Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Arq Bras Cardiol ; 102(3 Suppl 1): 1-61, 2014 03.
Artigo em Português | MEDLINE | ID: mdl-24862929
2.
J Nucl Cardiol ; 8(6): 652-9, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11725261

RESUMO

BACKGROUND: Myocardial perfusion imaging with dipyridamole is an alternative with which to evaluate patients who are unable to exercise. Many patients who undergo dipyridamole testing are limited in their ability, but are not completely unable, to exercise. There are benefits from adding low workload exercise to dipyridamole testing, including a reduction of thallium 201 concentration in the liver, leading to a higher heart-to-liver activity ratio and better image quality. This prospective study was designed to evaluate a protocol of exercise supplementation during dipyridamole technetium 99m sestamibi imaging and to verify whether a higher heart-to-liver activity ratio could be obtained. We also evaluated the potential of this combined protocol to prevent hypotension and induce ischemic changes on the electrocardiogram (ECG). METHODS AND RESULTS: Ninety consecutive patients who were not completely disabled for exercise underwent dipyridamole Tc-99m sestamibi cardiac single photon emission computed tomography with a protocol of exercise supplementation (DipEx). The heart-to-liver activity ratio, hemodynamics, and electrocardiographic changes were studied. The findings were compared with those of a control group (Dip) composed of 99 patients who underwent dipyridamole infusion alone. Patients with left bundle branch block, pacemaker, and atrial fibrillation were excluded. The DipEx patients tolerated the protocol, exercising 4.2 +/- 1.3 minutes on the treadmill (Bruce protocol). Compared with Dip, patients in the DipEx group had a higher heart-to-liver activity ratio (1.3 +/- 0.4 vs 1.6 +/- 0.5, respectively; P =.00001), had no incidence of hypotension (6% vs 0%, respectively; P =.03), and had a higher sensitivity of the ECG to detect ischemia (6% vs 34%, respectively; P =.003). The increase in sensitivity seen in the DipEx group was accompanied by a significant decrease in specificity compared with the Dip group (67% vs 100%, P =.000001). CONCLUSIONS: Our data show that the addition of limited exercise to dipyridamole results in benefits during Tc-99m sestamibi imaging, increasing heart-to-liver activity ratio, preventing vasodilator-induced hypotension, and improving ECG sensitivity for the detection of ischemia. Furthermore, this protocol also provides an estimation of the patient's physical capacity and could be used as an alternative for patients undergoing dipyridamole infusion who are not completely unable to exercise.


Assuntos
Dipiridamol/uso terapêutico , Eletrocardiografia/efeitos dos fármacos , Teste de Esforço/efeitos dos fármacos , Teste de Esforço/métodos , Coração/diagnóstico por imagem , Coração/fisiopatologia , Hipotensão/prevenção & controle , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/fisiopatologia , Compostos Radiofarmacêuticos , Tecnécio Tc 99m Sestamibi , Vasodilatadores/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Hemodinâmica/efeitos dos fármacos , Hemodinâmica/fisiologia , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único , Avaliação da Capacidade de Trabalho
3.
Free Radic Biol Med ; 31(4): 440-9, 2001 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-11498277

RESUMO

Free radicals superoxide (O(2)(-)) and nitric oxide (*NO) are generated by blood vessels and can rapidly react to produce a peroxynitrite anion (ONOO(-)), a powerful oxidant that modifies lipoproteins making them more atherogenic. The aim of this study was to investigate the effect of peroxynitrite-induced modifications on beta-very-low-density lipoprotein (beta-VLDL) as to its biodistribution and plasma clearance rate, as well as the uptake of these particles by THP-1 cells. After being injected into New Zealand White rabbits, the peroxynitrite-modified beta-VLDL (99mTc-per-beta-VLDL) was cleared from circulation faster than the native beta-VLDL (99mTc-nat-beta-VLDL) in both normocholesterolemic rabbits (NC) and in hypercholesterolemic rabbits (HC). In HC rabbits, the fractional clearance of 99mTc-labeled beta-VLDL was significantly lower than in NC rabbits. The in vivo studies showed that accumulation of 99mTc-labeled beta-VLDL, expressed per gram of tissue, followed the decreasing order: kidney > liver > spleen > adrenal gland >or= lung > aortic arch > heart >or= abdominal aorta > thoracic aorta > psoas muscle. The high accumulation in the kidneys suggests the processing of 99mTc-labeled apolipoproteins by receptors present in kidney cells. The accumulation of 99mTc-nat-beta-VLDL in the whole organ was the following: liver > kidney > heart > spleen > adrenal gland > aorta in HC and NC rabbits. The uptake of 99mTc-per-beta-VLDL by the spleen was greater than the uptake by the heart in both groups. The in vitro studies showed that the uptake of 99mTc-per-beta-VLDL by THP-1 cells was higher than that of 99mTc-nat-beta-VLDL. These results show that peroxynitrite-modified beta-VLDL is rapidly removed from plasma and accumulates in several tissues, mainly in the liver and kidney. This may be particularly important in hypercholesterolemic situations that could favor the accumulation of native and peroxynitrite-modified beta-VLDL in several tissues.


Assuntos
Lipoproteínas VLDL/farmacocinética , Animais , Masculino , Taxa de Depuração Metabólica , Ácido Peroxinitroso , Coelhos , Tecnécio/farmacocinética , Distribuição Tecidual
4.
Arq Bras Cardiol ; 72(5): 523-45, 1999 May.
Artigo em Inglês, Português | MEDLINE | ID: mdl-10668224

RESUMO

OBJECTIVE: To compare single-photon-emission computed tomography (SPECT) imaging scans using 201Tl and 99mTc-MIBI in detection of viable myocardium, in regions compromised by infarction. METHODS: Thirty-two (59.3 +/- 9.8 years old and 87% male) myocardial infarction patients were studied. All had Q waves on the ECG and left ventricle ejection fraction of < 50%. They underwent coronary and left ventricle angiographies and SPECT before (including 201Tl reinjection) and after coronary artery bypass surgery (CABG). Improvement in perfusion observed after surgery was considered the gold standard for myocardial viability. RESULTS: Among 102 studied regions of the heart, there were 40 (39.2%) areas of transient perfusion defects in the conventional protocol with 201Tl and 52 (51.0%) after reinjection. Therefore, 12/62 (19.4%) more viable regions were identified by reinjection. Using 99mTc-MIBI, only 14 (13.7%) regions with transient defects were identified, all of which were seen also in 201Tl protocols. After surgery, 49 of a total of 93 regions analyzed (52.7%) were viable. Sensitivity, specificity, accuracy, positive and negative prediction values were, respectively, 201Tl SPECT scans--65.3%, 90.9%, 77.4%, 88.9% and 70.2%, reinjection protocol with 201Tl scans--81.5%, 81.8%, 81.7%, 83.3% and 80.0%, 99mTc-MIBI SPECT scans--20.4%, 90.9%, 53.8%, 71.4% and 50.6%. Logistic regression demonstrated that the reinjection protocol with 201Tl was the best predictor of viability (P < 0.001). CONCLUSION: Our data suggest the election of 201Tl for viability studies, especially when using the reinjection protocol.


Assuntos
Coração/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Revascularização Miocárdica , Sobrevivência de Tecidos , Adulto , Idoso , Feminino , Coração/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/cirurgia , Período Pós-Operatório , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Radioisótopos de Tálio/administração & dosagem , Tomografia Computadorizada de Emissão de Fóton Único
5.
Braz J Med Biol Res ; 30(6): 705-17, 1997 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9292106

RESUMO

The biodistribution and removal from plasma (measured as fractional clearance rate, FCR, per hour) of native and oxidatively modified 99mtechnetium-labeled beta-very low density lipoprotein (99mTc-beta-VLDL) were investigated in hypercholesterolemic (HC) and control (C) three-month old New Zealand rabbits. The intracellular accumulation of beta-VLDL labeled with 99mTc was studied in vitro in THP-1 cells and monocyte-derived macrophages isolated from rabbits. After intravenous injection into C rabbits, copper-oxidized beta-VLDL (99mTc-ox-beta-VLDL) was cleared from the circulation faster (0.362 +/- 0.070/h) than native beta-VLDL (99mTc-nat-beta-VLDL, 0.241 +/- 0.070/h). In contrast, the FCR of 99mTc-ox-beta-VLDL in HC rabbits was lower (0.100 +/- 0.048/h) than that of 99mTc-nat-beta-VLDL (0.163 +/- 0.043/h). The hepatic uptake of radiolabeled lipoproteins was lower in HC rabbits (0.114 +/- 0.071% injected dose/g tissue for 99mTc-nat-beta-VLDL and 0.116 +/- 0.057% injected dose/g tissue for 99mTc-ox-beta-VLDL) than in C rabbits (0.301 +/- 0.113% injected dose/g tissue for 99mTc-nat-beta-VLDL and 0.305 +/- 0.149% injected dose/g tissue for 99mTc-ox-beta-VLDL). The uptake of 99mTc-nat-beta-VLDL and 99mTc-ox-beta-VLDL by atherosclerotic aorta lesions isolated from HC rabbits (99mTc-nat-beta-VLDL: 0.033 +/- 0.012% injected dose/g tissue and 99mTc-ox-beta-VLDL: 0.039 +/- 0.017% injected dose/g tissue) was higher in comparison to that of non-atherosclerotic aortas from C rabbits (99mTc-nat-beta-VLDL: 0.023 +/- 0.010% injected dose/g tissue and 99mTc-ox-beta-VLDL: 0.019 +/- 0.010% injected dose/g tissue). However, 99mTc-nat-beta-VLDL and 99mTc-ox-beta-VLDL were taken up by atherosclerotic lesions at similar rates. In vitro studies showed that both monocyte-derived macrophages isolated from rabbits and THP-1 macrophages significantly internalized more 99mTc-ox-beta-VLDL than 99mTc-nat-beta-VLDL. These results indicate that in cholesterol-fed rabbits 99mTc-ox-beta-VLDL is slowly cleared from plasma and accumulates in atherosclerotic lesions. However, although the extent of in vitro uptake of 99mTc-ox-beta-VLDL by macrophages was high, the in vivo accumulation of this radiolabeled lipoprotein by atherosclerotic lesions did not differ from that of 99mTc-nat-beta-VLDL.


Assuntos
Lipoproteínas VLDL/farmacocinética , Pertecnetato Tc 99m de Sódio/farmacocinética , Animais , Arteriosclerose/metabolismo , Lipídeos/sangue , Lipoproteínas VLDL/sangue , Lipoproteínas VLDL/isolamento & purificação , Ativação de Macrófagos/fisiologia , Masculino , Taxa de Depuração Metabólica , Coelhos , Pertecnetato Tc 99m de Sódio/sangue , Pertecnetato Tc 99m de Sódio/isolamento & purificação , Distribuição Tecidual/fisiologia
6.
Braz. j. med. biol. res ; 30(6): 705-17, jun. 1997. ilus, tab, graf
Artigo em Inglês | LILACS | ID: lil-194169

RESUMO

The biodistribution and removal from plasma (measured as fractional clerance rate, FCR, per hour) of native and oxidatively modified (99m)technetium-labeled Beta-very low density lipoprotein ((99m)Tc-Beta-VLDL)) were investigated in hypercholesterolemic (HC) and control (C) three-month old New Zealand rabbits. The intracellular accumulation of Beta-VLDL labeled with (99m)Tc was studied in vitro in THP-1 cells and monocyte-derived macrophages isolated from rabbits. After intravenous injection into C rabbits, copper-oxidized Beta-VLDL ((99m)Tc-ox-Beta-VLDL)) was cleared from the circulation faster (0.362 + 0.070/h) than native Beta-VLDL ((99m)Tc-nat-Beta-VLDL, 0.241 + 0.070/h)). In contrast, the FCR of (99m)Tc-ox-Beta-VLDL in HC rabbits was lower (0.100 + 0.048/h) than that of (99m)Tc-nat-Beta-VLDL (0.163 + 0.043/h). The hepatic uptake of radiolabeled lipoproteins was lower in HC rabbits (0.114 + 0.071 percent injected dose/g tissue for (99m)Tc-nat-Beta-VLDL and 0.116 + 0.057 percent injected dose/g tissue for (99m) Tc-ox-Beta-VLDL) than in C rabbits (0.301 + 0.113 percent injected dose/g tissue for (99m)Tc-nat-Beta-VLDL and 0.305 + 0.149 percent injected dose/g tissue for ((99m)Tc-ox-Beta-VLDL). The uptake of (99m)Tc-nat-Beta-VLDL and (99m)Tc-ox-Beta-VLDL by atherosclerotic aorta lesions isolated from HC rabbits ((99m)Tc-nat-Beta-VLDL:0.033 + 0.012 percent injected dose/g tissue and (99m)Tc-ox-Beta-VLDL: 0.039 + 0.017 percent injected dose/g tissue) was higher in comparison to that of non-atherosclerotic aortas from C rabbits (99m)Tc-nat-Beta-VLDL: 0.023 + 0.010 percent injected dose/g tissue and (99m)Tc-ox-Beta VLDL: 0.019 + 0.010 percent injected dose/g tissue). However, (99m) Tc-nat-Beta-VLDL and (99m)Tc-ox-Beta-VLDL were taken up by atherosclerotic lesions at similar rates. In vitro studies showed that both monocyte-derived macrophages isolated from rabbits and THP-1 macrophages significantly internalized more (99m)Tc-ox-Beta-VLDL than (99m)Tc-nat-Beta-VLDL. These results indicate that in cholesterol-fed rabbits (99m)Tc-ox-Beta-VLDL is slowly cleared from plasma and accumulates in atherosclerotic lesions. However, although the extent of in vitro uptake of (99m)Tc-ox-Beta-VLDL by macrophages was high, the in vivo accumulation of this radiolabeled lipoprotein by atherosclerotic lesions did not differ from that of (99m)Tc-nat-Beta-VLDL.


Assuntos
Coelhos , Animais , Masculino , Aterosclerose/metabolismo , Lipídeos/sangue , Lipoproteínas VLDL/sangue , Lipoproteínas VLDL/isolamento & purificação , Lipoproteínas VLDL/farmacologia , Ativação de Macrófagos/fisiologia , Pertecnetato Tc 99m de Sódio/sangue , Pertecnetato Tc 99m de Sódio/isolamento & purificação , Pertecnetato Tc 99m de Sódio/farmacocinética , Distribuição Tecidual/fisiologia , Autorradiografia , Taxa de Depuração Metabólica
7.
Arq Bras Cardiol ; 68(3): 163-6, 1997 Mar.
Artigo em Português | MEDLINE | ID: mdl-9435353

RESUMO

PURPOSE: To evaluate the sensitivity and specificity of myocardial perfusion scintigraphy in the detection of coronary artery disease in patients with right bundle branch block (RBBB). METHODS: Thirty one patients (24 male, 62.3 +/- 10.5 years) with RBBB, submitted to myocardial perfusion scintigraphy associated with exercise (n = 7) or dipyridamole (n = 24) and previous cinecoronariography were studied retrospectively. Left ventricle scintigraphic image was divided in three segments corresponding to the three main epicardic coronary territories in a total of 93 segments. Cineangiographic and scintigraphic data were then compared according to the different artery territories. RESULTS: Twenty three patients had significant lesions (> or = 60%) in one or more coronary arteries and eight had no obstruction. Forty nine segments were irrigated by normal coronary arteries and 44 were related to arteries that had significant lesions. Twenty out of twenty three patients showed alterations in perfusion (sensitivity = 87%). All patients without coronary obstructions showed normal perfusion scintigraphy (specificity = 100%). One of the segments perfused by normal coronaries showed abnormal scintigraphy. Scintigraphy showed perfusion defects in 29 out of 44 segments with coronary obstructions. Sensitivity and specificity of the method for each arterial territory were 72% and 100% (left descending coronary artery), 67% and 94% (right coronary artery), 55% and 100% (circunflex coronary artery), respectively. CONCLUSION: The presence of RBBB does not modify the sensitivity and specificity of the method in the detection of coronary artery disease.


Assuntos
Bloqueio de Ramo/complicações , Doença das Coronárias/diagnóstico por imagem , Bloqueio de Ramo/diagnóstico por imagem , Angiografia Coronária , Doença das Coronárias/etiologia , Teste de Esforço , Feminino , Humanos , Masculino , Análise por Pareamento , Cintilografia , Estudos Retrospectivos , Sensibilidade e Especificidade
8.
Braz J Med Biol Res ; 29(11): 1467-71, 1996 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-9196547

RESUMO

The aim of this study was to compare gallium-67 citrate lung imaging with the pulmonary clearance of 99mTc-DTPA (technetium 99m diethylenetriaminepentaacetic acid) in 9 patients with amiodarone pneumonitis (8 males and 1 female, aged 58 to 76 years). The diagnosis of amiodarone pneumonitis was based on clinical and radiological grounds in all patients, and histological changes in seven. The mean values for the effective half-life of the pulmonary clearance of 99mTc-DTPA aerosol were below the normal range in all 9 patients, and lower than the values obtained previously for patients on a long-term amiodarone regimen without side effects. Positive gallium-67 accumulation was demonstrated in 7 of the 9 patients. Two patients had negative gallium-67 imaging and increased alveolar-capillary 99mTc-DTPA clearance; with corticosteroid therapy and discontinuation of amiodarone, their radiological changes and clearance became normal within 120 days. In conclusion, when compared to gallium-67 lung imaging, the 99mTc-DTPA aerosol clearance is more advantageous because it is a much faster test than the gallium scan. This is essential for those patients suspected of amiodarone pneumonitis who need specific therapy as soon as possible. Moreover, the 99mTc-DTPA aerosol clearance test appears to be a more useful diagnostic tool because it is positive even in those patients who have normal gallium-67 lung imaging.


Assuntos
Amiodarona/efeitos adversos , Radioisótopos de Gálio , Pneumonia/induzido quimicamente , Pneumonia/diagnóstico , Pentetato de Tecnécio Tc 99m , Adulto , Aerossóis , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Taxa de Depuração Metabólica , Pessoa de Meia-Idade , Pneumonia/metabolismo , Pentetato de Tecnécio Tc 99m/farmacocinética
9.
Braz. j. med. biol. res ; 29(11): 1467-71, Nov. 1996. tab
Artigo em Inglês | LILACS | ID: lil-187207

RESUMO

The aim of this study was to compare gallium-67 citrate lung imaging with the pulmonary clearance of 99mTc-DTPA (technetium 99m diethylenetriaminepentaacetic acid) in 9 patients with amiodarone pneumonitis (8 males and 1 female, aged 58 to 76 years). The diagnosis of amiodarone pneumonitis was based on clinical and radiological grounds in all patients, and histological changes in seven. The mean values for the effective half-life of the pulmonary clearance of 99mTc-DTPA aerosol were below the normal range in all 9 patients, and lower than the values obtained previously for patients on a long-term amiodarone regimen without side effects. Positive gallium-67 accumulation was demonstrated in 7 of the 9 patients. Two patients had negative gallium-67 imaging and increased alveolar-capillary 99mTc-DTPA clearance; with corticosteroid therapy and discontinuation of amiodarone, their radiological changes and clearance became normal within 120 days. In conclusion, when compared to gallium-67 lung imaging, the 99mTc-DTPA aerosol clearance is more advantageous because it is a much faster test than the gallium scan. This is essential for those patients suspected of amiodarone pneumonitis who need specific therapy as soon as possible. Moreover, the 99mTc-DTPA aerosol clearance test appears to be a more useful diagnostic tool because it is positive even in those patients who have normal gallium-67 lung imaging.


Assuntos
Adulto , Humanos , Feminino , Pessoa de Meia-Idade , Amiodarona/efeitos adversos , Radioisótopos de Gálio , Pneumonia/diagnóstico , Pentetato de Tecnécio Tc 99m , Corticosteroides/uso terapêutico , Idoso de 80 Anos ou mais
10.
Braz J Med Biol Res ; 29(5): 605-13, 1996 May.
Artigo em Inglês | MEDLINE | ID: mdl-9033810

RESUMO

To determine whether or not slow coronary flow (SF) depends on hemodynamic variables, we studied 17 patients (15 men, mean age = 47.8 years) with SF at coronariography. Exercise thallium-201 myocardial scintigraphy revealed perfusion abnormalities in 13 (76.4%) patients. We then selected 89 individuals submitted to cinecoronariography for comparison: 15 were normal and 74 had heart disease. The coronary flow velocity was evaluated by the number of heart beats (HB) needed for coronary artery dye filling. The patients in the SF group had normal hemodynamic variables which were significantly different from those of patients with heart disease (P = 0.001). Patients with heart disease needed no more than 4 HB to fill their arteries, in contrast to 6.88 +/- 1.68 (5 to 11) in the SF group (P < 0.0001). Thus, in our patients with myocardial scintigraphy suggesting ischemia, SF was found to be an event which did not depend on hemodynamic factors.


Assuntos
Angina Pectoris/diagnóstico por imagem , Circulação Coronária/fisiologia , Doença das Coronárias/diagnóstico por imagem , Radioisótopos de Tálio , Adulto , Idoso , Análise de Variância , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Hemodinâmica/fisiologia , Humanos , Masculino , Pessoa de Meia-Idade , Cintilografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA