Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Diagnostics (Basel) ; 13(8)2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-37189527

RESUMO

Pneumatosis cystoid intestinalis (PCI) is a rare condition, with a worldwide incidence of 0.3-1.2%. PCI is classified into primary (idiopathic) and secondary forms, with 15% and 85% of presentations, respectively. This pathology was associated with a wide variety of underlining etiologies to explain the abnormal accumulation of gas within the submucosa (69.9%), subserosa (25.5%), or both layers (4.6%). Many patients endure misdiagnosis, mistreatment, or even inadequate surgical exploration. In this case, a patient presented acute diverticulitis, after treatment, a control colonoscopy was performed that found multiple rounds and elevated lesions. To further study the subepithelial lesion (SEL), a colorectal endoscopic ultrasound (EUS) was performed with an overtube in the same procedure. For safe insertion of the curvilinear array EUS, an overtube with colonoscopy was positioned through the sigmoid as described by Cheng et al. The EUS evaluation evidenced air reverberation in the submucosal layer. The pathological analysis was consistent with PCI's diagnosis. The diagnosis of PCI is usually made by colonoscopy (51.9%), surgery (40.6%), and radiological findings (10.9%). Although the diagnosis can be made by radiological studies, a colorectal EUS and colonoscopy can be made in the same section without radiation and with high precision. As it is a rare disease, there are not enough studies to define the best approach, although colorectal EUS should be preferred for a reliable diagnosis.

2.
World J Gastroenterol ; 27(20): 2495-2506, 2021 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-34092971

RESUMO

Acute post-endoscopic retrograde cholangiopancreatography pancreatitis (PEP) is a feared and potentially fatal complication that can be as high as up to 30% in high-risk patients. Pre-examination measures, during the examination and after the examination are the key to technical and clinical success with a decrease in adverse events. Several studies have debated on the subject, however, numerous topics remain controversial, such as the effectiveness of prophylactic medications and the amylase dosage time. This review was designed to provide an update on the current scientific evidence regarding PEP available in the literature.


Assuntos
Colangiopancreatografia Retrógrada Endoscópica , Pancreatite , Amilases , Colangiopancreatografia Retrógrada Endoscópica/efeitos adversos , Humanos , Pancreatite/etiologia , Fatores de Risco
4.
Arq Gastroenterol ; 57(3): 316-322, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32935747

RESUMO

BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.


Assuntos
Adenoma , Neoplasias Colorretais , Adenoma/diagnóstico , Idoso , Colonoscopia , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer , Fezes , Humanos , Pessoa de Meia-Idade , Sangue Oculto
5.
Arq. gastroenterol ; 57(3): 316-322, July-Sept. 2020. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1131664

RESUMO

ABSTRACT BACKGROUND: Rectal bleeding is the most important symptom of intestinal neoplasia; thus, tests of occult blood detection in stools are widely used for pre neoplastic lesions and colorectal cancer (CRC) screening. OBJECTIVE: Evaluate the accuracy of OC-Sensor quantitative test (Eiken Chemical, Tokyo, Japan) at cut-off 10 µg Hb/g feces (50 ng/mL) in a cohort of subjects that had to undergo diagnostic colonoscopy, and if more than one sample collected in consecutive days would improve the diagnostic accuracy of the test. METHODS: Patients (mean age 56.3±9.7 years) that underwent colonoscopy prospectively randomly received one (1-sample FIT, FIT 1) or two (2-sample FIT, FIT 2) collection tubes. They collected the stool sample before starting colonoscopy preparation. Samples were analyzed by the OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). The performance of FIT 1 and FIT 2 were compared to the colonoscopy findings. RESULTS: Among 289 patients, CRC was diagnosed in 14 (4.8%), advanced adenoma in 37 (12.8%), early adenoma in 71 (24.6%) and no abnormalities in 141 (48.8%). For FIT 1, the sensitivity for CRC was 83.3% (95%CI 36.5-99.1%), for advanced adenoma was 24% (95%CI 10.1-45.5%), with specificity of 86.9% (95%CI 77.3-92.9%). For FIT 2, the sensitivity for CRC was 75% (95%CI 35.6-95.5%), for advanced adenoma was 50% (95%CI 22.3-77.7%), with specificity of 92.9% (95%CI 82.2-97.7%). The positive likelihood ratios were 1.8 (95%CI 0.7-4.4 for FIT 1) and 7.1 (95%CI 2.4-21.4 for FIT 2) for advanced adenoma, and 6.4 (95%CI 3.3-12.3, for FIT 1) and 10.7 (95%CI 3.8-29.8, for FIT 2) for CRC. The negative likelihood ratio were 0.9 (95%CI 0.7-1, for FIT 1) and 0.5 (95%CI 0.3-0.9, for FIT 2) for advanced adenoma, and 0.2 (0.03-1.1, for FIT 1) and 0.3 (0.08-0.9, for FIT 2) for CRC. The differences between FIT 1 and FIT 2 performances were not significant. However, the comparison of the levels of hemoglobin in feces of patients of FIT 1 and FIT 2 showed that the differences between no polyp group and advanced adenoma and CRC were significant. CONCLUSION: The accuracy of OCR Sensor with 10 µg Hb/g feces cut-off was comparable to other reports and two-sample collection improved the detection rate of advanced adenoma, a pre neoplastic condition to prevent CRC incidence.


RESUMO CONTEXTO: Sangramento retal é o sintoma mais importante de neoplasia intestinal; portanto, testes para detecção de sangue oculto nas fezes são amplamente usados para rastreamento de lesões pré-neoplásicas e de câncer colorretal (CCR). OBJETIVO: Avaliar a acurácia do teste quantitativo OC-Sensor (Eiken Chemical, Tokyo, Japan) com o valor de corte de 10 µg Hb/g fezes (50 ng/mL) numa coorte de indivíduos que se submeteram à colonoscopia diagnóstica, e se mais de uma amostra coletada em dias consecutivos melhoraria a acurácia diagnóstica do teste. MÉTODOS: Pacientes (idade média 56,3±9,7 anos) que se submeteram à colonoscopia prospectivamente, randomicamente, receberam tubos de coleta: um (1-amostra FIT, FIT 1), ou dois (2-amostra FIT, FIT 2). Eles coletaram as amostras de fezes antes de iniciar o preparo da colonoscopia. As amostras foram analisadas pelo OC-Auto Micro 80 (Eiken Chemical, Tokyo, Japan). As performances do FIT 1 e do FIT 2 foram comparadas com os achados da colonoscopia. RESULTADOS: Entre 289 pacientes, CCR foi diagnosticado em 14 (4,8%), adenoma avançado em 37 (12,8%), adenoma precoce em 71 (24,6%) e sem anormalidades em 141 (48,8%). Para FIT 1, a sensibilidade para CCR foi 83,3% (95%IC 36,5-99,1%), para adenoma avançado foi 24% (95%IC 10,1-45,5%), com especificidade de 86,9% (95%IC 77,3-92,9%). Para FIT 2, a sensibilidade para CCR foi 75% (95%IC 35,6-95,5%), para adenoma avançado foi 50% (95%IC 22,3-77,7%), com especificidade de 92,9% (95%IC 82,2-97,7%). A razão de verossimilhança positiva foi 1,8 (95%IC 0,7-4,4 para FIT 1) e 7,1 (95%IC 2,4-21,4 para FIT 2) para adenoma avançado, e 6,4 (95%IC 3,3-12,3, para FIT 1) e 10,7 (95%IC 3,8-29,8, para FIT 2) para CCR. A razão de verossimilhança negativa foi 0,9 (95%IC 0,7-1, para FIT 1) e 0,5 (95%IC 0,3-0,9, para FIT 2) para adenoma avançado, e 0,2 (0,03-1,1, para FIT 1) e 0,3 (0,08-0,9, para FIT 2) para CCR. As diferenças de performance entre FIT 1 e FIT 2 não foram significantes. Entretanto, a comparação dos níveis de hemoglobina nas fezes dos pacientes de FIT 1 e FIT 2 mostraram que as diferenças entre sem pólipo e adenoma avançado e CCR foram significantes. CONCLUSÃO: A acurácia do OCR Sensor com valor de corte de 10 µg Hb/g de fezes foi comparável a outras publicações e a coleta de duas amostras melhorou a taxa de detecção de adenoma avançado, lesão pré-neoplásica, para prevenir CCR.


Assuntos
Humanos , Idoso , Neoplasias Colorretais/diagnóstico , Adenoma , Colonoscopia , Detecção Precoce de Câncer , Fezes , Pessoa de Meia-Idade , Sangue Oculto
6.
Endosc Int Open ; 7(11): E1549-E1562, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31723578

RESUMO

Background and study aims Anal examination and video anoscopy (VA) are rarely performed during colonoscopies. The aim of this study is to demonstrate that anal examination and VA provide important information in all routine colonoscopies. Patients and methods A cross-sectional study was conducted on 12,151 patients screened by VA which were performed during routine outpatient colonoscopy between 2006 and 2018. The aspects studied were: normal examination; hemorrhoidal disease; thrombosed hemorrhoids; anal fissure; perianal Crohn's Disease; perianal fistula; condyloma; polyps; neoplasms; stenosis; bleeding. Results Of the colonoscopies performed on 12,151 patients, 9,364 cases (77.06 %) presented some alterations. Internal I degree hemorrhoids (5911 - 48.65 %); internal hemorrhoids of II, III and IV degrees (2362 - 19.44 %); thrombosed hemorrhoids (120 - 0.99 %); bleeding (56 - 0.46 %); fissure (415 - 3.42 %); perianal fistula (42 - 0.35 %); perianal Crohn's Disease (34 - 0.28 %); condylomas (18 - 0.15 %); anal stenosis (30 - 0.25 %); other findings (310 - 2.55 %); polyps (62 - 0.51 %), one of which was adenomatous with high-grade dysplasia; four cases of anal canal neoplasia (0.03 %): two cases of squamous cell carcinoma and two cases of adenocarcinoma. Conclusion The association of routine video anoscopy during colonoscopy improved diagnosis of neoplastic anal lesions, allowed correct classification of the degree of hemorrhoidal disease, helped to confirm the bleeding site and detected other anal pathologies. The main findings were hemorrhoidal diseases, fissures and perianal fistulas. The study suggests that VA should be used in all colonoscopies.

8.
Endosc Int Open ; 6(11): E1322-E1329, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30410952

RESUMO

Background and study aims Obesity is a serious disease, resulting in significant morbidity and mortality. Intragastric balloons (IGBs) have been in use since the 1980s. After the insertion of an IGB, complications such as migration of the device and even severe gastric perforation can occur, requiring laparoscopic surgery. Here, we report three cases of gastric perforation after IGB insertion. In all three cases, the perforation was successfully repaired through an exclusively endoscopic approach.

9.
Obes Surg ; 28(10): 3199-3212, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29951784

RESUMO

BACKGROUND: Laparoscopic greater curvature plication (LGP) has recently emerged as a new bariatric procedure. This surgery provides gastric restriction without resection, which could potentially provide a lower risk alternative, with fewer complications. The real benefit of this technique in the short and long term is unknown. This systematic review aims to compare laparoscopic gastric plication and laparoscopic sleeve gastrectomy for obesity treatment. METHODS: Clinical trials were identified in MEDLINE, Embase, Cochrane, LILACS, BVS, SCOPUS, and CINAHL databases. Comparison of LGP and laparoscopic sleeve gastrectomy (SG) included hospital stay, operative time, loss of hunger feeling, body mass index loss (BMIL), percentage of excess weight loss (%EWL), complications, symptoms in the postoperative period, and comorbidity remission or improvement. RESULTS: This systematic review search included 17,423 records. Eight studies were selected for meta-analysis. There is no difference in operative time, hospital stay, and complications. Patients in the SG group had improved loss of hunger feeling. BMIL was better in the SG group at 12 and 24 months [mean difference (MD) - 2.19, 95% confidence interval (CI) - 3.10 to - 1.28, and MD - 4.59, 95% CI - 5.55 to - 3.63, respectively]. SG showed improved %EWL compared with gastric plication in 3, 6, 12, and 24 months. However, no difference was found in %EWL long-term results (24 and 36 months). Patients who underwent LGP had more sialorrhea. SG showed better results in diabetes remission. CONCLUSIONS: SG showed improved weight loss when compared with LGP, with better satiety, fewer symptoms in the postoperative period, and improved diabetes remission.


Assuntos
Cirurgia Bariátrica , Gastrectomia , Laparoscopia , Obesidade Mórbida/cirurgia , Cirurgia Bariátrica/efeitos adversos , Cirurgia Bariátrica/métodos , Cirurgia Bariátrica/estatística & dados numéricos , Gastrectomia/efeitos adversos , Gastrectomia/métodos , Gastrectomia/estatística & dados numéricos , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Laparoscopia/estatística & dados numéricos , Tempo de Internação , Duração da Cirurgia , Complicações Pós-Operatórias , Resultado do Tratamento , Redução de Peso
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA