Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
Braz. oral res ; 27(2): 169-175, Mar-Apr/2013. tab, graf
Artigo em Inglês | LILACS | ID: lil-668004

RESUMO

The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric acid / 60s and silanized. The dentin was treated with 37% phosphoric acid / 15s, and the adhesive was applied. The ceramic blocks were divided and cemented to dentin according to resin cement / RC curing type (dual- and photo-cured), light-curing unit (halogen light / QTH and LED), and storage conditions (dry and storage / 150 days + 12,000 cycles / thermocycling). All blocks were stored in distilled water (37°C / 24h) and sectioned (n = 10): G1 - QTH + RC Photo, G2 - QTH + RC Dual, G3 - LED + RC Photo, G4 - LED + RC Dual. Groups G5, G6, G7, and G8 were obtained exactly as G1 through G4, respectively, and then stored and thermocycled. Microtensile bond strength tests were performed (EMIC), and data were statistically analyzed by ANOVA and Tukey's test (5%). The bond strength values (MPa) were: G1 - 12.95 (6.40)ab; G2 - 12.02 (4.59)ab; G3 - 13.09 (5.62)ab; G4 - 15.96 (6.32)a; G5 - 6.22 (5.90)c; G6 - 9.48 (5.99)bc; G7 - 12.78 (11.30)ab; and G8 - 8.34 (5.98)bc. The same superscript letters indicate no significant differences. Different light-curing units affected the bond strength between ceramic cemented to dentin when the photo-cured cement was used, and only after aging (LED > QTH). There was no difference between the effects of dual- and photo-cured resin-luting agents on the microtensile bond strength of the cement used in this study.


Assuntos
Humanos , Lâmpadas de Polimerização Dentária , Cerâmica/química , Colagem Dentária/métodos , Dessensibilizantes Dentinários/química , Dentina/efeitos dos fármacos , Cimentos de Resina/química , Análise de Variância , Cerâmica/efeitos da radiação , Falha de Restauração Dentária , Dessensibilizantes Dentinários/efeitos da radiação , Dentina/química , Teste de Materiais , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Água/química
2.
Braz Oral Res ; 27(2): 169-75, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23459773

RESUMO

The aim of this study was to evaluate the effects of different light-curing units and resin cement curing types on the bond durability of a feldspathic ceramic bonded to dentin. The crowns of 40 human molars were sectioned, exposing the dentin. Forty ceramic blocks of VITA VM7 were produced according to the manufacturer's recommendations. The ceramic surface was etched with 10% hydrofluoric acid / 60s and silanized. The dentin was treated with 37% phosphoric acid / 15s, and the adhesive was applied. The ceramic blocks were divided and cemented to dentin according to resin cement / RC curing type (dual- and photo-cured), light-curing unit (halogen light / QTH and LED), and storage conditions (dry and storage / 150 days + 12,000 cycles / thermocycling). All blocks were stored in distilled water (37°C / 24h) and sectioned (n = 10): G1 - QTH + RC Photo, G2 - QTH + RC Dual, G3 - LED + RC Photo, G4 - LED + RC Dual. Groups G5, G6, G7, and G8 were obtained exactly as G1 through G4, respectively, and then stored and thermocycled. Microtensile bond strength tests were performed (EMIC), and data were statistically analyzed by ANOVA and Tukey's test (5%). The bond strength values (MPa) were: G1 - 12.95 (6.40)ab; G2 - 12.02 (4.59)ab; G3 - 13.09 (5.62)ab; G4 - 15.96 (6.32)a; G5 - 6.22 (5.90)c; G6 - 9.48 (5.99)bc; G7 - 12.78 (11.30)ab; and G8 - 8.34 (5.98)bc. The same superscript letters indicate no significant differences. Different light-curing units affected the bond strength between ceramic cemented to dentin when the photo-cured cement was used, and only after aging (LED > QTH). There was no difference between the effects of dual- and photo-cured resin-luting agents on the microtensile bond strength of the cement used in this study.


Assuntos
Cerâmica/química , Lâmpadas de Polimerização Dentária , Colagem Dentária/métodos , Dessensibilizantes Dentinários/química , Dentina/efeitos dos fármacos , Cimentos de Resina/química , Análise de Variância , Cerâmica/efeitos da radiação , Falha de Restauração Dentária , Dentina/química , Dessensibilizantes Dentinários/efeitos da radiação , Humanos , Teste de Materiais , Propriedades de Superfície , Resistência à Tração , Fatores de Tempo , Água/química
3.
J Prosthodont ; 21(2): 94-100, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22050205

RESUMO

PURPOSE: The aim of this study was to evaluate the marginal discrepancy (MD) and internal discrepancy (ID) of ceramic crowns manufactured by a CAD/CAM system, having different finish lines. The hypotheses tested were that the finish line type would not influence the MD or ID of the crowns, and ID would not change in different regions. MATERIALS AND METHODS: Three aluminum master dies (height: 5.5 mm, Ø: 7.5 mm, conicity: 6°) with different finish lines (TC: tilted chamfer; LC: large chamfer; RS: rounded shoulder) were manufactured. Ten impressions were made from each master die using a modified parallelometer. Impressions were poured in type IV dental stone, and 30 ceramic crowns (IPS Empress CAD, Ivoclar) were subsequently milled. The crowns were fixed on their respective metallic die using a metallic fixation device. The distance between the external edges of the crown to the edge of the cervical preparation was performed at 50 points on the respective metallic die (MD analysis). With the replica technique, the ID values of each crown were further evaluated at 12 points equidistant to each other in three regions: radius (R), axial (A), and occlusal (Occl). The measurements were performed using an optical microscope (250×). The data (µm) were analyzed using ANOVA and Tukey's test (5%). RESULTS: The RS group (28.24 ± 11.42 µm) showed significantly lower MD values (p= 0.001) than those of TC (99.92 ± 18.32 µm) and LC (64.71 ± 25.64 µm) groups, both of which also differed statistically from one another. The ID results demonstrated significantly lower values in the LC group (183.01 ± 62.82 µm) (p= 0.0014) than those of TC (216.26 ± 83.23 µm) and RS (219.12 ± 87.24 µm) groups. ID results of TC and RS were not significantly different. Additionally, the ID results showed significant differences among the regions (p= 0.0001). The null hypotheses were rejected. CONCLUSION: The RS finish line produced MD values significantly lower than tilted and large chamfer, but large chamfer presented the lowest internal discrepancy values. Independent of the finish line type, internal discrepancy was the lowest in the axial region followed by radius and occlusal regions.


Assuntos
Desenho Assistido por Computador , Coroas , Adaptação Marginal Dentária , Porcelana Dentária , Planejamento de Prótese Dentária , Análise de Variância , Técnica de Moldagem Odontológica , Humanos , Modelos Dentários , Ajuste de Prótese , Técnicas de Réplica , Estatísticas não Paramétricas , Preparo Prostodôntico do Dente
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA