Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Matern Fetal Neonatal Med ; 24(11): 1384-91, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21401311

RESUMO

OBJECTIVES: The aim of this study was to evaluate feasibility of fetal lateral ventricle (LV) volumetry in fetuses with ventriculomegaly and to compare measurements performed by 3D sonographic method virtual organ computer-aided analysis (VOCAL) with those obtained by magnetic resonance imaging (MRI). METHODS: This cross-sectional study evaluated 30 fetuses with atrial width (AW) between 10 and 30 mm, from 20 to 36 gestational weeks. Fifty-nine ventricles were measured by two observers. Sonographic volumetric measurements using VOCAL 30° were performed with an ACCUVIX XQ machine (Medison, Korea) and MRI assessments with a Sonata system using ARGUS software (Siemens, Germany). Agreement between both techniques was assessed by intraclass correlation coefficient (ICC) calculation, and proportionate Bland-Altman plots were constructed. RESULTS: A high degree of reliability was observed between VOCAL and MRI measurements (ICC 0.928, 95%CI [0.876;0.958]). Bland-Altman plots confirmed the high correlation (mean of differences: 1.62 cm(3) and standard deviation: ± 8.41 cm(3)). CONCLUSION: Three-dimensional volumetry of fetal LVs by VOCAL method has good agreement with fetal MRI in fetuses with ventriculomegaly and may be used as an additional tool in patient counseling and prognosis prediction.


Assuntos
Ventrículos Cerebrais/embriologia , Hidrocefalia/embriologia , Imageamento por Ressonância Magnética , Ultrassonografia Pré-Natal , Adolescente , Adulto , Ventrículos Cerebrais/diagnóstico por imagem , Estudos Transversais , Feminino , Humanos , Hidrocefalia/diagnóstico por imagem , Hidrocefalia/patologia , Masculino , Gravidez , Prognóstico , Ultrassonografia Pré-Natal/métodos
2.
Cardiovasc Ultrasound ; 8: 17, 2010 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-20459848

RESUMO

BACKGROUND: To assess the reliability of fetal heart volume measurement by three-dimensional sonography (3DUS) using the eXtended Imaging Virtual Organ Computer-aided AnaLysis (XI VOCAL) method. METHODS: This reliability study enrolled 30 pregnant women with singleton healthy pregnancies between 19 and 34 weeks of gestation. All volume acquirements were performed with a convex volumetric transducer (C3-7ED) coupled to an Accuvix XQ sonography device (Medison, Korea). The XI VOCAL 10 planes was the method of choice for volumetric measurement. 3D datasets were analyzed by two observers (EQSB and HJFM); fetal heart volume was measured twice by the first and once by the second observer to calculate intra and interobserver reproducibility. Statistical analysis used pareated Student's t test (p) and calculated Intraclass correlation coefficients (ICC). Bland-Altman plots were also constructed. RESULTS: We observed an excellent intra- and interobserver reliability for fetal cardiac volume assessed by XI VOCAL. For the intraobserver the ICC was 0.998 (95% CI: 0.997; 0.999), with mean of differences of 0.12 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.130). For interobserver the ICC was 0.899 (95%CI: 0.996; 0.998), mean of differences 0.05 cm3 (95% limits of agreement: -0.84; +0.84; p = 0.175). CONCLUSION: Fetal cardiac volume assessed by 3DUS using XI VOCAL method is highly reproducible between 19 to 34 gestational weeks.


Assuntos
Volume Cardíaco , Coração Fetal/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Imageamento Tridimensional , Ultrassonografia Pré-Natal , Adolescente , Adulto , Feminino , Humanos , Variações Dependentes do Observador , Gravidez , Reprodutibilidade dos Testes , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA