Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Int. braz. j. urol ; 50(3): 250-260, May-June 2024. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1558071

RESUMO

ABSTRACT Background: Success rates in endourological procedures, notably percutaneous nephrolithotomy (PCNL) and ureteroscopy (URS), have demonstrated suboptimal outcomes, leading to more reinterventions and radiation exposure. Recently, the use of intraoperative computed tomography (ICT) scans has been hypothesized as a promising solution for improving outcomes in endourology procedures. With this considered, we conducted a comprehensive systematic review and meta-analysis encompassing all available studies that evaluate the impact of the use of intraoperative CT scans on surgical outcomes compared to conventional fluoroscopic-guided procedures. Methods: This systematic review was conducted in accordance with PRISMA guidelines. Multiple databases were systematically searched up to December of 2023. This study aimed to directly compare the use of an ICT scan with the standard non-ICT-guided procedure. The primary endpoint of interest was success rate, and the secondary endpoints were complications and reintervention rates, while radiation exposure was also evaluated. Data extraction and quality assessment were performed following Cochrane recommendations. Data was presented as an Odds ratio with 95%CI across trials and a random-effects model was selected for pooling of data. Results: A comprehensive search yielded 533 studies, resulting in the selection of 3 cohorts including 327 patients (103 ICT vs 224 in non-ICT). Primary outcome was significantly higher in the experimental group versus the control group (84.5% vs 41.4% respectively, 307 patients; 95% CI [3.61, 12.72]; p<0.00001; I2=0). Reintervention rates also decreased from 32.6% in the control to 12.6% in the ICT group (OR 0.34; 95%CI [0.12,0.94]; p =0.04; I2= 48%), whereas complication rates did not exhibit significant differences. Radiation exposure was also significantly reduced in two of the included studies. Conclusion: This meta-analysis highlights a favorable outcome with intraoperative CT scan use in PCNL procedures, showing a considerable increase in SFR when compared to standard fluoroscopy and nephroscopy. Despite limited studies, our synthesis underscores the potential of ICT scans to significantly reduce residual stones and their consequences for endourology patients, as reinterventions and follow-up ionizing radiation studies.

2.
Int Braz J Urol ; 50(3): 250-260, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598828

RESUMO

BACKGROUND: Success rates in endourological procedures, notably percutaneous nephrolithotomy (PCNL) and ureteroscopy (URS), have demonstrated suboptimal outcomes, leading to more reinterventions and radiation exposure. Recently, the use of intraoperative computed tomography (ICT) scans has been hypothesized as a promising solution for improving outcomes in endourology procedures. With this considered, we conducted a comprehensive systematic review and meta-analysis encompassing all available studies that evaluate the impact of the use of intraoperative CT scans on surgical outcomes compared to conventional fluoroscopic-guided procedures. METHODS: This systematic review was conducted in accordance with PRISMA guidelines. Multiple databases were systematically searched up to December of 2023. This study aimed to directly compare the use of an ICT scan with the standard non-ICT-guided procedure. The primary endpoint of interest was success rate, and the secondary endpoints were complications and reintervention rates, while radiation exposure was also evaluated. Data extraction and quality assessment were performed following Cochrane recommendations. Data was presented as an Odds ratio with 95%CI across trials and a random-effects model was selected for pooling of data. RESULTS: A comprehensive search yielded 533 studies, resulting in the selection of 3 cohorts including 327 patients (103 ICT vs 224 in non-ICT). Primary outcome was significantly higher in the experimental group versus the control group (84.5% vs 41.4% respectively, 307 patients; 95% CI [3.61, 12.72]; p<0.00001; I2=0). Reintervention rates also decreased from 32.6% in the control to 12.6% in the ICT group (OR 0.34; 95%CI [0.12,0.94]; p =0.04; I2= 48%), whereas complication rates did not exhibit significant differences. Radiation exposure was also significantly reduced in two of the included studies. CONCLUSION: This meta-analysis highlights a favorable outcome with intraoperative CT scan use in PCNL procedures, showing a considerable increase in SFR when compared to standard fluoroscopy and nephroscopy. Despite limited studies, our synthesis underscores the potential of ICT scans to significantly reduce residual stones and their consequences for endourology patients, as reinterventions and follow-up ionizing radiation studies.


Assuntos
Nefrolitotomia Percutânea , Tomografia Computadorizada por Raios X , Ureteroscopia , Humanos , Tomografia Computadorizada por Raios X/métodos , Nefrolitotomia Percutânea/métodos , Nefrolitotomia Percutânea/efeitos adversos , Ureteroscopia/métodos , Ureteroscopia/efeitos adversos , Cálculos Renais/cirurgia , Cálculos Renais/diagnóstico por imagem , Cuidados Intraoperatórios/métodos , Resultado do Tratamento , Fluoroscopia/métodos , Exposição à Radiação/análise
6.
Clin Genitourin Cancer ; 15(5): 513-519.e5, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28442227

RESUMO

The objective of this study was to compare the surgical, oncological, and functional outcomes of laparoscopic and percutaneous cryoablation for the treatment of small renal masses. A systematic review of the literature was performed through March 2016 using PubMed, Scopus, and Ovid databases. Article selection proceeded according to the search strategy on the basis of the Preferred Reporting Items for Systematic Reviews and Meta-Analyses criteria. Only studies that compared laparoscopic and percutaneous kidney cryoablation were included in the meta-analysis. Eleven retrospective comparative studies were identified and selected for the analysis, including 1725 cases: 804 (46.6%) percutaneous and 921 (53.4%) laparoscopic cryoablations. Percutaneous cryoablation was performed more frequently for posterior tumors (P < .001), whereas laparoscopy was more common for endophytic lesions (P = .01). The length of follow-up was longer for laparoscopy (P < .001). Percutaneous cryoablation was associated with a significantly shorter hospital stay (P < .001). A lower likelihood of residual disease was recorded for laparoscopic (P = .003), whereas tumor recurrence rate favored percutaneous cryoablation (P = .02). The 2 procedures were similar for recurrence-free survival (P = .08), and overall survival (P = .51). No significant difference was found in postoperative estimated glomerular filtration rate (P = .78). Laparoscopic and percutaneous kidney cryoablation offer similar favorable oncological outcomes with minimal effect on renal function. The percutaneous access can offer shorter hospital stay and faster recovery, which can be appealing in an era of cost restraint.


Assuntos
Criocirurgia/métodos , Neoplasias Renais/cirurgia , Laparoscopia/métodos , Feminino , Humanos , Tempo de Internação , Masculino , Análise de Sobrevida , Resultado do Tratamento
7.
JSLS ; 18(3)2014.
Artigo em Inglês | MEDLINE | ID: mdl-25392676

RESUMO

OBJECTIVE: On April 25, 2012, the first laparoscopic cordless ultrasonic device (Sonicision, Covidien, Mansfield, Massachusetts) was used in a clinical setting. We describe our initial experience. METHODS: The cordless device is assembled with a reusable battery and generator on a base hand-piece. It has a minimum and maximum power setting controlled by a single trigger for both coagulation and cutting. A laparoscopic radical nephrectomy was performed on a 56-year-old man with a 7-cm right renal mass. A laparoscopic pelvic lymphadenectomy was performed in a 51-year-old man with high-risk prostate cancer. Data on surgical team satisfaction, operative time, number of activations, and times the laparoscope was removed as a result of plume were collected. RESULTS: The surgical technician successfully assembled the device at the beginning of the cases with verbal instructions from the surgeon. Operative time for nephrectomy was 77 minutes, with 143 total activations (minimum = 86, maximum = 57). The operative time for the pelvic lymphadenectomy was 27 minutes, with 38 total activations (minimum = 27, maximum = 11). One battery was used in each case. The laparoscope was removed twice during the nephrectomy and once during the lymphadenectomy. Surgical staff satisfaction survey results revealed easier and faster assembly, more space in the operating room, ergonomic handle, and comparable cutting/coagulation, weight, and plume generation with other devices (Table 1). [Table: see text]. CONCLUSION: The first clinical application of the pioneering cordless dissector was successfully performed, resulting in surgeons' perceptions of comparable results with other devices of easier and safer use and faster assembly.


Assuntos
Laparoscopia/métodos , Nefrectomia/métodos , Ultrassom/instrumentação , Desenho de Equipamento , Humanos , Duração da Cirurgia
8.
Int Braz J Urol ; 40(1): 23-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24642147

RESUMO

OBJECTIVE: To develop a user friendly system (S.T.O.N.E. Score) to quantify and describe stone characteristics provided by computed axial tomography scan to predict ureteroscopy outcomes and to evaluate the characteristics that are thought to affect stone free rates. MATERIALS AND METHODS: The S.T.O.N.E. score consists of 5 stone characteristics: (S) ize, (T)opography (location of stone), (O)bstruction, (N)umber of stones present, and (E)valuation of Hounsfield Units. Each component is scored on a 1-3 point scale. The S.T.O.N.E. Score was applied to 200 rigid and flexible ureteroscopies performed at our institution. A logistic model was applied to evaluate our data for stone free rates (SFR). RESULTS: SFR were found to be correlated to S.T.O.N.E. Score. As S.T.O.N.E. Score increased, the SFR decreased with a logical regression trend (p < 0.001). The logistic model found was SFR=1/(1+e^(-z)), where z=7.02-0.57•Score with an area under the curve of 0.764. A S.T.O.N.E. Score ≤ 9 points obtains stone free rates > 90% and typically falls off by 10% per point thereafter. CONCLUSIONS: The S.T.O.N.E. Score is a novel assessment tool to predict SFR in patients who require URS for the surgical therapy of ureteral and renal stone disease. The features of S.T.O.N.E. are relevant in predicting SFR with URS. Size, location, and degree of hydronephrosis were statistically significant factors in multivariate analysis. The S.T.O.N.E. Score establishes the framework for future analysis of the treatment of urolithiasis.


Assuntos
Tomografia Computadorizada por Raios X/métodos , Ureteroscopia/métodos , Urolitíase/diagnóstico por imagem , Adulto , Intervalo Livre de Doença , Reações Falso-Positivas , Feminino , Humanos , Litotripsia/métodos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Urolitíase/patologia , Urolitíase/terapia
9.
Urology ; 83(4): 738-44, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24486000

RESUMO

OBJECTIVE: To evaluate the association of preoperative noncontrast computed tomography stone characteristics, laser settings, and stone composition with cumulative holmium:yttrium-aluminum-garnet (Ho:YAG) laser time/energy. MATERIALS AND METHODS: We retrospectively reviewed patients who underwent semirigid/flexible ureteroscopy and Ho:YAG laser lithotripsy (200 or 365 µm laser fiber; 0.8-1.0 J energy; and 8-10 Hz rate) at 2 tertiary care centers (April 2010-May 2012). Studied parameters were as follows: patient's characteristics; stone characteristics (location, burden, hardness, and composition); total laser time and energy; and surgical outcomes. RESULTS: One hundred patients met our inclusion criteria. Mean stone size was 1.01 ± 0.42 cm and volume 0.33 ± 0.04 cm(3). Mean stone radiodensity was 990 ± 296 HU, and Hounsfield units density 13.8 ± 6.0 HU/mm. All patients were considered stone free. Stone size and volume had a significant positive correlation with laser energy (R = 0.516, P <.001; R = 0.621, P <.001) and laser time (R = 0.477, P <.001; R = 0.567, P <.001). When controlling for stone size, only the correlation between HU and laser time was significant (R = 0.262, P = .011). In the multivariate analysis, with exception of stone composition (P = .103), all parameters significantly increased laser energy (R(2) = 0.524). Multivariate analysis revealed a positive significant association of laser time with stone volume (P <.001) and Hounsfield units density (P <.001; R(2) = 0.512). In multivariate analysis for laser energy, only calcium phosphate stones required less energy to fragment compared with uric acid stones. No significant differences were found in the multivariate laser time model. CONCLUSION: Ho:YAG laser cumulative energy and total time are significantly affected by stone dimensions, hardness location, fiber size, and power. Kidney location, laser fiber size, and laser power have more influence on the final laser energy than on the total laser time. Calcium phosphate stones require less laser energy to fragment.


Assuntos
Alumínio/química , Hólmio/química , Litotripsia a Laser/métodos , Ureteroscopia , Ítrio/química , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/terapia , Lasers , Lasers de Estado Sólido , Análise Multivariada , Estudos Retrospectivos , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Cálculos Ureterais/diagnóstico por imagem , Cálculos Ureterais/terapia
10.
Int. braz. j. urol ; 40(1): 23-29, Jan-Feb/2014. tab, graf
Artigo em Inglês | LILACS | ID: lil-704173

RESUMO

Objective: To develop a user friendly system (S.T.O.N.E. Score) to quantify and describe stone characteristics provided by computed axial tomography scan to predict ureteroscopy outcomes and to evaluate the characteristics that are thought to affect stone free rates. Materials and Methods: The S.T.O.N.E. score consists of 5 stone characteristics: (S)ize, (T)opography (location of stone), (O)bstruction, (N)umber of stones present, and (E)valuation of Hounsfield Units. Each component is scored on a 1-3 point scale. The S.T.O.N.E. Score was applied to 200 rigid and flexible ureteroscopies performed at our institution. A logistic model was applied to evaluate our data for stone free rates (SFR). Results: SFR were found to be correlated to S.T.O.N.E. Score. As S.T.O.N.E. Score increased, the SFR decreased with a logical regression trend (p < 0.001). The logistic model found was SFR=1/(1+e.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Ureteroscopia/métodos , Urolitíase , Intervalo Livre de Doença , Reações Falso-Positivas , Modelos Logísticos , Litotripsia/métodos , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Urolitíase/patologia , Urolitíase/terapia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA