in 45.2% (14/31) of the cases. Therefore, in an urban low-income community, an organized CRC screening using FIT followed by colonoscopy ensued a high participation rate, and high predictive positive value for both, adenoma and CRC.

3.
Arq Gastroenterol ; 57(3): 316-322, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32935747

RESUMO

BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.


Assuntos
Adenoma , Neoplasias Colorretais , Adenoma/diagnóstico , Idoso , Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer , Fezes , Humanos , Pessoa de Meia-Idade , Sangue Oculto
4.
Arq. gastroenterol ; 57(3): 316-322, July-Sept. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131664

RESUMO

ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.


RESUMO CONTEXTO: Sangramento retal é o sintoma mais importante de neoplasia intestinal; portanto, testes para detecção de sangue oculto nas fezes são amplamente usados para rastreamento de lesões pré-neoplásicas e de câncer colorretal (CCR). OBJETIVO: Avaliar a acurácia do teste quantitativo OC-Sensor (Eiken Chemical, Tokyo, Japan) com o valor de corte de 10 µg Hb/g fezes (50 ng/mL) numa coorte de indivíduos que se submeteram à colonoscopia diagnóstica, e se mais de uma amostra coletada em dias consecutivos melhoraria a acurácia diagnóstica do teste. MÉTODOS: Pacientes (idade média 56,3±9,7 anos) que se submeteram à colonoscopia prospectivamente, randomicamente, receberam tubos de coleta: um (1-amostra FIT, FIT 1), ou dois (2-amostra FIT, FIT 2). Eles coletaram as amostras de fezes antes de iniciar o preparo da colonoscopia. As amostras foram analisadas pelo OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). As performances do FIT 1 e do FIT 2 foram comparadas com os achados da colonoscopia. RESULTADOS: Entre 289 pacientes, CCR foi diagnosticado em 14 (4,8%), adenoma avançado em 37 (12,8%), adenoma precoce em 71 (24,6%) e sem anormalidades em 141 (48,8%). Para FIT 1, a sensibilidade para CCR foi 83,3% (95%IC 36,5-99,1%), para adenoma avançado foi 24% (95%IC 10,1-45,5%), com especificidade de 86,9% (95%IC 77,3-92,9%). Para FIT 2, a sensibilidade para CCR foi 75% (95%IC 35,6-95,5%), para adenoma avançado foi 50% (95%IC 22,3-77,7%), com especificidade de 92,9% (95%IC 82,2-97,7%). A razão de verossimilhança positiva foi 1,8 (95%IC 0,7-4,4 para FIT 1) e 7,1 (95%IC 2,4-21,4 para FIT 2) para adenoma avançado, e 6,4 (95%IC 3,3-12,3, para FIT 1) e 10,7 (95%IC 3,8-29,8, para FIT 2) para CCR. A razão de verossimilhança negativa foi 0,9 (95%IC 0,7-1, para FIT 1) e 0,5 (95%IC 0,3-0,9, para FIT 2) para adenoma avançado, e 0,2 (0,03-1,1, para FIT 1) e 0,3 (0,08-0,9, para FIT 2) para CCR. As diferenças de performance entre FIT 1 e FIT 2 não foram significantes. Entretanto, a comparação dos níveis de hemoglobina nas fezes dos pacientes de FIT 1 e FIT 2 mostraram que as diferenças entre sem pólipo e adenoma avançado e CCR foram significantes. CONCLUSÃO: A acurácia do OCR Sensor com valor de corte de 10 µg Hb/g de fezes foi comparável a outras publicações e a coleta de duas amostras melhorou a taxa de detecção de adenoma avançado, lesão pré-neoplásica, para prevenir CCR.


Assuntos
Humanos , Idoso , Neoplasias Colorretais/diagnóstico , Adenoma , Colonoscopia , Detecção Precoce de Câncer , Fezes , Pessoa de Meia-Idade , Sangue Oculto
5.
Arq Gastroenterol ; 57(2): 154-160, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32609157

RESUMO

BACKGROUND: It has been proposed that the combination of gastrin-17 (G-17), pepsinogens I and II (PGI and PGII), and anti-Helicobacter pylori (H. pylori) antibodies (GastroPanel®, BIOHIT HealthCare, Helsinki, Finland) could serve as biomarkers of atrophic gastritis. OBJECTIVE: This study aimed to ensure the diagnostic accuracy of GastroPanel® and evaluate the effect of proton pump inhibitors (PPIs) on these biomarkers. METHODS: Dyspeptic patients who underwent gastrointestinal endoscopy were enrolled in the present study. Histological findings, which were the gold standard to stratify groups, were as follows: no atrophy (controls); antrum atrophy; corpus atrophy; multifocal atrophy; and neoplasia. G-17, PGI, PGII, and anti-H. pylori immunoglobulin (Ig)G antibodies were assayed using commercially available kits. The ratio of PGI/PGII was calculated. RESULTS: Among 308 patients, 159 (51.6%) were PPI users. The overall prevalence of atrophy was 43.8% (n=135). Ninety-two (29.9%) patients were H. pylori positive according to anti-H. pylori IgG levels. G-17 levels were not low in those with antrum atrophy but were high in those with corpus and multifocal atrophies. PGI levels were significantly lower in those with corpus and multifocal atrophies. The sensitivity of PGI <30 µg/L to detect corpus atrophy was 50% (95% CI 27.8-72.1%), with a specificity of 93.2% (95% CI 84.3-97.5%), a positive likelihood ratio of 7.4 (95% CI 2.9-19.2), and a negative likelihood ratio of 0.5 (95% CI 0.3-0.8). A small number of subjects (n=6) exhibited moderate to intense atrophy (4%), among whom 66.7% exhibited decreased PGI levels. PPI significantly increased the levels of G-17 and PGI, except in those with corpus and multifocal atrophies, in whom PGI levels were not increased by PPIs. CONCLUSION: GastroPanel® (Gastrin-17, PGI, and PGI/PGII ratio) did not demonstrate high sensitivity for detecting gastric atrophy.


Assuntos
Gastrite Atrófica/diagnóstico , Inibidores da Bomba de Prótons , Anticorpos Antibacterianos , Brasil , Infecções por Helicobacter , Helicobacter pylori , Humanos
7.
Arq. gastroenterol ; 57(2): 154-160, Apr.-June 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131649

RESUMO

ABSTRACT BACKGROUND: It has been proposed that the combination of gastrin-17 (G-17), pepsinogens I and II (PGI and PGII), and anti-Helicobacter pylori (H. pylori) antibodies (GastroPanel®, BIOHIT HealthCare, Helsinki, Finland) could serve as biomarkers of atrophic gastritis. OBJECTIVE: This study aimed to ensure the diagnostic accuracy of GastroPanel® and evaluate the effect of proton pump inhibitors (PPIs) on these biomarkers. METHODS: Dyspeptic patients who underwent gastrointestinal endoscopy were enrolled in the present study. Histological findings, which were the gold standard to stratify groups, were as follows: no atrophy (controls); antrum atrophy; corpus atrophy; multifocal atrophy; and neoplasia. G-17, PGI, PGII, and anti-H. pylori immunoglobulin (Ig)G antibodies were assayed using commercially available kits. The ratio of PGI/PGII was calculated. RESULTS: Among 308 patients, 159 (51.6%) were PPI users. The overall prevalence of atrophy was 43.8% (n=135). Ninety-two (29.9%) patients were H. pylori positive according to anti-H. pylori IgG levels. G-17 levels were not low in those with antrum atrophy but were high in those with corpus and multifocal atrophies. PGI levels were significantly lower in those with corpus and multifocal atrophies. The sensitivity of PGI <30 µg/L to detect corpus atrophy was 50% (95% CI 27.8-72.1%), with a specificity of 93.2% (95% CI 84.3-97.5%), a positive likelihood ratio of 7.4 (95% CI 2.9-19.2), and a negative likelihood ratio of 0.5 (95% CI 0.3-0.8). A small number of subjects (n=6) exhibited moderate to intense atrophy (4%), among whom 66.7% exhibited decreased PGI levels. PPI significantly increased the levels of G-17 and PGI, except in those with corpus and multifocal atrophies, in whom PGI levels were not increased by PPIs. CONCLUSION: GastroPanel® (Gastrin-17, PGI, and PGI/PGII ratio) did not demonstrate high sensitivity for detecting gastric atrophy.


RESUMO CONTEXTO: Foi proposto que a combinação de gastrina 17 (G-17), pepsinogênios I e II (PGI e PGII), e anticorpos anti-Helicobacter pylori (H. pylori) (GastroPanel®, BIOHIT HealthCare), poderiam indicar gastrite atrófica. OBJETIVO: Portanto, o objetivo foi averiguar a acurácia diagnóstica do painel gástrico e avaliar o efeito dos inibidores de bomba de prótons (IBP) nesses marcadores. MÉTODOS: Pacientes dispépticos que se submeteram à endoscopia gastrointestinal entraram no estudo. Os achados histológicos foram o padrão ouro para estratificar os grupos: sem atrofia (controles), atrofia de antro, atrofia de corpo, atrofia multifocal e neoplasia. G-17, PGI, PGII, e anticorpos IgG anti-H. pylori foram determinados por kits comerciais. A razão PGI/PGII foi calculada. RESULTADOS: Entre 308 pacientes que foram incluídos, 159 estavam usando IBP (51,6%). A prevalência de atrofia foi de 43,8% (135 pacientes). H. pylori foi positivo em 92 (29,9%) pacientes por IgG anti-H. pylori. G-17 não estava diminuída na atrofia do antro, mas estava elevada nas atrofias do corpo e multifocal. PGI estava significantemente menor nas atrofias de corpo e multifocal. A sensibilidade da PGI <30 µg/L de indicar atrofia do corpo foi 50% (95%IC 27,8-72,1%) com especificidade de 93,2% (95%IC 84,3-97,5%), razão de verossimilhança positiva de 7,4 (95%IC 2,9-19,2) e razão de verossimilhança negativa de 0,5 (95%IC 0,3-0,8). O número de indivíduos com atrofia moderada para intensa foi pequeno (n=6;4%), dos quais 66,7% tinham diminuição dos níveis de PGI. IBP significantemente aumentou os níveis de G-17 e PGI, exceto nas atrofias de corpo e multifocal que não apresentaram aumento de PGI. CONCLUSÃO: O painel gástrico não teve alta sensibilidade de indicar gastrite atrófica.


Assuntos
Humanos , Inibidores da Bomba de Prótons , Gastrite Atrófica/diagnóstico , Brasil , Helicobacter pylori , Infecções por Helicobacter , Anticorpos Antibacterianos
9.
Arq Gastroenterol ; 55(2): 128-132, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30043860

RESUMO

BACKGROUND: Colorectal bleeding is a warning sign that may be identified by fecal occult blood testing. A positive fecal occult blood test result requires a subsequent colonoscopy, a costly and invasive examination. Therefore, the use of diagnostic tests with optimal sensitivity and specificity is warranted. In this study, we evaluated four different fecal occult blood tests in 176 patients undergoing colonoscopy and compared their results. OBJECTIVE: To assess the sensitivity, specificity and predictive values of chemical and immunochemical fecal occult blood tests in patients undergoing colonoscopy and to evaluate the degree of concordance between the tests and colonoscopy. METHODS: Patients with indications for colonoscopy also underwent fecal occult blood testing by chemical (toluidine test) and immunochemical methods, employing three commercially available kits. Based on the endoscopic findings, the colonoscopy was rated as positive or negative for colorectal bleeding. The degree of concordance between the fecal occult blood tests and the colonoscopy was evaluated by the kappa index. RESULTS: Forty-four (25%) colonoscopies were categorized as positive for colorectal bleeding. The toluidine test presented lower concordance than the immunochemical tests, which showed moderate concordance with the colonoscopy. The toluidine test had the least sensitivity, specificity, and positive and negative predictive values. CONCLUSION: The immunochemical fecal occult blood tests showed greater sensitivity, specificity and predictive values in detecting colorectal bleeding. The immunochemical tests had superior indexes of agreement with colonoscopy compared to the toluidine test.


Assuntos
Colonoscopia/normas , Neoplasias Colorretais/diagnóstico , Fezes/química , Sangue Oculto , Toluidinas/análise , Adolescente , Adulto , Detecção Precoce de Câncer , Feminino , Humanos , Imuno-Histoquímica , Masculino , Programas de Rastreamento , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Adulto Jovem
10.
Arq. gastroenterol ; 55(2): 128-132, Apr.-June 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-950517

RESUMO

ABSTRACT BACKGROUND: Colorectal bleeding is a warning sign that may be identified by fecal occult blood testing. A positive fecal occult blood test result requires a subsequent colonoscopy, a costly and invasive examination. Therefore, the use of diagnostic tests with optimal sensitivity and specificity is warranted. In this study, we evaluated four different fecal occult blood tests in 176 patients undergoing colonoscopy and compared their results. OBJECTIVE: To assess the sensitivity, specificity and predictive values of chemical and immunochemical fecal occult blood tests in patients undergoing colonoscopy and to evaluate the degree of concordance between the tests and colonoscopy. METHODS: Patients with indications for colonoscopy also underwent fecal occult blood testing by chemical (toluidine test) and immunochemical methods, employing three commercially available kits. Based on the endoscopic findings, the colonoscopy was rated as positive or negative for colorectal bleeding. The degree of concordance between the fecal occult blood tests and the colonoscopy was evaluated by the kappa index. RESULTS: Forty-four (25%) colonoscopies were categorized as positive for colorectal bleeding. The toluidine test presented lower concordance than the immunochemical tests, which showed moderate concordance with the colonoscopy. The toluidine test had the least sensitivity, specificity, and positive and negative predictive values. CONCLUSION: The immunochemical fecal occult blood tests showed greater sensitivity, specificity and predictive values in detecting colorectal bleeding. The immunochemical tests had superior indexes of agreement with colonoscopy compared to the toluidine test.


RESUMO CONTEXTO: O sangramento colorretal é considerado um sinal de alarme e não deve ser ignorado. O resultado positivo de um teste de pesquisa de sangue oculto nas fezes (PSOF) requer investigação complementar com colonoscopia, exame invasivo e de alto custo. Justifica-se, portanto, a aplicação de um teste diagnóstico mais sensível e específico. No presente estudo, foram avaliados quatro diferentes testes de PSOF em 176 pacientes submetidos à colonoscopia e seus resultados foram comparados. OBJETIVO: Avaliar a sensibilidade, a especificidade e os valores de predição dos testes químico e imunoquímico de PSOF em pacientes submetidos à colonoscopia e avaliar o grau de concordância entre os testes de PSOF e a colonoscopia. MÉTODOS: Pacientes com indicação de realizar colonoscopia foram submetidos também à PSOF pelo método químico (o-toluidina) e pelo método imunoquímico, empregando três kits comerciais disponíveis no mercado. Fundamentado nos achados endoscópicos, a colonoscopia foi categorizada em positiva ou negativa, de acordo com a possível fonte de sangramento colorretal. O grau de concordância entre os testes de PSOF foi avaliado pelo índice kappa. RESULTADOS: Quarenta e quatro (25%) colonoscopias foram categorizadas como positivas quanto à fonte de sangramento colorretal. O teste da o-toluidina mostrou menor concordância que os testes imunoquímicos, os quais apresentaram moderada concordância com a colonoscopia. O teste da o-toluidina revelou menor sensibilidade, especificidade, valor preditivo positivo e valor preditivo negativo. CONCLUSÃO: Os testes imunoquímicos revelaram maior sensibilidade, especificidade e valores de predição na detecção de sangramento colorretal. Os testes imunoquímicos apresentaram melhores índices de concordância com a colonoscopia, quando comparados ao teste da o-toluidina.


Assuntos
Humanos , Masculino , Feminino , Adolescente , Adulto , Adulto Jovem , Toluidinas/análise , Neoplasias Colorretais/diagnóstico , Colonoscopia/normas , Fezes/química , Sangue Oculto , Imuno-Histoquímica , Programas de Rastreamento , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Detecção Precoce de Câncer , Pessoa de Meia-Idade