J Perinat Med ; 52(6): 665-670, 2024 Jul 26.
Artigo em Inglês | MEDLINE | ID: mdl-38758017

RESUMO

OBJECTIVES: To identify factors associated with poor prognoses in newborns with a prenatal diagnosis of gastroschisis in eight hospitals in Bogota, Colombia, from 2011 to 2022. METHODS: A multi-center retrospective case-control study was conducted on newborns with gastroschisis in eight hospitals in Bogota, Colombia. Poor prognosis was defined as the presence of sepsis, intestinal complications, or death. RESULTS: The study included 101 patients. Preterm newborns under 32 weeks had a poor neonatal prognosis (OR 6.78 95 % CI 0.75-319). Oligohydramnios (OR 4.95 95 % CI 1.15-21.32) and staged closure with silo (OR 3.48; 95 % CI 1.10-10.96) were risk factors for neonatal death, and intra-abdominal bowel dilation of 20-25 mm was a factor for the development of intestinal complications (OR 3.22 95 % CI 1.26-8.23). CONCLUSIONS: Intra-abdominal bowel dilation between 20 and 25 mm was associated with intestinal complications, while oligohydramnios was associated with the risk of perinatal death, requiring increased antenatal surveillance of fetal wellbeing. Management with primary reduction when technically feasible is recommended in these infants, considering that the use of silos was associated with higher mortality.


Assuntos
Gastrosquise , Humanos , Recém-Nascido , Colômbia/epidemiologia , Gastrosquise/diagnóstico , Gastrosquise/diagnóstico por imagem , Gastrosquise/epidemiologia , Gastrosquise/mortalidade , Feminino , Estudos Retrospectivos , Gravidez , Estudos de Casos e Controles , Prognóstico , Masculino , Fatores de Risco , Oligo-Hidrâmnio/epidemiologia , Oligo-Hidrâmnio/diagnóstico , Ultrassonografia Pré-Natal , Adulto , Recém-Nascido Prematuro
2.
Rev. chil. obstet. ginecol. (En línea) ; 89(2): 109-115, abr. 2024.
Artigo em Espanhol | LILACS | ID: biblio-1559725

RESUMO

Introducción y objetivo: Explorar las estrategias de prevención de la preeclampsia que se han propuesto a lo largo de la historia. Método: Revisión narrativa de la literatura sobre la evidencia científica histórica disponible entre 2016 y 2023 acerca de la aspirina y otras estrategias de prevención de la preeclampsia, en bases de datos bibliográficas computarizadas de estudios publicados en revistas indexadas. Resultados: Varios estudios confirman la efectividad de la aspirina para prevenir la preeclampsia en población de alto riesgo, siendo un medicamento con bajo riesgo de complicaciones, con mayor evidencia de efectividad si se inicia antes de las 16 semanas de gestación y con un aparente efecto dependiente de la dosis. Intervenciones como la disminución del consumo de sal, el reposo en cama, la suplementación con ácidos grasos, antioxidantes, L-arginina, zinc o magnesio, y el uso de diuréticos o de inhibidores de la bomba de protones, no han mostrado su utilidad en la prevención de la preeclampsia. Conclusiones: La aspirina a dosis baja es un medicamento seguro en el embarazo y efectivo para prevenir la preeclampsia en población de alto riesgo. Es la estrategia de prevención más ampliamente estudiada a lo largo de la historia para la disfunción endotelial durante la gestación.


Introduction and objective: To explore the different prevention strategies for preeclampsia that have been proposed throughout the history. Method: A narrative review of the historical, scientific evidence available between 2016 and 2021 on aspirin and other preeclampsia prevention strategies in computerized bibliographic databases of studies published in indexed journals. Results: Several studies confirm the effectiveness of aspirin to prevent preterm preeclampsia in high-risk populations, considering this as a safe drug with low risk of complications, with greater evidence of effectiveness when started before 16 weeks of gestation and apparently with a dose-dependent effect. Interventions such as reducing salt intake, bed rest, supplementation with fatty acids, antioxidants, L-arginine, zinc, magnesium, the use of diuretics or proton pump inhibitors have not shown its usefulness in the prevention of high risk preeclampsia patients. Conclusions: Low-dose aspirin is a safe drug in pregnancy and is effective to prevent preeclampsia in high-risk populations. Is the most widely studied throughout history prevention strategy for endothelial dysfunction during pregnancy.


Assuntos
Humanos , Feminino , Gravidez , Pré-Eclâmpsia/prevenção & controle , Prevenção Primária , Gravidez de Alto Risco
3.
J Clin Ultrasound ; 52(2): 189-200, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37994115

RESUMO

OBJECTIVE: To describe the texture characteristics in several anatomical structures within fetal ultrasound images by applying an image segmentation technique through an application developed in MATLAB mathematical processing software. METHODS: Prospective descriptive observational study with an analytical component. 2D fetal ultrasound images were acquired in patients admitted to the Maternal Fetal Medicine Unit of the Hospital de San José, Bogotá-Colombia. These images were loaded into the developed application to carry out the segmentation and characterization stages by means of 23 numerical texture descriptors. The data were analyzed with central tendency measures and through an embedding process and Euclidean distance. RESULTS: Forty ultrasound images were included, characterizing 54 structures of the fetal placenta, skull, thorax, and abdomen. By embedding the descriptors, the differentiation of biologically known structures as distinct was achieved, as well as the non-differentiation of similar structures, evidenced using 2D and 3D graphs and numerical data with statistical significance. CONCLUSION: The texture characterization of the labeled structures in fetal ultrasound images through the numerical descriptors allows the accurate discrimination of these structures.


Assuntos
Feto , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Ultrassonografia Pré-Natal/métodos , Ultrassonografia , Feto/diagnóstico por imagem , Placenta , Estudos Prospectivos , Processamento de Imagem Assistida por Computador/métodos
4.
J Clin Ultrasound ; 52(2): 152-162, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37990792

RESUMO

OBJECTIVE: To establish nomograms for linear measurements of the frontal and occipital horns of the lateral ventricle and their relationship, in pregnant patients between 18 and 40 weeks of gestation and having attended 2 units of Maternal Fetal Medicine in Bogotá-Colombia. METHODOLOGY: A descriptive cross-sectional study with an analytical component was carried out on pregnant patients who utilized the ultrasound services at 2 Maternal-Fetal Medicine units in Bogotá, between 18 and 40 weeks of pregnancy who underwent measurement. From the anterior and posterior horns of the lateral ventricles, the fronto-occipital ratio was calculated at each gestational week, and nomograms were created for each of these variables. RESULTS: Nine hundred and seventy-eight patients were included in the study. The distance of the frontal horns ranged between 6.9 and 51.6 mm with a mean of 19.1 ± 5.8 mm; that of the occipital horns had a measurement between 8.7 and 53 mm with a mean of 28, 1 ± 8.9 mm; on the other hand, the fronto-occipital ratio (FOR) yielded a mean of 0.365 ± 0.067 (0.136-0.616) without bearing any relation to gestational age. The trend of normal values for the studied population is displayed, plotted in percentile curves and nomograms for each gestational age. CONCLUSION: The measurement of the frontal and occipital horns, and the calculation of the fronto-occipital relationship is technically possible between 18 and 40 weeks, finding that the anterior and posterior horns have a positive linear relationship with gestational age. Contrarily, the FOR does not correlate with the gestational age, it was possible to establish a table of percentiles that allows determining the normal values for these measurements during pregnancy.


Assuntos
Feto , Perinatologia , Gravidez , Feminino , Humanos , Colômbia , Valores de Referência , Estudos Transversais , Feto/diagnóstico por imagem , Idade Gestacional , Ultrassonografia Pré-Natal
5.
Ginecol. obstet. Méx ; 92(2): 69-84, ene. 2024. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1557857

RESUMO

Resumen OBJETIVO: Determinar si la exposición al ondansetrón en el primer trimestre del embarazo se asocia, en general, con mayor riesgo de malformaciones orofaciales, cardiopatías congénitas, defectos del septo interventricular, de labio o paladar hendidos. MÉTODOLOGÍA: Revisión sistemática y metanálisis de estudios aleatorizados, cohortes y casos y controles publicados en las bases de datos de PubMed, EMBASE y LILACS. RESULTADOS: Se incluyeron 15 estudios: 11 de cohorte y 4 de casos y controles, con 245,679 mujeres expuestas al ondansetrón en el primer trimestre del embarazo. No se encontró una asociación estadísticamente significativa con malformaciones congénitas en general (RM 1.1; IC95%: 0.99-1.22; I2: 72%), con cardiopatías congénitas (RM 1.05; IC95%: 0.95-1.19; I2: 78%) y con comunicación interventricular (RM 1.2; IC95%: 0.97-1.45; I2: 85%). Se encontró un pequeño aumento en el riesgo de defectos orofaciales en general (RM 1.17; IC95%: 1.04-1.32; I2:0%), no se encontró un riesgo mayor de defecto de labio (RM 1.01; IC95%: 0.84-1.21; I2%: 0%) ni de paladar hendido (RM 1.16; IC95%: 0.9-1.5; I2: 31%). CONCLUSIÓN: Los resultados muestran que el tratamiento con ondansetrón en el primer trimestre del embarazo no se asocia con un aumento de malformaciones congénitas en general, ni con un incremento de cardiopatías, labio o paladar hendido, pero sí con incremento leve del riesgo de malformaciones orofaciales.


Abstract OBJECTIVE: To determine whether ondansetron exposure in the first trimester is associated with an increased risk of any congenital malformations. As secondary outcomes, determine if it is associated with a higher overall risk of congenital heart disease, interventricular septal defects, orofacial malformations, cleft lip defect (with or without palate) or cleft palate. METHODOLOGY: A systematic review with meta-analysis was carried out. The search was carried out in the following databases: PUBMED, EMBASE and LILACS, randomized studies, cohorts and cases and controls were chosen. RESULTS: 15 studies were included, 11 cohort studies and four case-control studies, with 245,679 women exposed to ondansetron in the first trimester. No statistically significant association was found with overall congenital malformations (OR, 1.1; 95%, CI 0.99-1.22 I2: 72%), nor with congenital heart diseases (OR, 1.05; 95%, CI 0.95-1.19 I2: 78%) not with ventricular septal defects (OR, 1.2 95% CI 0.97 - 1.45 I2: 85%). A small increased risk was found for overall orofacial defects (OR, 1.17 95% CI 1.04 - 1.32 I2:0%), no increased risk was found for lip defect (with or without palate) (OR, 1.01 CI 95% 0.84 -1.21 I2%: 0%) or cleft palate (OR, 1.16 95% CI 0.9 - 1.5 I2: 31%). CONCLUSION: The results show that the use of ondansetron in the first trimester is not associated with an increase in overall congenital malformations, nor with an increase in heart disease, cleft lip and/or palate, but there is a slight increase in the risk of orofacial malformations.

6.
Fetal Diagn Ther ; 50(6): 446-453, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37536303

RESUMO

INTRODUCTION: The optimal approach and therapy method for the acardiac twin with a reverse arterial perfusion sequence has not yet been established. The aim of this study was to determine the clinical practice patterns among international fetal therapy units in their management of these cases. METHODS: A survey was sent to fetal centers across the world via email between December 2020 and December 2021. RESULTS: Responses were obtained from 77% contacted centers. The most frequent ultrasound variables used in the evaluation of twin reverse arterial perfusion sequence include echocardiographic assessment of the pump twin and umbilical artery Doppler waveforms in the acardiac and pump twins, in 90% and 80% of the centers, respectively. Most centers in Europe and Latin America propose an in utero intervention in all cases. Most centers in Europe and Latin America prefer interstitial laser ablation, whereas radiofrequency ablation (RFA) is preferred in North America. The earliest gestational age for an intervention is on mean 13 weeks in Europe, which is earlier than the other geographic areas (p = 0.001). CONCLUSIONS: Most centers agreed that antenatal evaluation should include echocardiography along with the UA Doppler waveform measurements, and the most frequently used interventions were interstitial laser ablation or RFA at a median between 14 and 26 weeks.


Assuntos
Transfusão Feto-Fetal , Cardiopatias Congênitas , Gêmeos Unidos , Gravidez , Feminino , Humanos , Lactente , Transfusão Feto-Fetal/diagnóstico por imagem , Transfusão Feto-Fetal/cirurgia , Gêmeos , Doenças em Gêmeos , Perfusão
7.
Ginecol. obstet. Méx ; 91(10): 736-752, ene. 2023.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1557819

RESUMO

Resumen ANTECEDENTES: Existe interés creciente en los efectos de la vitamina D en el embarazo y en la función placentaria, homeostasis de la glucosa, infección y respuesta inflamatoria, además de la asociación de su deficiencia con enfermedades de alto riesgo obstétrico. OBJETIVO: Identificar los aspectos relevantes conocidos y controvertidos del déficit de vitamina D y de su suplementación en pacientes con alto riesgo obstétrico que permitan aportarle al lector herramientas para la toma de decisiones en la práctica clínica. METODOLOGÍA: Se llevó a cabo una revisión de la bibliografía registrada en las bases de datos de MEDLINE vía PubMed, EBSCO y OVID del 2016 al 2022. Se consultaron artículos publicados en inglés y español, con los términos MeSH "Vitamin D", "preeclampsia", "premature birth", "diabestes, gestational" y "fetal growth retardation". RESULTADOS: La búsqueda inicial arrojó 685 artículos de los que se descartaron 364 por falta de pertinencia, 248 por falta del recurso completo y 44 por duplicaciones. De acuerdo con el objetivo planteado, al final quedaron 29 artículos que se complementaron con 55 textos clásicos encontrados en una búsqueda manual para contextualización de la revisión. CONCLUSIONES: La evidencia respecto de la asociación entre deficiencia de vitamina D y pobres desenlaces obstétricos, en términos de tasas de preeclampsia, parto pretérmino, diabetes gestacional y restricción del crecimiento fetal no es concluyente. Sin embargo, el análisis de los estudios mencionados muestra una relación entre el déficit de vitamina D y el aumento del riesgo, desenlaces impactantes y consistentes con el riesgo de resultar con diabetes gestacional.


Abstract BACKGROUND: There is increasing interest in the effects of vitamin D in pregnancy and on placental function, glucose homeostasis, infection and inflammatory response, and the association of vitamin D deficiency with high-risk obstetric conditions. OBJECTIVE: To identify the relevant known and controversial aspects of vitamin D deficiency and its supplementation in patients at high obstetric risk, in order to provide the reader with decision-making tools for clinical practice. METHODOLOGY: A review of the literature registered in the MEDLINE databases via PubMed, EBSCO and OVID from 2016 to 2022 was performed. Articles published in English and Spanish were included using the MeSH terms "vitamin D", "pre-eclampsia", "preterm birth", "gestational diabetes" and "fetal growth retardation". RESULTS: The initial search yielded 685 articles, of which 364 were discarded for lack of relevance, 248 for lack of complete source and 44 for duplication. In accordance with the stated objective, 29 articles remained at the end, which were supplemented by 55 classic texts found in a manual search to contextualise the review. CONCLUSIONS: The evidence for an association between vitamin D deficiency and poor obstetric outcomes in terms of rates of pre-eclampsia, preterm birth, gestational diabetes and fetal growth restriction is inconclusive. However, analysis of the above studies shows an association between vitamin D deficiency and increased risk, with striking results consistent with the risk of gestational diabetes.

8.
Rev. MED ; 30(1): 7-10, jun. 2022.
Artigo em Espanhol | LILACS | ID: biblio-1535350

Assuntos
Humanos , Feto
9.
Ginecol. obstet. Méx ; 90(8): 655-663, ene. 2022. tab, graf
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1404957

RESUMO

Resumen OBJETIVO: Conocer los aportes de la resonancia magnética, como estudio complementario al ultrasonido, en el diagnóstico de malformaciones fetales en el sistema nervioso central, musculoesquelético y tórax en dos unidades de Medicina Materno Fetal. MATERIALES Y MÉTODOS: Estudio retrospectivo, observacional y comparativo, de corte transversal, efectuado con base en la revisión de las historias clínicas registradas durante tres años de pacientes con más de 18 semanas de embarazo remitidas a la Unidad de Medicina Materno Fetal del Hospital San José y la Clínica Colsubsidio por alguna malformación estructural fetal identificada en el sistema nervioso central, musculoesquelético y tórax diagnosticada con base en la ultrasonografía. RESULTADOS: Se revisaron 109 historias clínicas de pacientes embarazadas con fetos con diagnóstico de malformación congénita por ultrasonido. Las indicaciones más frecuentes fueron: anormalidades en el sistema nervioso central en 61.5%; hidrocefalia no comunicante en 36.6% por ultrasonido y 21% por resonancia magnética, seguida de las del tórax con 40.4% por ultrasonido y 36.7% por resonancia magnética y malformaciones del sistema musculoesquelético con 20.1% por ultrasonido y 2.8% por resonancia magnética. La concordancia diagnóstica entre el ultrasonido y el diagnóstico posnatal fue del 66% y el de la resonancia magnética de 76%. En comparación con el ultrasonido inicial la resonancia magnética aumentó la frecuencia de diagnóstico de malformación fetal. CONCLUSIÓN: La resonancia magnética, complementaria al diagnóstico por ultrasonido de malformaciones congénitas, fue más notable en los sistemas nervioso central y musculoesquelético donde permitió mejorar la caracterización de las alteraciones detectadas en el ultrasonido.


Abstract OBJECTIVE: To know the contributions of magnetic resonance imaging, as a complementary study to ultrasound, in the diagnosis of fetal malformations in the central nervous system, musculoskeletal and thorax in two units of Maternal Fetal Medicine. MATERIALS AND METHODS: Retrospective, observational and comparative cross-sectional study, based on the review of medical records recorded during three years of patients with more than 18 weeks of pregnancy referred to the Maternal Fetal Medicine Unit of Hospital San José and Clínica Colsubsidio, for any fetal structural malformation identified in the central nervous system, musculoskeletal and thorax diagnosed based on ultrasonography. RESULTS: We reviewed 109 clinical histories of pregnant patients with fetuses diagnosed with congenital malformation by ultrasound. The most frequent indications were abnormalities of the central nervous system in 61.5%: non-communicating hydrocephalus in 36.6% by ultrasound and 21% by MRI, followed by those of the thorax with 40.4% by ultrasound and 36.7 by MRI and malformations of the musculoskeletal system 20.1% by ultrasound and 2.8% by MRI. The diagnostic agreement between ultrasound and postnatal diagnosis was 66% and that of MRI was 76%. Compared to initial ultrasound, MRI increased the frequency of diagnosis of fetal malformation. CONCLUSION: MRI, complementary to ultrasound diagnosis of congenital malformations, was more notable in the central nervous and musculoskeletal systems where it allowed improving the characterization of the alterations detected by ultrasound.

10.
Ginecol. obstet. Méx ; 90(8): 664-681, ene. 2022.
Artigo em Espanhol | LILACS-Express | LILACS | ID: biblio-1404958

RESUMO

Resumen OBJETIVO: Ofrecer al lector información amplia y suficiente acerca de este síndrome, con hincapié en el reconocimiento del daño multiorgánico fetal, que permita darle herramientas para establecer el diagnóstico oportuno y disminuir la morbilidad y mortalidad fetal y neonatal. METODOLOGÍA: Estudio retrospectivo con base en la búsqueda en las bases de datos de PubMed, EBSCO y Ovid de 2016 a 2021 de artículos de revisión, investigaciones originales, guías de práctica clínica y protocolos. Además, artículos clásicos y los correspondientes a búsquedas manuales para lograr la contextualización de los puntos tratados. RESULTADOS: Cuando la infección llega al feto, se despliega una respuesta proinflamatoria con secreción de citocinas, que son la base para el diagnóstico de síndrome de respuesta inflamatoria fetal. Cuando esta respuesta a la infección es desregulada, termina por generar un daño multiorgánico que puede ser reconocido por medio de herramientas no invasivas, como el ultrasonido fetal avanzado. Este reconocimiento permite iniciar la atención oportuna a fin de reducir las tasas de morbilidad y mortalidad perinatal. CONCLUSIÓN: La infección microbiana de la cavidad amniótica y del feto, con la generación subsecuente del síndrome de respuesta inflamatoria fetal, se asocia con daño multiorgánico que puede reconocerse en el ultrasonido avanzado y lograr la atención óptima y mejores desenlaces perinatales.


Abstract OBJECTIVE: To provide the reader with ample and sufficient information about this syndrome, with emphasis on the recognition of fetal multiorgan damage, to provide tools to establish a timely diagnosis and reduce fetal and neonatal morbidity and mortality. METHODOLOGY: Retrospective study based on the search in PubMed, EBSCO and Ovid databases from 2016 to 2021 of review articles, original research, practice guidelines and protocols. In addition, classic articles and those corresponding to manual searches to achieve contextualization of the points discussed. RESULTS: When infection reaches the fetus, a proinflammatory response with cytokine secretion unfolds, which are the basis for the diagnosis of fetal inflammatory response syndrome. When this response to infection is deregulated, it ends up generating multiorgan damage that can be recognized by means of noninvasive tools, such as advanced fetal ultrasound. This recognition allows initiating timely care in order to reduce perinatal morbidity and mortality rates. CONCLUSION: Microbial infection of the amniotic cavity and fetus, with subsequent generation of fetal inflammatory response syndrome, is associated with multiorgan damage that can be recognized on advanced ultrasound and achieve optimal care and better perinatal outcomes.

SELEÇÃO DE REFERÊNCIAS