Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Restor Dent Endod ; 47(3): e29, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36090515

RESUMO

Objectives: This study aimed to investigate the anti-erosive/abrasive effect of resin infiltration of previous deproteinized dentin. Materials and Methods: Dentin slabs were randomly assigned to 3 groups (n = 15): Control (no deproteinization; no resin infiltrant applied), RI (no deproteinization; resin infiltrant applied), and DRI (deproteinization; resin infiltrant applied). After undergoing the assigned treatment, all slabs were subjected to an in vitro cycling model for 5 days. The specimens were immersed in citric acid (0.05 M, pH = 3.75; 60 seconds; 3 times/day) and brushed (150 strokes). Between the challenges, the specimens were exposed to a remineralizing solution (60 minutes). The morphological alterations were analyzed by mechanical profilometry (µm) and scanning electron microscopy (SEM). Data were submitted to one-way analysis of variance (ANOVA) and Tukey tests (p < 0.05). Results: Control and RI groups presented mineral wear and did not significantly differ from each other (p = 0.063). DRI maintained a protective layer preserving the dentin (p < 0.001). After erosive/abrasive cycles, it was observed that in group RI, only 25% of the slabs partially evidenced the presence of the infiltrating, while, in the DRI group, 80% of the slabs presented the treated surface entirely covered by a resin-component layer protecting the dentin surface as observed in SEM images. Conclusions: The removal of the organic content allows the resin infiltrant to efficiently protect the dentin surface against erosive/abrasive lesions.

2.
Photodiagnosis Photodyn Ther ; 33: 102046, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33031937

RESUMO

BACKGROUND: There are investigations on multiple photosensitizers for modulation of caries-related biofilms using PDT. However, much controversy remains about recommended parameters mostly on the selection of an efficient photosensitizer. OBJECTIVE: The study performed a systematic review to identify the answer to the following question: What photosensitizers present high bactericidal efficacy against cariogenic biofilms? METHODS: Systematic review with meta-analyses were carried out for English language articles from October to December 2019 (PRISMA standards) using MEDLINE, Scopus, Biomed Central, EMBASE, LILACS, and Web of Science. Information on study design, biofilm model, photosensitizer, light source, energy delivery, the incubation time for photosensitizer, and bacterial reduction outcomes were recorded. We performed two meta-analyses to compare bacterial reduction, data was expressed by (1) base 10 Logarithm values and (2) Log reduction RESULTS: After the eligibility criteria were applied (PEDro scale), the selected studies showed that toluidine Blue Ortho (TBO) and methylene blue (MBO) (5-min incubation time and 5-min irradiation) demonstrated better bacterial reduction outcomes. For the data expressed by Log TBO, MBO, curcumin, and Photogem® presented a significant bacterial decrease in comparison to the control (p = 0.042). For the data represented by Log reduction, the bacterial reduction toward S.mutans was not significant for any photosensitizer (p = 0.679). CONCLUSION: The lack of methodological standardization among the studies still hinders the establishment of photosensitizer and bactericidal efficiency. TBO, MBO, curcumin, and photogem generate greater PDT-based bacterial reduction on caries-related bacteria.. Further clinical studies are necessary in order to obtain conclusive results.


Assuntos
Fotoquimioterapia , Fármacos Fotossensibilizantes , Biofilmes , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes/farmacologia , Streptococcus mutans , Cloreto de Tolônio/farmacologia , Triazenos
3.
Photomed Laser Surg ; 32(7): 379-85, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24992272

RESUMO

OBJECTIVE: This study investigated the effect of phosphoric acid concentration on microshear bond strength (µSBS) of an etch-and-rinse adhesive system to demineralized irradiated enamel. BACKGROUND DATA: Er:YAG laser irradiation may increase acid resistance of enamel; however, its use is associated with reduced bonding effectiveness. MATERIALS AND METHODS: Three experimental etching agents and one bonding agent were fabricated. Enamel pretreatment was tested in two levels (bur and laser) and phosphoric acid was tested in four levels (control and at 35, 45, or 55%). Commercially available phosphoric acid and a bonding agent were used as control. Enamel samples were submitted to a pH-cycling model to induce demineralization. Half of the exposed demineralized enamel area was prepared with diamond bur and half was prepared with an Er:YAG laser (λ=2.94 µm, 300 mJ, 2 Hz). Specimens were randomly allocated to receive different acid etching concentrations and either the experimental or the commercial adhesive system. Microshear bond strength and the adhesive remnant index (ARI) scores were determined. µSBS's data were evaluated by two way analysis of variance (ANOVA) and Tukey's test. Kruskal-Wallis followed by Dunn's method and Mann-Whitney test were used for ARI comparisons (α=5%). RESULTS: For µSBS, no significant difference among the groups was found, either for phosphoric acid concentration or surface preparation. For ARI scores, statistically higher resin retention was found for lased groups (p<0.001). CONCLUSIONS: The increase of phosphoric acid concentration did not impair bond strength regardless of surface preparation; however, increased retention was found when demineralized enamel was prepared with laser.


Assuntos
Colagem Dentária , Esmalte Dentário , Lasers de Estado Sólido , Ácidos Fosfóricos/administração & dosagem , Condicionamento Ácido do Dente/métodos , Adesivos , Adesivos Dentinários , Géis , Humanos , Técnicas In Vitro
4.
Photomed Laser Surg ; 32(3): 146-51, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24552442

RESUMO

OBJECTIVE: This in vitro study aimed to evaluate the effect of a low intensity diode laser (λ=808 nm; 60 J/cm2) associated with stannous fluoride on the inhibition of dentin erosion by assessing percentage of superficial hardness loss (%SHL) and calcium release into the acid solution. MATERIALS AND METHODS: Human root dentin slabs were assigned to eight groups (n=10), according to treatments (control, stannous fluoride, diode laser therapy, and the combination of stannous fluoride and laser therapy), and acid challenge (hydrochloridric or citric acid). All slabs were subjected to a previous 2 h acquired pellicle formation; laser and fluoride treatments were performed according to the groups. Subsequently, the slabs were exposed to erosive challenge (0.01 M hydrochloridric acid or citric acid 1% for 60 sec). Additionally, calcium released into the acid solution during erosive challenge was analyzed by photometric test. Data were analyzed by ANOVA followed by Tukey's test (p<0.05). RESULTS: Mean values (±SD) for %SHL of treated groups did not present statistically significant differences, regardless of the erosive challenge. However, in relation to released calcium concentration, groups treated with laser presented statistically significant lower calcium loss under hydrochloridric acid challenge (p<0.001). To groups under citric acid attack, only the combination of treatments (p=0.037) was able to show a protective effect on dentin. CONCLUSIONS: Under the conditions of this study, 808 nm diode laser with or without stannous fluoride could effectively reduce dentin surface loss under both acid exposures. Only calcium concentration analysis was sensitive enough to measure the effects under the tested conditions.


Assuntos
Dentina , Terapia com Luz de Baixa Intensidade , Fluoretos de Estanho/farmacologia , Erosão do Colo do Útero/prevenção & controle , Dentina/efeitos dos fármacos , Feminino , Humanos , Técnicas In Vitro
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA