Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Pediatr ; 261: 113585, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37354991

RESUMO

We evaluated the association between left cardiac 3-dimensional echocardiographic parameters and brain injury in a single-center prospective study of neonates with neonatal encephalopathy. On day 2 of life, neonates with brain injury had greater left ventricle end-diastolic and stroke volume but also greater peak global circumferential strain detected by 3-dimensional echocardiogram.


Assuntos
Lesões Encefálicas , Ecocardiografia Tridimensional , Disfunção Ventricular Esquerda , Recém-Nascido , Humanos , Lactente , Função Ventricular Esquerda , Estudos Prospectivos , Ecocardiografia/métodos , Ecocardiografia Tridimensional/métodos , Volume Sistólico , Ventrículos do Coração/diagnóstico por imagem , Lesões Encefálicas/complicações , Lesões Encefálicas/diagnóstico por imagem , Disfunção Ventricular Esquerda/diagnóstico por imagem
2.
J Pediatr ; 257: 113369, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36868306

RESUMO

OBJECTIVES: To compare trends in the anterior cerebral artery (ACA) Doppler markers of vascular flow for neonates with a congenital heart defect (CHD) with and without diastolic systemic steal during the first 7 days of life. METHODS: Prospective study recruiting newborns (≥35 weeks of gestation) with a CHD. Doppler ultrasound and echocardiography were performed daily from day 1 to 7. The cohort was divided into the presence/absence of holo-diastolic retrograde flow in the postductal aorta ("retrograde") on the last-available echocardiogram. Data extractors were masked to retrograde status. Mixed effect models (random slope/intercept) were constructed using RStudio. RESULTS: We enrolled 38 neonates with CHD. Retrograde aortic flow was present on the last echocardiogram in 23 (61%). Peak systolic velocity and mean velocity increased significantly over time, independent of retrograde status. However, having a "retrograde" flow status conferred a significant decrease over time of their ACA-end-diastolic velocity (ß = -5.75 cm/s, 95% CI -8.38 to -3.12, P < .001, when compared with the nonretrograde group), and a significant increase in the ACA resistive (ß = 0.16, 95% CI 0.10-0.22, P < .001) and pulsatility (ß = 0.49, 95% CI 0.28-0.69, P < .001) indexes. No subject presented retrograde diastolic flow in the ACA. CONCLUSIONS: In neonates with CHD in the first week of life, infants with echocardiographic signs of systemic diastolic steal within the pulmonary circulation have Doppler signs of cerebrovascular steal in the ACA.


Assuntos
Circulação Cerebrovascular , Cardiopatias Congênitas , Lactente , Recém-Nascido , Humanos , Estudos Prospectivos , Velocidade do Fluxo Sanguíneo , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia Doppler
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA